Products

6065 products

  • LUNAR DOWNLIGHT 20W

    LUNAR DOWNLIGHT 20W

    Key Features LED Recessed Downlight. Surge upto 2.5 KV. High voltage cut-off. True-Isolated.

    Rs. 364.33

  • LUNAR DOWNLIGHT 5W

    LUNAR DOWNLIGHT 5W

    Features: 85% energy saving over GLS Wide voltage range 220-240V, 50Hz Surge protection ≤ 4.0 KV Power factor ≥ 0.95, CRI-80 High lumen output Provide high brightness Exceedingly high life & lasts up to 25000 hours About: Brand - LEDEL Wattage - 5W Color Temperature - Cool Day Light 6500K  Product Type - Indoor Warranty - 1 Year Made in India

    Rs. 134.23

  • LUNAR DOWNLIGHT 5W

    LUNAR DOWNLIGHT 5W

    Power 20 W Light Color Warm White Color Temperature 6500K Shape Round Material Polycarbonate Mounting Type Recessed Mounted Country of Origin Made in India Availability In Stock

    Rs. 134.23

  • LV-N11MN KEYENCE

    LV-N11MN KEYENCE

    Specifications Model LV-N11MN Type Monitor output Output NPN Cable/connector Cable Main/Expansion unit Main unit I/O Control outputs 1 output External input 1 input Monitor output 1 output Output selection LIGHT-ON/DARK-ON (switch-selectable) Timer function Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,Timer duration selectable: 1 ms to 9,999 ms,Maximum error against the setting value: ±10% max. Control outputs NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less(Multiple connections) 1 output max: 20 mA or less Response time 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 Monitor output 1 to 5 V voltage output; load resistance 10 kΩ or more; repeat precision ±0.5% of F.S.;response time: 1 ms (HIGH SPEED, FINE, TURBO), 1.2 ms (SUPER), 1.8 ms (ULTRA), 4.2 ms (MEGA) External input Input time 2 ms (ON)/20 ms (OFF) or more*2 Number of interferenceprevention units Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3 Case size H 32.6 mm × W 9.8 mm × L 78.7 mm Unit expansion Up to 17 units can be connected in total (two-output type is treated as two units) Protection circuit Reverse polarity protection, Over-current protection, Surge absorber Rating Power voltage 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS Powerconsumption Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*4Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*4Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)*5 Environmental resistance Ambient temperature -20 to +55 °C (No freezing)*6 Relative humidity 35 to 85 % RH (No condensation) Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions Material Cable PVC Case Main unit and cover material: Polycarbonate Weight Approx. 75 g *1 80 µs cannot be selected when the LV-S31/S62/S63 is connected*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.*3 These numbers double when "DOUBLE" is selected.*4 Increases 30 mW (1 mA) for High Speed mode.*5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.*6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.One or two more units connected: -20 °C to +55 °C ; 3 to 10 more units connected: -20 °C to +50 °C; 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units.

    Rs. 12,733.00

  • LV-N11N KEYENCE

    LV-N11N KEYENCE

    Specifications Model LV-N11N Type 2 output Output NPN Cable/connector Cable Main/Expansion unit Main unit I/O Control outputs 2 output External input 1 input Monitor output None Output selection LIGHT-ON/DARK-ON (switch-selectable) Timer function Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,Timer duration selectable: 1 ms to 9,999 ms,Maximum error against the setting value: ±10% max. Control outputs NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less(Multiple connections) 1 output max: 20 mA or less Response time 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 Monitor output - External input Input time 2 ms (ON)/20 ms (OFF) or more*2 Number of interferenceprevention units Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3 Case size H 32.6 mm × W 9.8 mm × L 78.7 mm Unit expansion Up to 17 units can be connected in total (two-output type is treated as two units) Protection circuit Reverse polarity protection, Over-current protection, Surge absorber Rating Power voltage 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS Powerconsumption Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*4Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*4Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)*5 Environmental resistance Ambient temperature -20 to +55 °C (No freezing)*6 Relative humidity 35 to 85 % RH (No condensation) Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions Material Cable PVC Case Main unit and cover material: Polycarbonate Weight Approx. 75 g *1 80 µs cannot be selected when the LV-S31/S62/S63 is connected*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.*3 These numbers double when "DOUBLE" is selected.*4 Increases 30 mW (1 mA) for High Speed mode.*5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.*6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.One or two more units connected: -20 °C to +55 °C ; 3 to 10 more units connected: -20 °C to +50 °C; 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units. Data Sheet (PDF) Specifications Model LV-N11N Type 2 output Output NPN Cable/connector Cable Main/Expansion unit Main unit I/O Control outputs 2 output External input 1 input Monitor output None Output selection LIGHT-ON/DARK-ON (switch-selectable) Timer function Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,Timer duration selectable: 1 ms to 9,999 ms,Maximum error against the setting value: ±10% max. Control outputs NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less(Multiple connections) 1 output max: 20 mA or less Response time 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 Monitor output - External input Input time 2 ms (ON)/20 ms (OFF) or more*2 Number of interferenceprevention units Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3 Case size H 32.6 mm × W 9.8 mm × L 78.7 mm Unit expansion Up to 17 units can be connected in total (two-output type is treated as two units) Protection circuit Reverse polarity protection, Over-current protection, Surge absorber Rating Power voltage 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS Powerconsumption Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*4Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*4Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)*5 Environmental resistance Ambient temperature -20 to +55 °C (No freezing)*6 Relative humidity 35 to 85 % RH (No condensation) Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions Material Cable PVC Case Main unit and cover material: Polycarbonate Weight Approx. 75 g *1 80 µs cannot be selected when the LV-S31/S62/S63 is connected*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.*3 These numbers double when "DOUBLE" is selected.*4 Increases 30 mW (1 mA) for High Speed mode.*5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.*6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.One or two more units connected: -20 °C to +55 °C ; 3 to 10 more units connected: -20 °C to +50 °C; 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units.

    Rs. 12,132.00

  • LV-NH100 KEYENCE

    LV-NH100 KEYENCE

    Out of stock

    Specifications Model LV-NH100 Type Area thrubeam, High performance FDA (CDRH) Part 1040.10 Class 1 Laser Product IEC 60825-1 Light source Visible red semiconductor laser, Wavelength: 660 nm Detectingdistance MEGA 2000 mm(Detecting area: 10 mm) ULTRA SUPER TURBO FINE HSP Environmental resistance Ambient temperature -10 to +55 °C (No freezing) Relative humidity 35 to 85 % RH (No condensation) Material Case Glass reinforced plastic Lens cover Transmitter: Glass, Receiver: Polyarylate Weight Approx. 75 g

    Out of stock

    Rs. 0.00

  • LV-NH42 KEYENCE

    LV-NH42 KEYENCE

    Specifications Model LV-NH42 Type Long-distance FDA (CDRH) Part 1040.10 Class 1 IEC 60825-1 Light source Visible semiconductor laser, Wavelength: 660 nm Detectingdistance MEGA 1200 mm ULTRA 1000 mm SUPER 750 mm TURBO 500 mm FINE 250 mm HSP 200 mm Environmental resistance Ambient temperature -10 to +55°C (No freezing) Relative humidity 35 to 85% RH (No condensation) Material Case Glass-reinforced plastic Lens cover Polyarylate Weight Approx. 65 g Data Sheet (PDF)

    Rs. 16,697.00

  • LWH-0400 Linear Position Transducer

    LWH-0400 Linear Position Transducer

    Transducer Type Resistive Country of Origin Made in India Resistance Value 5k Ohm Tolerance (+-) 5% Frequency 50 Hz Availability In Stock

    Rs. 12,000.00

  • LY4N DC24

    LY4N DC24

    Ratings Operating indicator LED Degree of protection Closed type (cover) Terminal structure Plug-in terminal Coil Coil ratings 24 VDC 69 mA Coil resistance 350 Ω Operate voltage (Set voltage) 80 % max. Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 1.5 W Contact Contact rated load 10 A (Resistive load)110 VAC 7.5 A (Inductive load (cosφ = 0.4))24 VDC 10 A (Resistive load)24 VDC 5 A (Inductive load (L/R = 7 ms)) Max. contact voltage 250 VAC125 VDC Max. contact current AC: 10 ADC: 10 A Contact form 4PDT Contact method Single Contact material Ag alloy Performance Contact resistance 50 mΩ max. (Voltage drop method with 5 VDC 1 A) Operating time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) Reset time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) Maximum operating frequency Mechanical: 18000 time/hourRated load: 1800 time/hour Insulation resistance Between coil and contacts: 100 MΩ min. (at 500 VDC)Between contacts of same polarity: 100 MΩ min. (at 500 VDC)Between contacts of different polarity: 100 MΩ min. (at 500 VDC) Dielectric strength Between coil and contacts: 2000 VAC 50/60 Hz 1 minBetween contacts of same polarity: 1000 VAC 50/60 Hz 1 minBetween contacts of different polarity: 2000 VAC 50/60 Hz 1 min Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude) Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude) Shock resistance (destruction) 1000 m/s2 Shock resistance (Malfunction) 200 m/s2 Endurance (Mechanical) 100 million operations min. (switching frequency 18,000 operations/h) Failure rate 100 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute) Ambient temperature (Operating) -25 to 40 ℃ (with no freezing or condensation) Ambient humidity (Operating) 5 to 85 % Weight Approx. 70 g Mounting method Socket Applicable socket PTF-14-PU-L/ PTF14A/ PTFZ-14-E/ PT14/ PT14QN/ PT14-0

    Rs. 650.00

  • Lzj-10 Flowmeter

    Lzj-10 Flowmeter

    Model NO. LZJ-10 Accuracy >±1% Main Application Water, Wastewater, Nature Gas Size < DN5 Sensor Tube/Flange Application Industrial Production Type Variable Area Flow Meter Measuring Media Liquid Measuring Principle Mechanics Measurement Object Closed Pipeline Certification ISO Measuring Range: Water(20 Celsius) 16 ~ 400ml/Min Measuring Range:Air (20 C, 101325PA) 0.3 ~ 7L/Min Range Scale 10:1 Operating Temperature -20 ~ +120 Celsius Operating Pressure 0 ~ 0.2 MPa Trademark Shuang huan Transport Package Carton or Plywood Specification 10*20*20cm Origin China Jiangsu Changzhou HS Code 9026900000 Product Description 2019 latest flowmeter LZB/LZJ series Technology:Model: LZB-4WBFSize: DN4Measuring range: Water (20 º C) 16 ~ 400ml/minAir (20 º C 101325Pa) 0.3 ~ 7L/minRange scale: 10: 1Accuracy: 4Operating pressure: 0 ~ 0.2 MPaOperating temperature: -20 ~ +120º CConnection: Hose, screw

    Rs. 5,200.00

  • M0DEL- HMI-GOT-GS2107-WTBD-NMITSUBISHI

    M0DEL- HMI-GOT-GS2107-WTBD-NMITSUBISHI

    FA-HMI: Human Machine Interface Series GOT SIMPLE SERIES Type GS21 MODEL Display TFT Display Colour 65536 Display Size (Inch) 7 Resolution (Pixels) 800X480 Power Supply (V) 24 Current Type DC Protection Class IP65F Internal Memory Capacity (MB) 15 Memory Card Slot SD USB 1 Ethernet Port 1 RS-232 1 RS-422/485 1 Network Options MODBUS, CCLINK, ETHERNET Conformity CE COMPLIANT UL/cUL COMPLIANT EAC NON-COMPLIANT Shipping Approvals NON-COMPLIANT UKCA COMPLIANT Product Dimensions & Weight Width (mm) 206 Height (mm) 155 Depth (mm) 50 Weight (kg) 0,71

    Rs. 16,628.56

  • M10 HEX NUT

    M10 HEX NUT

    Material Stainless Steel Fastener Type Hex Thread Size M2 Exterior Finish Stainless Steel Metal Type Stainless Steel Brand Generic Item dimensions L x W x H 25 x 25 x 25 Millimeters Item Weight 100 Grams Thread Style Right Hand Thread Coverage Fully Threaded See less About this item Material: Made from high-quality stainless steel grade SS304, offering excellent corrosion resistance. Standard: Complies with DIN 934 specifications for hexagonal nuts, ensuring compatibility with standard M2 threaded fasteners. Size: Designed for M2 thread size (2mm), suitable for precise and secure fastening applications. Durability: Highly durable and resistant to wear, suitable for use in demanding environments, including marine and outdoor settings. Applications: Commonly used in construction, automotive, marine, and general engineering industries.

    Rs. 4.13

© 2026 Industry Baba, Powered by Shopify

      Login

      Forgot your password?

      Don't have an account yet?
      Create account