Automation Products
-
MODEL-AC DRIVE 7.5KW 3 PHASE 415 VAC MAKE SCHNEIDER
Brand Others Input Phase 3 - Phase Input Voltage 500 V Input Frequency 60 Hz Motor Power 7.5 Kw Model Name/Number ATV320U75N4C Brand Schneider
Rs. 31,624.00
-
MODEL-(LIGHT EMITTING DIODE)
Brand Electronic Spices Light Type LED Special Feature Dimmable Wattage 2 Watts Bulb Shape Size A15 Bulb Base B22D Specific Uses For Product General Purpose Light Colour White Voltage 1.8 Volts Net Quantity 20 Count
Rs. 35.40
-
MODEL-ARDUINO UNO R3 COMPATIBE TYPE
Brand Robocraze Model Name UNO R3 RAM Memory Installed Size 2 KB Memory Storage Capacity 32 KB CPU Model 68EZ328 About this item The UNO R3 board compatible with Arduino has micro controllers: ATmega328 This UNO board compatible with arduino has 14 digital input/output pins (of which 6 can be used as PWM outputs) 6 analog inputs, a 16 MHz crystal oscillator, a USB connection, a power jack, an ICSP header, and a reset button Input Voltage (Recommended): 7V ~ 12V The package includes: 1x UNO R3 board compatible with Arduino and 1x USB cable
Rs. 241.90
-
MODEL-0811404821-4WRPEH 10 C1 B100L-2X/G24K0/A
Item specifics Condition New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is ... Read moreabout the condition Type Hydraulic MPN 0811404821 Brand Rexroth Valve Type Proportional Directional Model 4WRPEH 10 C1 B100L-2X/G24K0/A1M
Rs. 432,471.18
-
MODEL-DRILL PRESS;280RPM, 31MM WITH MAGNETIC STAND-DRILL MACHINE MAGNETIC 31MM HEAVY DUTY 850, WITH MAGNETIC STAND (NA)
Model Name/Number NW10 Brand Ralliwolf No Load Speed 280rpm Warranty 1 year Twist Drill Capacity 31mm Max. Drill Diameter 31mm Availability In Stock Highest torque load capacity 31mm heavy duty drill bench drill stand type ES3 Can be operated on magnetic stand Best output on a magnetic stand Al-die cast body
Rs. 43,070.00
-
MODEL-BATTERY CHARGER 12V, 15A FULLY AUTOMATIC DIGITRONIX
Brand DigiTronix Colour White Product Dimensions 9.5D x 15.5W x 8.5H Centimeters Item Weight 800 Grams Output Voltage 12 Volts About this item SMPS Based Battery Charger For Car Bike Truck Bus DG Set & Tractor Batteries Charging Method FCBC Suitable for Batteries up to 150Ah Suitable for Inverter Batteries
Rs. 3,068.00
-
MODEL-SS WELDING ROD
World Class Welding Electrodes Material : Super Stainless 308L Size : 3.15 x 350mm Weight : 2Kg
Rs. 767.00
-
Rs. 306.80
-
MODEL- DIGITAL MULTIMETER-DT4282 WITH DATA SHEET CALIBRATI ON CERTIFICATE & TRACEBIL ITY
Basic specifications Accuracy guaranteed: 1 yearRegarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. DC Voltage range 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. AC Voltage(*1) range 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) DC + AC Voltage(*1) range 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)Basic accuracy: ±0.03 % rdg. ±2 dgt. DC Current range 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. AC Current(*1) range 600.00 μA to 10.000 A, 6 ranges,Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) AC Current(*1) range(use with Clamp on probes) N/A Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)AC V, DC/AC A measurement:Signal width 1 msec or more (single), 250 μsec or more (repeated) Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages Frequency range AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stagesDisplay dB conversion value of AC voltage (dBV) Temperature(thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C Other functions Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion Display Main and Sub displays: 5-digits LCD, max. 60000 digits Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) Power supply LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) Included accessories Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 (*1)Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed. (*2)Replaced by the probe L9300 starting with batches manufactured in March, 2025.
Rs. 31,270.00
-
MODEL- DIGITAL MULTIMETER-DT4282 WITH DATA SHEET CALIBRATI ON CERTIFICATE & TRACEBIL ITY
Basic specifications Accuracy guaranteed: 1 yearRegarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. DC Voltage range 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. AC Voltage(*1) range 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) DC + AC Voltage(*1) range 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)Basic accuracy: ±0.03 % rdg. ±2 dgt. DC Current range 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. AC Current(*1) range 600.00 μA to 10.000 A, 6 ranges,Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) AC Current(*1) range(use with Clamp on probes) N/A Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)AC V, DC/AC A measurement:Signal width 1 msec or more (single), 250 μsec or more (repeated) Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages Frequency range AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stagesDisplay dB conversion value of AC voltage (dBV) Temperature(thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C Other functions Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion Display Main and Sub displays: 5-digits LCD, max. 60000 digits Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) Power supply LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) Included accessories Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 (*1)Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed. (*2)Replaced by the probe L9300 starting with batches manufactured in March, 2025.
Rs. 31,270.00
-
MODEL- DIGITAL MULTIMETER-DT4282 WITH DATA SHEET CALIBRATI ON CERTIFICATE & TRACEBIL ITY
Basic specifications Accuracy guaranteed: 1 yearRegarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. DC Voltage range 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. AC Voltage(*1) range 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) DC + AC Voltage(*1) range 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)Basic accuracy: ±0.03 % rdg. ±2 dgt. DC Current range 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. AC Current(*1) range 600.00 μA to 10.000 A, 6 ranges,Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) AC Current(*1) range(use with Clamp on probes) N/A Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)AC V, DC/AC A measurement:Signal width 1 msec or more (single), 250 μsec or more (repeated) Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages Frequency range AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stagesDisplay dB conversion value of AC voltage (dBV) Temperature(thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C Other functions Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion Display Main and Sub displays: 5-digits LCD, max. 60000 digits Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) Power supply LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) Included accessories Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 (*1)Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed. (*2)Replaced by the probe L9300 starting with batches manufactured in March, 2025.
Rs. 31,270.00
-
MODEL- DIGITAL MULTIMETER-DT4282 WITH DATA SHEET CALIBRATI ON CERTIFICATE & TRACEBIL ITY
Basic specifications Accuracy guaranteed: 1 yearRegarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. DC Voltage range 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. AC Voltage(*1) range 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) DC + AC Voltage(*1) range 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)Basic accuracy: ±0.03 % rdg. ±2 dgt. DC Current range 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. AC Current(*1) range 600.00 μA to 10.000 A, 6 ranges,Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) AC Current(*1) range(use with Clamp on probes) N/A Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)AC V, DC/AC A measurement:Signal width 1 msec or more (single), 250 μsec or more (repeated) Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages Frequency range AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stagesDisplay dB conversion value of AC voltage (dBV) Temperature(thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C Other functions Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion Display Main and Sub displays: 5-digits LCD, max. 60000 digits Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) Power supply LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) Included accessories Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 (*1)Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed. (*2)Replaced by the probe L9300 starting with batches manufactured in March, 2025.
Rs. 31,270.00