Electronic Components
-
MODEL-MITSUBISHI ELECTRIC PART NO-FX5-8EX/ES
FA-COM PLC: Digital I/O Module Series MELSEC IQ-F SERIES Type DC INPUT (SINK/SOURCE) Power Supply (V) 24 Current Type DC Occupied I/O Points on PLC 8 Integrated Digital Inputs 8 Conformity CE COMPLIANT UL/cUL COMPLIANT EAC NON-COMPLIANT Shipping Approvals ABS,BV,DNV GL,KR,LR,NK,RINA UKCA COMPLIANT Product Dimensions & Weight Width (mm) 40 Height (mm) 90 Depth (mm) 83 Weight (kg) 0,159
Rs. 4,224.40
-
MODEL-COIL FOR BURNER PUMP
Product Overview Key Features DC coil with electronic control for pump designed by us have a diverse application area and are offered at reasonable prices. They are fabricated from high grade raw material and are used in defense, hydraulic, pneumatic, submersible pumps, automotive and other such industries.
Rs. 1,180.00
-
MODEL-PUMP WITH COIL ASSEMBLY MODEL-NO AS 47 A(PV) MAKE SUNTEC
Brand Suntec Model AS 47A Max Flow Rate 47 l/h Voltage AC 230V Filter Area Inbuilt Application Oil Pump Availability In Stock Visit Online Purchase Website https://www.burnerbox.in/product/suntec-oil-pump-as47a/ We are Exclusive Resellers for Suntec Oil Pump, Solenoid Coils, Pump Couplings and Solenoid Coil Cables Suntec Products Includes Suntec Burner Pumps Suntec Pump AS47A Suntec Pump AS47C Suntec Pump D57A Suntec Pump D57C Suntec Pump E4NC 1069 Suntec Pump E4NA 1069 Suntec Pump AJ 6CC Suntec Pump AT2 47C Suntec Pump AL 65C Suntec Pump AL 65B Suntec Pump AS 67 C Suntec Pump AS 67 A Suntec Pump AN 77 A Suntec Pump AE 67 C Suntec Pump AE 97 E Suntec Pump AL 65 C Suntec Pump AL 95 C Suntec Pump J 6 CC Suntec Pump. E 6 NA Suntec Pump E 6 NC Suntec 2 Stage Pumps Suntec Pump AT2 45A Suntec Pump AT2 45C Suntec Pump AT3 45A Suntec Pump AT3 45C Suntec Pump Spare Parts Suntec Pump Coupling Suntec Pump Solenoid Coil Suntec Pump Coil Plug Suntec Pump Coil Cable Suntec Products includes Oil Pumps, Pump Solenoid Coils, AS47A Pump, AS47C Pump, D57A Pump, D57C Pump, E4NC Pump, E4NA Pump, AJ6CC Pump, AL65C Pump, AT24C Pump and more We Supply Suntec Products in all the states of India, Andhra Pradesh, Arunachal Pradesh, Assam, Bihar, Chhattisgarh, Goa, Gujarat, Haryana, Chandigarh, Himachal Pradesh, Jammu and Kashmir, Srinagar and Jammu, Jharkhand, Karnataka, Kerala, Madhya Pradesh, Maharashtra, Manipur, Meghalaya, Mizoram, Nagaland, Orissa, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Uttaranchal, Uttar Pradesh, West Bengal, Andaman and Nicobar Islands, Port Blair, Chandigarh, Dadar and Nagar Haveli, Silvassa, Daman and Diu Daman, Delhi, Lakshadweep, Pondicherry We also Supply in following major cities in India, Delhi, Mumbai, Kolkata, Bangalore, Bengaluru, Mysore, Mysuru, Pune, Hyderabad, Chennai, Ahmedabad, Visakhapatnam, Surat, Kanpur, Lucknow, Hyderabad, Amaravati, Itanagar, Dispur, Patna, Raipur, Panaji, Gandhinagar, Shimla, Ranchi, Thiruvananthapuram, Bhopal, Imphal, Shillong, Aizawi, Kohima, Bhubaneshwar, Chandigarh, Jaipur, Gangtok, Agartala, Dehradun, Kavaratti
Rs. 2,515.17
-
MODEL-(PLC CPU-FX3U-64MR/ES-64 I/O-32 I/P-DIGITAL INPUT-32 O/P) MAKE MITSUBISHI
FA-COM PLC: Main Unit Type FX3U Power Supply (V) 100-240 Current Type AC Program Memory 64K STEPS Program Memory Unit RAM Integrated Digital Inputs 32 Integrated Digital Outputs 32 Output Type RELAY Local I/O Points 256 Local + Remote I/O Points 384 Expandable YES Cycle Time LD (ns) 65 Cycle Time MOV (ns) 642 USB OPTION RS-422 1 Power Consumption (W) 45 Buffer Battery YES Protection Class IP10 Min. Ambient Temperature (°C) 0 Max. Ambient Temperature (°C) 55 Series MELSEC-F SERIES Conformity CE COMPLIANT UL/cUL COMPLIANT EAC NON-COMPLIANT Shipping Approvals ABS,BV,DNV GL,KR,LR,NK,RINA UKCA COMPLIANT Product Dimensions & Weight Width (mm) 220 Height (mm) 90 Depth (mm) 86 Weight (kg) 1
Rs. 31,000.00
-
MODEL- BATTERY BR-2/3AGCT4A6V MAKE PANASONIC
Number of Batteries 1 Nonstandard Battery batteries required. Brand Lipix Net Quantity 1.0 Count Voltage 6 Volts Reusability Single Use Model Name Br2/3agct4a Item dimensions L x W x H 34 x 17 x 15 Millimeters Item Weight 70 Grams Amperage 4400 Special Feature 2-pin Wire Connector
Rs. 530.00
-
MODEL-AC DRIVE 7.5KW 3 PHASE 415 VAC MAKE SCHNEIDER
Brand Others Input Phase 3 - Phase Input Voltage 500 V Input Frequency 60 Hz Motor Power 7.5 Kw Model Name/Number ATV320U75N4C Brand Schneider
Rs. 31,624.00
-
MODEL-ARDUINO UNO R3 COMPATIBE TYPE
Brand Robocraze Model Name UNO R3 RAM Memory Installed Size 2 KB Memory Storage Capacity 32 KB CPU Model 68EZ328 About this item The UNO R3 board compatible with Arduino has micro controllers: ATmega328 This UNO board compatible with arduino has 14 digital input/output pins (of which 6 can be used as PWM outputs) 6 analog inputs, a 16 MHz crystal oscillator, a USB connection, a power jack, an ICSP header, and a reset button Input Voltage (Recommended): 7V ~ 12V The package includes: 1x UNO R3 board compatible with Arduino and 1x USB cable
Rs. 241.90
-
MODEL-BATTERY CHARGER 12V, 15A FULLY AUTOMATIC DIGITRONIX
Brand DigiTronix Colour White Product Dimensions 9.5D x 15.5W x 8.5H Centimeters Item Weight 800 Grams Output Voltage 12 Volts About this item SMPS Based Battery Charger For Car Bike Truck Bus DG Set & Tractor Batteries Charging Method FCBC Suitable for Batteries up to 150Ah Suitable for Inverter Batteries
Rs. 3,068.00
-
MODEL-SS WELDING ROD
World Class Welding Electrodes Material : Super Stainless 308L Size : 3.15 x 350mm Weight : 2Kg
Rs. 767.00
-
MODEL- DIGITAL MULTIMETER-DT4282 WITH DATA SHEET CALIBRATI ON CERTIFICATE & TRACEBIL ITY
Basic specifications Accuracy guaranteed: 1 yearRegarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. DC Voltage range 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. AC Voltage(*1) range 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) DC + AC Voltage(*1) range 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)Basic accuracy: ±0.03 % rdg. ±2 dgt. DC Current range 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. AC Current(*1) range 600.00 μA to 10.000 A, 6 ranges,Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) AC Current(*1) range(use with Clamp on probes) N/A Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)AC V, DC/AC A measurement:Signal width 1 msec or more (single), 250 μsec or more (repeated) Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages Frequency range AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stagesDisplay dB conversion value of AC voltage (dBV) Temperature(thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C Other functions Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion Display Main and Sub displays: 5-digits LCD, max. 60000 digits Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) Power supply LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) Included accessories Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 (*1)Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed. (*2)Replaced by the probe L9300 starting with batches manufactured in March, 2025.
Rs. 31,270.00
-
MODEL- DIGITAL MULTIMETER-DT4282 WITH DATA SHEET CALIBRATI ON CERTIFICATE & TRACEBIL ITY
Basic specifications Accuracy guaranteed: 1 yearRegarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. DC Voltage range 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. AC Voltage(*1) range 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) DC + AC Voltage(*1) range 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)Basic accuracy: ±0.03 % rdg. ±2 dgt. DC Current range 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. AC Current(*1) range 600.00 μA to 10.000 A, 6 ranges,Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) AC Current(*1) range(use with Clamp on probes) N/A Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)AC V, DC/AC A measurement:Signal width 1 msec or more (single), 250 μsec or more (repeated) Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages Frequency range AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stagesDisplay dB conversion value of AC voltage (dBV) Temperature(thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C Other functions Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion Display Main and Sub displays: 5-digits LCD, max. 60000 digits Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) Power supply LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) Included accessories Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 (*1)Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed. (*2)Replaced by the probe L9300 starting with batches manufactured in March, 2025.
Rs. 31,270.00
-
MODEL- DIGITAL MULTIMETER-DT4282 WITH DATA SHEET CALIBRATI ON CERTIFICATE & TRACEBIL ITY
Basic specifications Accuracy guaranteed: 1 yearRegarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information. DC Voltage range 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. AC Voltage(*1) range 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) DC + AC Voltage(*1) range 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHzBasic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) Resistance range 60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)Basic accuracy: ±0.03 % rdg. ±2 dgt. DC Current range 600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt. AC Current(*1) range 600.00 μA to 10.000 A, 6 ranges,Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range) AC Current(*1) range(use with Clamp on probes) N/A Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)AC V, DC/AC A measurement:Signal width 1 msec or more (single), 250 μsec or more (repeated) Capacitance range 1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt. Continuity Check Continuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more Diode test Open terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages Frequency range AC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt. dB conversion Standard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stagesDisplay dB conversion value of AC voltage (dBV) Temperature(thermocouples) K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C Other functions Filter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion Display Main and Sub displays: 5-digits LCD, max. 60000 digits Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s ) Power supply LR6 (AA) alkaline batteries ×4, Continuous use: 100 hours Dimensions and mass 93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries) Included accessories Test Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4 (*1)Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed. (*2)Replaced by the probe L9300 starting with batches manufactured in March, 2025.
Rs. 31,270.00