{"product_id":"150-c9nbr-allen-bradley","title":"150-C9NBR allen bradley","description":"\u003ctable class=\"ra-product-new__product-table-section\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eWith display\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eFalse\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eVoltage type for actuating\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eAC\/DC\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRated operating voltage Ue\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e200 V\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRated control supply voltage at AC 50 Hz\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e24 V\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRated control supply voltage at AC 60 Hz\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e24 V\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eOverload current\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e3 A\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eController type\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eSMC-3\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eDV\/DT protection\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e1000V\/µs for power circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRepetitive peak voltage\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e1400V per UL\/CSA\/NEMA for power circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eOperating frequency\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e50\/60 Hz per UL\/CSA\/NEMA for power circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eLine connected motor power, max\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e4 kW @ 380\/400\/415V AC @ 50Hz, 3-phase\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eDelta connected motor power, max\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e2.2...7.5 kW @ 380\/400\/415V AC @ 50Hz, 3-phase\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eIII per IEC for side mount auxiliary contacts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRated impulse voltage\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e6 kV for power circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eDielectric withstand\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e2500V AC per IEC for power circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eLine connected motor current\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e3...9A @ 380\/400\/415\/460V AC, 3-phase\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eDelta connected motor current\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e5.1...16A @ 380\/400\/415\/460V AC, 3-phase\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eInsulation voltage\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eRated 600V AC per UL\/CSA\/NEMA for power circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRated operational voltage\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e250V AC\/30V DC per UL\/CSA\/NEMA for Side mount auxiliary contacts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRated control power during start with fan\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e215mA @ 120V AC\/180mA @ 240V AC, 800mA @ 24V DC\/660mA @ 24V AC\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eInput OFF-state current\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e\u0026lt;10 mA, \u0026lt;12 mA @ input OFF-state voltage (IN1, IN2) for control circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eShort-circuit protection device list\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eNon-time delay Thermal magnetic circuit breaker High capacity time delay class CC\/J\/L\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eNumber of contacts\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eTB-97, -98 (OVLD\/Fault): 1 for auxiliary contacts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eHigh capacity available fault current, max\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e69kA @ 600V, maximum current 30 A time delay Class J or Class L fuse for inside delta connected motors\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eType of current\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eTB-97, -98 (OVLD\/Fault): AC\/DC for auxiliary contacts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eConventional thermal current (Ith)\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eTB-97, -98 (OVLD\/Fault): 1 A for auxiliary contacts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eType of control circuit\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eTB-97, -98 (OVLD\/Fault): Electromagnetic relay for auxiliary contacts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eType of contacts\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eTB-97, -98 (OVLD\/Fault): Normally Open (N.O.) for auxiliary contacts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eUtilization category\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eTB-23, -24 (normal\/up-to-speed), TB-33, -34 (normal\/up-to-speed): C300\/R150 per UL\/CSA\/NEMA for Side mount auxiliary contacts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRated operational current, max\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eTB-97, -98 (OVLD\/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eStandard controller feature\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eSoft stop\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eStandard available fault current, max\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e5 kA @ maximum standard fuse 60 A for delta device opsal current rating\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRated control supply voltage at DC\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e24 V\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eIntegrated motor overload protection\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eTrue\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eShort circuit protection device performance (SCPD) type\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eType 1\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eSelectable overload trip class\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003eTrip Class 10, 15, or 20\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eSelectable start times\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e2, 5, 10, 15, 20, 25, or 30 s\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eInput OFF-state voltage (IN1, IN2), max\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e40V AC @ 17V DC\/12V AC for control circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eSelectable current limit\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e150%, 250%, 350%, and 450% of full load current\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eInput ON-state voltage, during start (IN1, IN2)\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e85V AC @ 19.2V DC\/19.2V AC minimum for control circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eRated control power during start without fan\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e205mA @ 120V AC\/145mA @ 240V AC, 705mA @ 24V DC\/580mA @ 24V AC\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"ra-product-new__product-table-cell\"\u003eInput ON-state current (IN1, IN2)\u003c\/th\u003e\n\u003ctd class=\"ra-product-new__product-table-cell\"\u003e\n\u003cdiv class=\"ra-product-new__product-table-cell-content\"\u003e9.8mA @ 120V AC\/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC\/DC for control circuit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Industry Baba","offers":[{"title":"Default Title","offer_id":43757730332769,"sku":null,"price":21646.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0569\/0186\/1473\/files\/150-C16NCD_1000x1000_117b630d-382e-4d3d-b4bc-2f2b0c5d35c6.jpg?v=1773818359","url":"https:\/\/industrybaba.com\/products\/150-c9nbr-allen-bradley","provider":"Industry Baba","version":"1.0","type":"link"}