{"product_id":"bk9103","title":"BK9103","description":"\u003cp class=\"Copy_text_without_indent\"\u003eThe BK9103 Bus Coupler connects PROFINET RT with the modular, extendable electronic terminal blocks. One unit consists of one Bus Coupler, any number from 1 to 64 terminals (255 with K-bus extension) and one end terminal.\u003c\/p\u003e\n\u003cp class=\"Copy_text\"\u003eThe Bus Couplers recognize the terminals to which they are connected, and perform the assignment of the inputs and outputs to the words of the process image automatically. The BK9103 Bus Coupler supports 10 Mbit\/s and 100 Mbit\/s\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.beckhoff.com\/en-en\/products\/i-o\/overview-fieldbus-systems\/ethernet-tcp-ip\/\" title=\"High data transmission rates and easy methods of integration\"\u003eEthernet\u003c\/a\u003e. Connection is through normal RJ45 connectors. The IP address is set on the DIP switch (offset to a freely selectable start address). In networks with DHCP (a service for the allocation of the logical IP address to the physical node address [MAC-ID]) the Bus Coupler obtains its IP address from the DHCP server.\u003c\/p\u003e\n\u003cp class=\"Copy_text\"\u003eThe BK9103 contains a 3-port switch. Two ports operate external on RJ45 connectors and can be utilized. The\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.beckhoff.com\/en-en\/products\/i-o\/#text_bild_1\" title=\"Fieldbus components for all common I\/Os\"\u003eI\/O\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003estations can thus be configured with a line topology instead of the classic star topology. In many applications this significantly reduces the wiring effort and the cabling costs. The maximum distance between two couplers is 100 m. Up to 20 BK9103 Bus Couplers are cascadable, so that a maximum line length of 2 km can be achieved.\u003c\/p\u003e\n\u003cp class=\"Copy_text\"\u003ePROFINET is the open Industrial Ethernet standard of the PNO (\u003ca href=\"https:\/\/www.beckhoff.com\/en-en\/products\/i-o\/overview-fieldbus-systems\/profibus\/#text_bild_1\" title=\"Bus for decentralized peripheral components\"\u003ePROFIBUS\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eNutzerorganisation). Internationally established IT standards such as TCP\/IP are used for communication. PROFINET RT describes the data exchange between controllers and field devices and can be used in standard Ethernet networks. Commercial switches are used for networking purposes.\u003c\/p\u003e\n\u003cdiv class=\"table-rwd\"\u003e\n\u003ctable class=\"product-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical data\u003c\/th\u003e\n\u003cth\u003eBK9103\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Bus Terminals\u003c\/td\u003e\n\u003ctd\u003e64 (255 with K-bus extension)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. number of bytes fieldbus\u003c\/td\u003e\n\u003ctd\u003e512 byte input and 512 byte output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital peripheral signals\u003c\/td\u003e\n\u003ctd\u003e512 inputs\/outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog peripheral signals\u003c\/td\u003e\n\u003ctd\u003e256 inputs\/outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003evia KS2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFINET RT (Class B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData transfer rates\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s, automatic recognition of the transmission rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus interface\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 (2-channel switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData transfer medium\u003c\/td\u003e\n\u003ctd\u003e4 x 2 twisted pair copper cable; category 3 (10 Mbit\/s), category 5 (100 Mbit\/s)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC (-15%\/+20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current\u003c\/td\u003e\n\u003ctd\u003e70 mA + (total K-bus current)\/4, 500 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting current\u003c\/td\u003e\n\u003ctd\u003e2.5 x continuous current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended fuse\u003c\/td\u003e\n\u003ctd\u003e≤ 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent supply K-bus\u003c\/td\u003e\n\u003ctd\u003e1750 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower contacts\u003c\/td\u003e\n\u003ctd\u003emax. 24 V DC\/max. 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical isolation\u003c\/td\u003e\n\u003ctd\u003e500 V (power contact\/supply voltage\/fieldbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eline or star wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance between stations\u003c\/td\u003e\n\u003ctd\u003e100 m between hub\/switch and bus coupler or between bus coupler and bus coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 170 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-25…+60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40…+85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e95%, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\/shock resistance\u003c\/td\u003e\n\u003ctd\u003econforms to EN 60068-2-6\/EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC immunity\/emission\u003c\/td\u003e\n\u003ctd\u003econforms to EN 61000-6-2\/EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtect. rating\/installation pos.\u003c\/td\u003e\n\u003ctd\u003eIP20\/variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\/markings\u003c\/td\u003e\n\u003ctd\u003eCE, CCC, UL, ATEX, IECEx, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEx marking\u003c\/td\u003e\n\u003ctd\u003eATEX: II 3 G Ex ec IIC T4 Gc\u003cbr\u003eIECEx: Ex ec IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-anchors\"\u003e\n\u003ca id=\"tab_content_anchor_0_2\" class=\"smooth-scroll-target\" name=\"tab_content_anchor_0_2\"\u003e\u003c\/a\u003e\n\u003cdiv class=\"desktop\"\u003e\n\u003cdiv class=\"tab-anchors__grid\"\u003e\n\u003cdiv class=\"tab-anchors__left\"\u003e\n\u003cul class=\"nav nav-pills\"\u003e\n\u003cli class=\"nav-item\"\u003e\u003cbutton class=\"nav-link smooth-scroll\" type=\"button\" data-target=\"#tab_content_anchor_0_0\"\u003eTechnical data\u003c\/button\u003e\u003c\/li\u003e\n\u003cli class=\"nav-item\"\u003e\u003cbutton class=\"nav-link smooth-scroll active\" type=\"button\" data-target=\"#tab_content_anchor_0_2\"\u003eHousing data\u003c\/button\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Industry Baba","offers":[{"title":"Default Title","offer_id":43773265313889,"sku":null,"price":42151.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0569\/0186\/1473\/files\/bk9103__web_preview_png.webp?v=1774422046","url":"https:\/\/industrybaba.com\/products\/bk9103","provider":"Industry Baba","version":"1.0","type":"link"}