Function |
Total Counter |
Counter |
Count range |
0 to 99999999 |
Max. counting speed |
30 Hz/1 kHz (switching) (ON/OFF ratio 1:1) |
Minimum input signal width |
30 Hz: 16.7 ms 1 kHz: 0.5 ms |
Input mode |
Increment (UP) |
Reset system |
External and manual reset |
Input |
Input signal |
Count input, Reset |
Input method |
No-voltage input |
No-voltage input (No-contact input) |
Short-circuit (ON) impedance: 10 kΩ max. Residual voltage: 0.5 V max. (Actual performance 1.0 V) Open circuit impedance: 750 kΩ min. |
Reset time |
External reset |
20 ms |
Manual reset |
20 ms |
Display |
Display method |
LCD |
Digits |
8 digit |
Character height |
8.6 mm (Black) |
Zero suppression |
Equipped |
Key protection |
Key protect Switch |
Ambient temperature (Operating) |
-10 to 55 ℃ (with no freezing or condensation) |
Ambient temperature (Storage) |
-25 to 65 ℃ (with no freezing or condensation) |
Ambient humidity (Operating) |
25 to 85 % |
Insulation resistance |
Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) |
Dielectric withstand voltage |
Between current carrying terminals and exposed non-current carrying metal parts: 1000 VAC 50/60 Hz 1 min |
Impulse withstand voltage |
Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV |
Noise immunity |
Between count input terminals: ±500 V Between reset terminals: ±500 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
Static immunity |
±8 kV (malfunction) |
Vibration resistance |
Destruction: 10 to 55 Hz, 0.375 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.15 mm single amplitude each in 3 directions for 10 min |
Shock resistance |
Destruction: 300 m/s2, 3 times each in 6 directions Malfunction: 200 m/s2, 3 times each in 6 directions |
Degree of protection |
Case front: IP66, NEMA 4 (indoors), and UL Type 4X (indoors) |
External connection method |
Screw terminal |
Case color |
Light gray (Munsell 5Y7/1) |
Weight |
Approx. 60g |