Function |
Time Counter |
Time counter |
Time ranges |
Increment (UP) |
Time ranges |
0.0 h to 999999.9 h/0.0 h to 3999 d 23.9 h (selectable) |
Set value read selector |
±100 ppm (25 ℃) |
Minimum signal input width |
1 s |
Reset system |
External and manual reset |
Input |
Input signal |
Count input, Reset |
Input method |
Voltage input |
Voltage input |
Hight level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance Approx. 4.7 kΩ) |
Reset time |
External reset |
20 ms |
Manual reset |
20 ms |
Display |
Display method |
LCD |
Digits |
7 digit |
Character height |
8.6 mm (Black) |
Zero suppression |
Equipped |
Key protection |
Key protect Switch |
Ambient temperature (Operating) |
-10 to 55 ℃ (with no freezing or condensation) |
Ambient temperature (Storage) |
-25 to 65 ℃ (with no freezing or condensation) |
Ambient humidity (Operating) |
25 to 85 % |
Insulation resistance |
Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) |
Dielectric withstand voltage |
Between current carrying terminals and exposed non-current carrying metal parts: 1000 VAC 50/60 Hz 1 min |
Impulse withstand voltage |
Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV |
Noise immunity |
Between reset terminals: ±600 V Between timer input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
Static immunity |
±8 kV (malfunction) |
Vibration resistance |
Destruction: 10 to 55 Hz, 0.375 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.15 mm single amplitude each in 3 directions for 10 min |
Shock resistance |
Destruction: 300 m/s2, 3 times each in 6 directions Malfunction: 200 m/s2, 3 times each in 6 directions |
Degree of protection |
Case front: IP66, NEMA 4 (indoors), and UL Type 4X (indoors) |
External connection method |
Screw terminal |
Case color |
Light gray (Munsell 5Y7/1) |
Weight |
Approx. 60 g |