Model
|
GT-76A
|
|
Type
|
Amplifier unit
|
|
Mounting type
|
Panel mount
|
|
Output
|
NPN output
|
|
Main unit/Expansion unit
|
Expansion unit*1
|
|
Power consumption
|
Normal
|
At 12 V: 1,140 mW (95 mA) or less, At 24 V: 1,200 mW (50 mA) or less
|
|
Power saving (Eco)
|
At 12 V: 600 mW (50 mA) or less, At 24 V: 840 mW (35 mA) or less
|
|
Display power
|
Measured value display
|
6-digit 7-segment LED (red)
|
|
Other displays
|
2-colour 13-level bar LED display (red, green), indicators (red, green)
|
|
Display range
|
-99.999 to 999.999
|
|
Display resolution
|
1 µm
|
|
Sampling rate
|
2,000 times/second
|
|
Control input
|
Timing/preset/bank input
|
Timing input: Non-voltage input (relay contact, solid state), input time: 2 ms or more Preset/Bank input: Non-voltage input (relay contact, solid state), input time: 20 ms or more
|
|
Response time
|
hsp (1.5 ms) , 5 ms, 10 ms, 100 ms, 500 ms, 1 s, 5 s
|
|
HIGH, GO, LOW output
|
NPN Offenkollektor, max. 50 mA (40 V oder weniger), Restspannung: 1 V oder weniger, N.O./N.C. umschaltbar
|
|
Major functions
|
Preset, Hold, Variable hysteresis, Variable response time, Multiplier setting, Bank function (4 banks), Self-timing, Power save (eco) mode, Application mode, Calibration function, Core alarm
|
|
Rating
|
Power voltage
|
12 to 24 VDC, Ripple (P-P) 10 % or less*2
|
|
Environmental resistance
|
Ambient temperature
|
-10 to +55 °C (No freezing)
|
|
Relative humidity
|
35 to 85 % RH (No condensation)
|
|
Vibration resistance
|
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
|
|
Material
|
Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: Polycarbonate, Cable: PVC
|
|
Accessories
|
Panel mounting bracket, protective front cover, power cable, flat cable for expansion, instruction manual
|
|
Weight
|
Approx. 110 g (: including panel mounting bracket, protective front cover, power cable)
|