| Principle |
Shear |
| Voltage sensitivity (80 Hz) ※1
|
1 mV / (m/s2) ±15 % (23 °C) |
| Vibration frequency range Hz ※2 |
1 Hz to 20 kHz (±10 %) from -50 °C to +150 °C |
| 1 Hz to 2 Hz (±15 %) from 150 °C to +170 °C |
| 2 Hz to 20 kHz (±10 %) from 150 °C to +170 °C |
| Mounting resonance frequency kHz※2 |
approx. 55 kHz |
| Maximum measurable acceleration m/s2 (peak) ※3 |
5 000 m/s2 (Peak) |
| Transverse sensitivity |
5 % or less (30 Hz) |
| Base distortion sensitivity (m/s2) / μ strain |
0.006 (m/s2) / μ strain (TYP.) (When using 3 Hz high-pass filter) |
| Thermal transient response (m/s2) / °C |
0.04 (m/s2) / °C (TYP.) (When using 3 Hz high-pass filter) |
| Standard mounting method ※4
|
M3 screw 0.5 N・m |
| Case material |
Titanium |
| Ambient temperature range for operation / °C |
-50 °C to +170 °C |
| Power supply (CCLD) |
DC18 V to 30 V (2 mA to 4 mA), rated voltage 24 V |
| Dimensions |
7 mm (Hex) × 12.5 mm (H) |
| Mass |
approx. 1.8 g |
| Supplied accessories |
Ultra-compact accelerometer cable (with ferrite core) VP-51LC (2 m) x 1, M3 screw VP-53K x 2, Insulation attachment VP-53W x 1, Single-head spanner (7 mm) x 1, Hex wrench x 1 |