{"product_id":"model-controller-csd-903b-07","title":"MODEL- CONTROLLER (CSD-903B-07)","description":"\u003ctable class=\"m-table__front is-wider\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003cth class=\"m-table__cell m-table__cell--center\"\u003e\n\u003cp class=\"m-table__title\"\u003eSpecification name\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"m-table__cell m-table__cell--center\"\u003e\n\u003cp class=\"m-table__title\"\u003eSpecification contents\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eBridge power supply\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e10 VDC±0.5VDC within 180 mA with remote sensing function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eInput sensitivity\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e0.2 μV\/d or more (d = minimum scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eInput range\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e-3.1 mV\/V to 3.1 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eZero adjustment range\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e-2.5 mV\/V to 2.5 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eNon-linearity\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e0.01 %F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eZero balance ±0.2 μV\/℃ (When the calibration is set at 0.2 μV\/d or more for input sensitivity.),Sensitivity ±0.001 5 %F.S.\/℃ (When the calibration is set at 0.2 μV\/d or more for input sensitivity.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eNoise in input signal\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e±0.2 μVP-P or less (At the default setting for analog filter, digital filter, stabilization filter and A\/D sampling.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eAnalog filter\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eSelect from 2,4,6,8,10Hz（Analog filter, digital filter, and stabilizing filter at default settings）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eA\/D sampling speed\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e200 times\/s (Changeable to 20 times\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eA\/D internal resolution\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e24 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eMain display\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eDisplay range ：-999 999 to 999 999\u003cbr\u003eDisplay incliment ：1 (changeable to 2, 5, 10, 20 or 50)\u003cbr\u003eDisplay unit ：VATN LCD (display color white, backlit) with 7 digits and 11.55 mm character height\u003cbr\u003eOver display ：'-OL' at minus over, 'OL' at plus over\u003cbr\u003eOver display of A\/D value ：'-OVF' at minus over, 'OVF' at plus over\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eSub display\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eDisplay range ：\"Total accumulation value -9 999 999 999 to 9 999 999 999,Accumulation times 0 to 999 999 \"\u003cbr\u003eDisplay unit ：VATN LCD (display color white, backlit) with 18 digits and 5 mm character height\u003cbr\u003eDisplay item ：\"changeable to no display,Issue\/Cumulative Count\/Cumulative Value (8 digits),\u003cbr\u003eIssue\/Cumulative Count\/Latest Cumulative Data, Issue \/ Latest accumulated data \/ Cumulative value (8 digits),\u003cbr\u003eIssue \/ Latest accumulated data \/ Quantitative,Issue\/accumulated count\/quantity, Issue\/quantity\/accumulated value (8 digits),\u003cbr\u003eIssue\/near zero\/full,Issue \/ Over\/Under, Issue \/ Quantitative \/ Falling, Issue \/ S1\/S2 , Issue \/ S1\/S3 ,Issue\/S1\/S4 ,\u003cbr\u003eIssue\/S2\/S3 , Issue\/S2\/S4 , Issue\/S3\/S4 , Issue\/Quantitative,Issue\/Over\/Under, Issue\/Cumulative Count,\u003cbr\u003eIssue\/Cumulative Value (10 digits), Brand \/ Latest accumulated data\u003cbr\u003e* it displays weighing value + unit during the set of function.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eStatus display\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eSTABLE, PRE.TARE, TARE, GROSS, NET, ZERO, HOLD, ERROR, Z-BAND,OK\/S0, F.FLOW\/S1, M.FLOW\/S2, D.FLOW\/S3, OVER\/S4, UNDER, FULL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eDisplay times\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e4 times\/s (Changeable to 20 times\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eDisplay of decimal point\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eChangeable to no display, 10¹, 10², 10³, 10⁴.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eDisplay of unit\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eChangeable to no display, g, kg, t, N, kN, or lb.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eExternal control input signal\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e9 signals in the following can be arbitrarily selected.\u003cbr\u003eOFF, key operation either of [ON\/OFF], [SET], [ACCUM.\/left arrow],\u003cbr\u003e[PRE-TARE\/right arrow], [TARE\/▲], [NET\/GROSS\/▼], [ZERO] or [F\/enter]. zero clear,\u003cbr\u003etare clear, flow start, DISCHARGE start, cancell former accumulation, clear accumulation,\u003cbr\u003eerror reset, print command.Manual drop compensation, completion of forced weighing,\u003cbr\u003ecompletion of forced discharge, and clearing of all stocks accumulation\u003cbr\u003e*Above is pulse input, and effective once at a pulse width of 50 ms or more.\u003cbr\u003eChange of Flow\/Weigh out (ON: Weigh-out, OFF: Flow), hold, emergency stop,Display of NET (ON: NET, OFF: GROSS),Issue No. 1,\u003cbr\u003eIssue No. 2, Issue No. 4\u003cbr\u003e* Above is level input, and effective during short input of 50 ms or more.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eExternal control output signal\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e13 signals in the following can be arbitrarily selected.\u003cbr\u003eOFF, RUN, stable, during tare, gross display, net display, zero point, during hold, capacity exceeded error,\u003cbr\u003eweighing sequece error, zero band, OK(S0), big flow (S1), medium flow (S2), Dribble flow (S3), over (S4), under,\u003cbr\u003efull, during measurement, batch finish, discharge (for gate open), discharge finish (for gate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eFunction of comparator\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eSet value -999 999 to 999 999\u003cbr\u003eNo. of set points: 4 points of S1, S2, S3 and S4\u003cbr\u003eSet value of hysteresis data width: 0 to 99 digit\u003cbr\u003eDirection of hysteresis: Selectable from 'On delay' or 'Off delay'\u003cbr\u003eConversion times of comparator: Changeable to 200 times\/s or 20 times\/s (Synchronous with the A\/D sampling rate.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003e2-wires method serial interface\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eBaud rate : 600 bps\u003cbr\u003eData bit length : 8 bit\u003cbr\u003eParity bit : Odd number\u003cbr\u003eStop bit : 1 bit\u003cbr\u003eStart bit : 1 bit\u003cbr\u003eTransmission data : Binary code, BCD\u003cbr\u003e※Photocoupler isolated from internal circuits\u003cbr\u003e※Common to external control inputs\u003cbr\u003e※Attached connector compatible plug: MC1.5\/6-ST-3.81 (manufactured by PHOENIX CONTACT)\u003cbr\u003e(Shared with RS-485 in section 2-8.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eSerial interface\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eBaud rate : Selectable from 1 200 bps, 2 400 bps, 4 800 bps, 9 600 bps, 19 200 bps or 38 400 bps.\u003cbr\u003eData bit length : Selectable from 7 bit or 8 bit.\u003cbr\u003eParity bit : Selectable from none, even or odd.\u003cbr\u003eStop bit : Selectable from 1 bit or 2 bit\u003cbr\u003eTerminator : Selectable from CR+LF or CR.\u003cbr\u003eCommunication method : Half duplex\u003cbr\u003eSynchronous method : Start-stop synchronous method\u003cbr\u003eAddress : Select one from 0 to 31.\u003cbr\u003eCommunication data : ASCII code\u003cbr\u003eCable length : Approx. 1 km\u003cbr\u003eConnectable units : Up to 32 units\u003cbr\u003e※When stream is selected in data transfer mode, one unit is connected\u003cbr\u003eTerminating resistance : Externally\u003cbr\u003eData transmission mode : Selectable from command, modbus, stream, completion signal sync, cumulative signal sync, print signal sync\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eVarious function\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e・Zero tracking\u003cbr\u003e・Stabilization filter\u003cbr\u003e・stabilizing filter\u003cbr\u003e・Calibration LOCK switch\u003cbr\u003e・Digital linearize\u003cbr\u003e・brand switching\u003cbr\u003e・Accumulating function\u003cbr\u003e・Preset tare\u003cbr\u003e・Net Amount Offset\u003cbr\u003e・net metric sign reversal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eOperating temp.\u003cbr\u003e\/humidity range\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eTemperature -10 ℃ to 50 ℃, Humidity 85 % or less (Non condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003ePower supply voltage\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e100 VAC to 240 VAC (85 VAC to 264 VAC) 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eApprox. 7 VA (without any options, at 100 VAC)\u003cbr\u003eApprox. 15 VA or less (with options, at 100 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eOutline dimensions\u003cbr\u003e(WxHxD)\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003e144 mm x 72 mm x 146.7mm (excludes protruding parts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eApprox. 1.0 kg (without options)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"m-table__line\"\u003e\n\u003ctd class=\"m-table__cell\"\u003eProtection code\u003c\/td\u003e\n\u003ctd class=\"m-table__cell\"\u003eIP65 or equivalent (Only for the fron panel when the attached panel mounting gascket is installed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Industry Baba","offers":[{"title":"Default Title","offer_id":46344666775649,"sku":null,"price":84000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0569\/0186\/1473\/files\/file_73_2.jpg?v=1785998288","url":"https:\/\/industrybaba.com\/products\/model-controller-csd-903b-07","provider":"Industry Baba","version":"1.0","type":"link"}