Model-D4C-1220-Make Omron

Description

Shape/Structure General-purpose Limit switches
ctuator Roller lever 17.5 dia. x 7
Sintered stainless steel roller
R38
Electrical ratings 5 A at 250 VAC/ 4 A at 30 VDC
Frequency 50/60 Hz
Contact form SPDT
Load General load
Ratings (AC): Non-Inductive load Resistive load: 5 A at 125 VAC/5 A at 250 VAC
Lamp load (NC): 1.5 A at 125 VAC/1 A at 250 VAC
Lamp load (NO): 7 A at 125 VAC/0.5 A at 250 VAC
Inductive load: 3 A at 125 VAC/2 A at 250 VAC
Motor load (NC): 2.5 A at 125 VAC/1.5 A at 250 VAC
Motor load (NO): 1.3 A at 125 VAC/0.8 A at 250 VAC
Ratings (DC): Non-Inductive load Resistive load: 5 A at 8 VDC/5 A at 14 VDC/4 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC
Lamp load: 2 A at 8 VDC/2 A at 14 VDC/2 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC
Inductive load (NC): 5 A at 8 VDC/4 A at 14 VDC/3 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC
Inductive load (NO): 4 A at 8 VDC/4 A at 14 VDC/3 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC
Motor load: 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC
Inrush current NC: 20 A max.
NO: 10 A max.
Earth terminal With earth wire
Cable specifications VCTF oil-resistant cable, 4 cores, 3 m
Nominal sectional area: 0.75 mm2
Diameter: 7.6 dia.
Ambient temperature Operating: -10 to 70 ℃ (with no icing)
Ambient humidity 35 to 95 %
Permissible operating frequency Electrical: 30 operations / 1 minute max.
Mechanical: 120 operations / 1 minute max.
Contact resistance (Initial value) 300 mΩ max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength Between each terminal of the same polarities: 1,000 VAC 50/60 Hz 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz 1 min
Impulse withstand voltage Between live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kV
Durability Electrical: 200,000 operations min. (5 A at 125 VAC)
Mechanical: 10 million operations min.
Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance Destruction: 1,000 m/s2 max.
Malfunction: 500 m/s2 max.
Degree of protection IP67
Classification of protection against electric shock Class I (with earth wire)
Operating Force (OF) Standard value 5.69 N max.
Release Force (RF) Standard value 1.47 N min.
Pre-Travel (PT) Standard value 25 ° max.
Movement Differential (MD) Standard value 3 ° max.
Over-Travel (OT) Standard value 40 ° mi

Model-D4C-1220-Make Omron

Product form

Shape/Structure General-purpose Limit switches ctuator Roller lever 17.5 dia. x 7Sintered stainless steel rollerR38 Electrical ratings 5 A at 250... Read more

Rs. 3,357.00 Excl. VAT

    Description

    Shape/Structure General-purpose Limit switches
    ctuator Roller lever 17.5 dia. x 7
    Sintered stainless steel roller
    R38
    Electrical ratings 5 A at 250 VAC/ 4 A at 30 VDC
    Frequency 50/60 Hz
    Contact form SPDT
    Load General load
    Ratings (AC): Non-Inductive load Resistive load: 5 A at 125 VAC/5 A at 250 VAC
    Lamp load (NC): 1.5 A at 125 VAC/1 A at 250 VAC
    Lamp load (NO): 7 A at 125 VAC/0.5 A at 250 VAC
    Inductive load: 3 A at 125 VAC/2 A at 250 VAC
    Motor load (NC): 2.5 A at 125 VAC/1.5 A at 250 VAC
    Motor load (NO): 1.3 A at 125 VAC/0.8 A at 250 VAC
    Ratings (DC): Non-Inductive load Resistive load: 5 A at 8 VDC/5 A at 14 VDC/4 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC
    Lamp load: 2 A at 8 VDC/2 A at 14 VDC/2 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC
    Inductive load (NC): 5 A at 8 VDC/4 A at 14 VDC/3 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC
    Inductive load (NO): 4 A at 8 VDC/4 A at 14 VDC/3 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDC
    Motor load: 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC
    Inrush current NC: 20 A max.
    NO: 10 A max.
    Earth terminal With earth wire
    Cable specifications VCTF oil-resistant cable, 4 cores, 3 m
    Nominal sectional area: 0.75 mm2
    Diameter: 7.6 dia.
    Ambient temperature Operating: -10 to 70 ℃ (with no icing)
    Ambient humidity 35 to 95 %
    Permissible operating frequency Electrical: 30 operations / 1 minute max.
    Mechanical: 120 operations / 1 minute max.
    Contact resistance (Initial value) 300 mΩ max.
    Insulation resistance 100 MΩ min. (at 500 VDC)
    Dielectric strength Between each terminal of the same polarities: 1,000 VAC 50/60 Hz 1 min
    Between live-metallic part and ground: 1,500 VAC 50/60 Hz 1 min
    Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz 1 min
    Impulse withstand voltage Between live-metallic part and ground: 2.5 kV
    Between each terminal and non-live-metallic part: 2.5 kV
    Durability Electrical: 200,000 operations min. (5 A at 125 VAC)
    Mechanical: 10 million operations min.
    Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
    Shock resistance Destruction: 1,000 m/s2 max.
    Malfunction: 500 m/s2 max.
    Degree of protection IP67
    Classification of protection against electric shock Class I (with earth wire)
    Operating Force (OF) Standard value 5.69 N max.
    Release Force (RF) Standard value 1.47 N min.
    Pre-Travel (PT) Standard value 25 ° max.
    Movement Differential (MD) Standard value 3 ° max.
    Over-Travel (OT) Standard value 40 ° mi