{"product_id":"model-digital-multimeter-dt4282-with-data-sheet-calibrati-on-certificate-tracebil-ity-1","title":"MODEL- DIGITAL  MULTIMETER-DT4282  WITH DATA SHEET  CALIBRATI ON  CERTIFICATE \u0026 TRACEBIL  ITY","description":"\u003cdiv id=\"specifications\" class=\"item js-tab-item set-tab-item current\" role=\"tabpanel\" aria-labelledby=\"tab-item3\"\u003e\n\u003ch2 class=\"hdg2-04\"\u003eBasic specifications\u003c\/h2\u003e\n\u003cdiv\u003eAccuracy guaranteed: 1 year\u003cbr\u003eRegarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.\u003c\/div\u003e\n\u003cdiv id=\"tablefield-wrapper-paragraph-32126-field_table_spec-0\" class=\"tablefield-wrapper\"\u003e\n\u003cdiv class=\"table-scroll-01\"\u003e\n\u003cdiv class=\"inner\"\u003e\n\u003ctable class=\"table-01\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_0 col_0\"\u003eDC Voltage range\u003c\/th\u003e\n\u003ctd class=\"row_0 col_1\" colspan=\"6\"\u003e60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_1 col_0\"\u003eAC Voltage(*1) range\u003c\/th\u003e\n\u003ctd class=\"row_1 col_1\" colspan=\"6\"\u003e60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz\u003cbr\u003eBasic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_2 col_0\"\u003eDC + AC Voltage(*1) range\u003c\/th\u003e\n\u003ctd class=\"row_2 col_1\" colspan=\"6\"\u003e6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz\u003cbr\u003eBasic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_3 col_0\"\u003eResistance range\u003c\/th\u003e\n\u003ctd class=\"row_3 col_1\" colspan=\"6\"\u003e60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)\u003cbr\u003eBasic accuracy: ±0.03 % rdg. ±2 dgt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_4 col_0\"\u003eDC Current range\u003c\/th\u003e\n\u003ctd class=\"row_4 col_1\" colspan=\"6\"\u003e600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_5 col_0\"\u003eAC Current(*1) range\u003c\/th\u003e\n\u003ctd class=\"row_5 col_1\" colspan=\"6\"\u003e600.00 μA to 10.000 A, 6 ranges,\u003cbr\u003eBasic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)\u003cbr\u003eFrequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_6 col_0\"\u003eAC Current(*1) range\u003cbr\u003e(use with Clamp on probes)\u003c\/th\u003e\n\u003ctd class=\"row_6 col_1\" colspan=\"6\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_7 col_0\"\u003ePeak\u003c\/th\u003e\n\u003ctd class=\"row_7 col_1\" colspan=\"6\"\u003eDC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)\u003cbr\u003eAC V, DC\/AC A measurement:\u003cbr\u003eSignal width 1 msec or more (single), 250 μsec or more (repeated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_8 col_0\"\u003eCapacitance range\u003c\/th\u003e\n\u003ctd class=\"row_8 col_1\" colspan=\"6\"\u003e1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_9 col_0\"\u003eContinuity Check\u003c\/th\u003e\n\u003ctd class=\"row_9 col_1\" colspan=\"6\"\u003eContinuity threshold: 20\/50\/100\/500 Ω, Response time: 10 ms or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_10 col_0\"\u003eDiode test\u003c\/th\u003e\n\u003ctd class=\"row_10 col_1\" colspan=\"6\"\u003eOpen terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_11 col_0\"\u003eFrequency range\u003c\/th\u003e\n\u003ctd class=\"row_11 col_1\" colspan=\"6\"\u003eAC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)\u003cbr\u003e99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_12 col_0\"\u003edB conversion\u003c\/th\u003e\n\u003ctd class=\"row_12 col_1\" colspan=\"6\"\u003eStandard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages\u003cbr\u003eDisplay dB conversion value of AC voltage (dBV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_13 col_0\"\u003eTemperature\u003cbr\u003e(thermocouples)\u003c\/th\u003e\n\u003ctd class=\"row_13 col_1\" colspan=\"6\"\u003eK: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)\u003cbr\u003eAdd accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_14 col_0\"\u003eOther functions\u003c\/th\u003e\n\u003ctd class=\"row_14 col_1\" colspan=\"6\"\u003eFilter function (remove harmonic noise, use only at 600 V AC, 1000 V AC ranges), display value hold, auto hold, MAX\/MIN value display, PEAK value display, relative value display, sampling setting, internal memory (400 data), auto-power save, USB communication (option), mis-insertion prevention shutters, decibel conversion, 4-20 mA percentage conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_15 col_0\"\u003eDisplay\u003c\/th\u003e\n\u003ctd class=\"row_15 col_1\" colspan=\"6\"\u003eMain and Sub displays: 5-digits LCD, max. 60000 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_16 col_0\"\u003eDisplay refresh rates\u003c\/th\u003e\n\u003ctd class=\"row_16 col_1\" colspan=\"6\"\u003e5 times\/s (Capacitance measurement: 0.05 to 2 times\/s, depending on measured value, Temperature: 1 time\/s )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_17 col_0\"\u003ePower supply\u003c\/th\u003e\n\u003ctd class=\"row_17 col_1\" colspan=\"6\"\u003eLR6 (AA) alkaline batteries ×4, Continuous use: 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_18 col_0\"\u003eDimensions and mass\u003c\/th\u003e\n\u003ctd class=\"row_18 col_1\" colspan=\"6\"\u003e93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_19 col_0\"\u003eIncluded accessories\u003c\/th\u003e\n\u003ctd class=\"row_19 col_1\" colspan=\"6\"\u003eTest Lead L9207-10(*2) ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul class=\"note-01\"\u003e\n\u003cli\u003e\n\u003cspan class=\"mark\"\u003e(*1)\u003c\/span\u003eZero-suppression: For small inputs below the guarantee range, zero is effectively displayed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"mark\"\u003e(*2)\u003c\/span\u003eReplaced by the probe L9300 starting with batches manufactured in March, 2025.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Industry Baba","offers":[{"title":"Default Title","offer_id":42693141495905,"sku":null,"price":31270.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0569\/0186\/1473\/files\/product_image5570.png?v=1765878899","url":"https:\/\/industrybaba.com\/products\/model-digital-multimeter-dt4282-with-data-sheet-calibrati-on-certificate-tracebil-ity-1","provider":"Industry Baba","version":"1.0","type":"link"}