MODEL- PLC 6ES7315-2EH14-0AB0(LASER WELDING )

Description

Product type designation CPU 315-2 PN/DP
HW functional status 01
Firmware version V3.2
Product function
● Isochronous mode Yes; Via PROFIBUS DP or PROFINET interface
Engineering with
● Programming package STEP 7 V5.5 or higher
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
external protection for power supply lines (recommendation) 2 A min.
Mains buffering
● Mains/voltage failure stored energy time 5 ms
● Repeat rate, min. 1 s
Input current
Current consumption (rated value) 750 mA
Current consumption (in no-load operation), typ. 150 mA
Inrush current, typ. 4 A
I²t 1 A²·s
Power loss
Power loss, typ. 4.65 W
Memory
Work memory
● integrated 384 kbyte
● expandable No
Load memory
● Plug-in (MMC) Yes
● Plug-in (MMC), max. 8 Mbyte
● Data management on MMC (after last programming), min. 10 a
Backup
● present Yes; Guaranteed by MMC (maintenance-free)
● without battery Yes; Program and data
CPU processing times
for bit operations, typ. 0.05 µs
for word operations, typ. 0.09 µs
for fixed point arithmetic, typ. 0.12 µs
for floating point arithmetic, typ. 0.45 µs
CPU-blocks
Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
● Number, max. 1 024; Number range: 1 to 16000
● Size, max. 64 kbyte
FB
● Number, max. 1 024; Number range: 0 to 7999
● Size, max. 64 kbyte
FC
● Number, max. 1 024; Number range: 0 to 7999
● Size, max. 64 kbyte
OB
● Size, max. 64 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Number of delay alarm OBs 2; OB 20, 21
● Number of cyclic interrupt OBs 4; OB 32, 33, 34, 35
● Number of process alarm OBs 1; OB 40
● Number of DPV1 alarm OBs 3; OB 55, 56, 57
● Number of isochronous mode OBs 1; OB 61
● Number of startup OBs 1; OB 100
● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
● Number of synchronous error OBs 2; OB 121, 122
Nesting depth
● per priority class 16
● additional within an error OB 4
Counters, timers and their retentivity
S7 counter
● Number 256
Retentivity
— adjustable Yes
— preset Z 0 to Z 7
Counting range
— adjustable Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
S7 times
● Number 256
Retentivity
— adjustable Yes
— preset No retentivity
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 128 kbyte
Flag
● Size, max. 2 048 byte
● Retentivity available Yes; MB 0 to MB 2 047
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8; 1 memory byte
Data blocks
● Retentivity adjustable Yes; via non-retain property on DB
● Retentivity preset Yes
Local data
● per priority class, max. 32 768 byte; Max. 2048 bytes per block
Address area
I/O address area
● Inputs 2 048 byte
● Outputs 2 048 byte
of which distributed
— Inputs 2 048 byte
— Outputs 2 048 byte
Process image
● Inputs 2 048 byte
● Outputs 2 048 byte
● Inputs, adjustable 2 048 byte
● Outputs, adjustable 2 048 byte
● Inputs, default 128 byte
● Outputs, default 128 byte
Subprocess images
● Number of subprocess images, max. 1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels
● Inputs 16 384
— of which central 1 024
● Outputs 16 384
— of which central 1 024
Analog channels
● Inputs 1 024
— of which central 256
● Outputs 1 024
— of which central 256
Hardware configuration
Number of expansion units, max. 3
Number of DP masters
● integrated 1
● via CP 4
Number of operable FMs and CPs (recommended)
● FM 8
● CP, PtP 8
● CP, LAN 10
Rack
● Racks, max. 4
● Modules per rack, max. 8
Time of day
Clock
● Hardware clock (real-time) Yes
● retentive and synchronizable Yes
● Backup time 6 wk; At 40 °C ambient temperature
● Deviation per day, max. 10 s; Typ.: 2 s
● Behavior of the clock following POWER-ON Clock continues running after POWER OFF
● Behavior of the clock following expiry of backup period the clock continues at the time of day it had when power was switched off
Operating hours counter
● Number 1
● Number/Number range 0
● Range of values 0 to 2^31 hours (when using SFC 101)
● Granularity 1 h
● retentive Yes; Must be restarted at each restart
Clock synchronization
● supported Yes
● to MPI, master Yes
● on MPI, device Yes
● to DP, master Yes; With DP slave only slave clock
● on DP, device Yes
● in AS, master Yes
● in AS, device Yes
● on Ethernet via NTP Yes; As client
Digital inputs
Number of digital inputs 0
Digital outputs
Number of digital outputs 0
Analog inputs
Number of analog inputs 0
Interfaces
Number of PROFINET interfaces 1; 2 ports (switch) RJ45
Number of RS 485 interfaces 1; Combined MPI / PROFIBUS DP
Number of RS 422 interfaces 0
1. Interface
Interface type Integrated RS 485 interface
Isolated Yes
Interface types
● RS 485 Yes
● Output current of the interface, max. 200 mA
Protocols
● MPI Yes
● PROFIBUS DP master Yes
● PROFIBUS DP device Yes
● Point-to-point connection No
MPI
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client No; but via CP and loadable FB
— S7 communication, as server Yes
PROFIBUS DP master
● Transmission rate, max. 12 Mbit/s
● max. number of DP devices 124
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes; I blocks only
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Equidistance Yes
— Isochronous mode Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
— SYNC/FREEZE Yes
— activation/deactivation of DP devices Yes
— max. number of DP devices that can be activated/deactivated at the same time 8
— Direct data exchange (slave-to-slave communication) Yes; as subscriber
— DPV1 Yes
Address area
— Inputs, max. 2 kbyte
— Outputs, max. 2 kbyte
User data per DP device
— Inputs, max. 244 byte
— Outputs, max. 244 byte
PROFIBUS DP device
● Transmission rate, max. 12 Mbit/s
● automatic baud rate search Yes; only with passive interface
● Address area, max. 32
● User data per address area, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes; Only with active interface
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes; Connection configured on one side only
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
2. Interface
Interface type PROFINET
Isolated Yes
automatic detection of transmission rate Yes; 10/100 Mbit/s
Autonegotiation Yes
Autocrossing Yes
Change of IP address at runtime, supported Yes
Interface types
● RJ 45 (Ethernet) Yes
● Number of ports 2
● integrated switch Yes
Protocols
● MPI No
● PROFINET IO Controller Yes; Also simultaneously with IO-Device functionality
● PROFINET IO Device Yes; Also simultaneously with IO Controller functionality
● PROFINET CBA Yes
● PROFIBUS DP master No
● PROFIBUS DP device No
● Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP
● Web server Yes
● Media redundancy Yes
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— S7 communication Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
— Isochronous mode Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
— IRT Yes
— Shared device Yes
— Prioritized startup Yes
— Number of IO devices with prioritized startup, max. 32
— Number of connectable IO Devices, max. 128
— Of which IO devices with IRT, max. 64
— of which in line, max. 64
— Number of IO Devices with IRT and the option "high flexibility" 128
— of which in line, max. 61
— Number of connectable IO Devices for RT, max. 128
— of which in line, max. 128
— Activation/deactivation of IO Devices Yes
— Number of IO Devices that can be simultaneously activated/deactivated, max. 8
— IO Devices changing during operation (partner ports), supported Yes
— Number of IO Devices per tool, max. 8
— Device replacement without swap medium Yes
— Send cycles 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
— Updating time 250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, technical Data" for more details)
Address area
— Inputs, max. 2 kbyte
— Outputs, max. 2 kbyte
— User data consistency, max. 1 024 byte
PROFINET IO Device
Services
— PG/OP communication Yes
— Routing Yes
— S7 communication Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
— Isochronous mode No
— IRT Yes
— PROFIenergy Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
— Shared device Yes
— Number of IO Controllers with shared device, max. 2
Transfer memory
— Inputs, max. 1 440 byte; Per IO Controller with shared device
— Outputs, max. 1 440 byte; Per IO Controller with shared device
Submodules
— Number, max. 64
— User data per submodule, max. 1 024 byte
PROFINET CBA
● acyclic transmission Yes
● cyclic transmission Yes
Open IE communication
● Number of connections, max. 8
● Local port numbers used at the system end 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
● Keep-alive function, supported Yes
Protocols
PROFIsafe No
Redundancy mode
Media redundancy
— Switchover time on line break, typ. 200 ms; PROFINET MRP
— Number of stations in the ring, max. 50
Open IE communication
● TCP/IP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8
— Data length for connection type 01H, max. 1 460 byte
— Data length for connection type 11H, max. 32 768 byte
— several passive connections per port, supported Yes
● ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8
— Data length, max. 32 768 byte
● UDP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8
— Data length, max. 1 472 byte
Web server
● supported Yes
● User-defined websites Yes
● Number of HTTP clients 5
Communication functions
PG/OP communication Yes
Data record routing Yes
Global data communication
● supported Yes
● Number of GD loops, max. 8
● Number of GD packets, max. 8
● Number of GD packets, transmitter, max. 8
● Number of GD packets, receiver, max. 8
● Size of GD packets, max. 22 byte
● Size of GD packet (of which consistent), max. 22 byte
S7 basic communication
● supported Yes
● User data per job, max. 76 byte
● User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
● supported Yes
● as server Yes
● as client Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
● User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
● supported Yes; via CP and loadable FC
PROFINET CBA (at set setpoint communication load)
● Setpoint for the CPU communication load 50 %
● Number of remote interconnection partners 32
● number of master/device functions 30
● total of all master/device connections 1 000
● data length of all incoming master/device connections, max. 4 000 byte
● data length of all outgoing master/device connections, max. 4 000 byte
● Number of device-internal and PROFIBUS interconnections 500
● Data length of device-internal und PROFIBUS interconnections, max. 4 000 byte
● Data length per connection, max. 1 400 byte

MODEL- PLC 6ES7315-2EH14-0AB0(LASER WELDING )

Product form

Product type designation CPU 315-2 PN/DP HW functional status 01 Firmware version V3.2 Product function ● Isochronous mode Yes; Via... Read more

Rs. 185,000.00 Excl. VAT

    Description

    Product type designation CPU 315-2 PN/DP
    HW functional status 01
    Firmware version V3.2
    Product function
    ● Isochronous mode Yes; Via PROFIBUS DP or PROFINET interface
    Engineering with
    ● Programming package STEP 7 V5.5 or higher
    Supply voltage
    Rated value (DC) 24 V
    permissible range, lower limit (DC) 20.4 V
    permissible range, upper limit (DC) 28.8 V
    external protection for power supply lines (recommendation) 2 A min.
    Mains buffering
    ● Mains/voltage failure stored energy time 5 ms
    ● Repeat rate, min. 1 s
    Input current
    Current consumption (rated value) 750 mA
    Current consumption (in no-load operation), typ. 150 mA
    Inrush current, typ. 4 A
    I²t 1 A²·s
    Power loss
    Power loss, typ. 4.65 W
    Memory
    Work memory
    ● integrated 384 kbyte
    ● expandable No
    Load memory
    ● Plug-in (MMC) Yes
    ● Plug-in (MMC), max. 8 Mbyte
    ● Data management on MMC (after last programming), min. 10 a
    Backup
    ● present Yes; Guaranteed by MMC (maintenance-free)
    ● without battery Yes; Program and data
    CPU processing times
    for bit operations, typ. 0.05 µs
    for word operations, typ. 0.09 µs
    for fixed point arithmetic, typ. 0.12 µs
    for floating point arithmetic, typ. 0.45 µs
    CPU-blocks
    Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
    DB
    ● Number, max. 1 024; Number range: 1 to 16000
    ● Size, max. 64 kbyte
    FB
    ● Number, max. 1 024; Number range: 0 to 7999
    ● Size, max. 64 kbyte
    FC
    ● Number, max. 1 024; Number range: 0 to 7999
    ● Size, max. 64 kbyte
    OB
    ● Size, max. 64 kbyte
    ● Number of free cycle OBs 1; OB 1
    ● Number of time alarm OBs 1; OB 10
    ● Number of delay alarm OBs 2; OB 20, 21
    ● Number of cyclic interrupt OBs 4; OB 32, 33, 34, 35
    ● Number of process alarm OBs 1; OB 40
    ● Number of DPV1 alarm OBs 3; OB 55, 56, 57
    ● Number of isochronous mode OBs 1; OB 61
    ● Number of startup OBs 1; OB 100
    ● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
    ● Number of synchronous error OBs 2; OB 121, 122
    Nesting depth
    ● per priority class 16
    ● additional within an error OB 4
    Counters, timers and their retentivity
    S7 counter
    ● Number 256
    Retentivity
    — adjustable Yes
    — preset Z 0 to Z 7
    Counting range
    — adjustable Yes
    — lower limit 0
    — upper limit 999
    IEC counter
    ● present Yes
    ● Type SFB
    ● Number Unlimited (limited only by RAM capacity)
    S7 times
    ● Number 256
    Retentivity
    — adjustable Yes
    — preset No retentivity
    Time range
    — lower limit 10 ms
    — upper limit 9 990 s
    IEC timer
    ● present Yes
    ● Type SFB
    ● Number Unlimited (limited only by RAM capacity)
    Data areas and their retentivity
    Retentive data area (incl. timers, counters, flags), max. 128 kbyte
    Flag
    ● Size, max. 2 048 byte
    ● Retentivity available Yes; MB 0 to MB 2 047
    ● Retentivity preset MB 0 to MB 15
    ● Number of clock memories 8; 1 memory byte
    Data blocks
    ● Retentivity adjustable Yes; via non-retain property on DB
    ● Retentivity preset Yes
    Local data
    ● per priority class, max. 32 768 byte; Max. 2048 bytes per block
    Address area
    I/O address area
    ● Inputs 2 048 byte
    ● Outputs 2 048 byte
    of which distributed
    — Inputs 2 048 byte
    — Outputs 2 048 byte
    Process image
    ● Inputs 2 048 byte
    ● Outputs 2 048 byte
    ● Inputs, adjustable 2 048 byte
    ● Outputs, adjustable 2 048 byte
    ● Inputs, default 128 byte
    ● Outputs, default 128 byte
    Subprocess images
    ● Number of subprocess images, max. 1; With PROFINET IO, the length of the user data is limited to 1600 bytes
    Digital channels
    ● Inputs 16 384
    — of which central 1 024
    ● Outputs 16 384
    — of which central 1 024
    Analog channels
    ● Inputs 1 024
    — of which central 256
    ● Outputs 1 024
    — of which central 256
    Hardware configuration
    Number of expansion units, max. 3
    Number of DP masters
    ● integrated 1
    ● via CP 4
    Number of operable FMs and CPs (recommended)
    ● FM 8
    ● CP, PtP 8
    ● CP, LAN 10
    Rack
    ● Racks, max. 4
    ● Modules per rack, max. 8
    Time of day
    Clock
    ● Hardware clock (real-time) Yes
    ● retentive and synchronizable Yes
    ● Backup time 6 wk; At 40 °C ambient temperature
    ● Deviation per day, max. 10 s; Typ.: 2 s
    ● Behavior of the clock following POWER-ON Clock continues running after POWER OFF
    ● Behavior of the clock following expiry of backup period the clock continues at the time of day it had when power was switched off
    Operating hours counter
    ● Number 1
    ● Number/Number range 0
    ● Range of values 0 to 2^31 hours (when using SFC 101)
    ● Granularity 1 h
    ● retentive Yes; Must be restarted at each restart
    Clock synchronization
    ● supported Yes
    ● to MPI, master Yes
    ● on MPI, device Yes
    ● to DP, master Yes; With DP slave only slave clock
    ● on DP, device Yes
    ● in AS, master Yes
    ● in AS, device Yes
    ● on Ethernet via NTP Yes; As client
    Digital inputs
    Number of digital inputs 0
    Digital outputs
    Number of digital outputs 0
    Analog inputs
    Number of analog inputs 0
    Interfaces
    Number of PROFINET interfaces 1; 2 ports (switch) RJ45
    Number of RS 485 interfaces 1; Combined MPI / PROFIBUS DP
    Number of RS 422 interfaces 0
    1. Interface
    Interface type Integrated RS 485 interface
    Isolated Yes
    Interface types
    ● RS 485 Yes
    ● Output current of the interface, max. 200 mA
    Protocols
    ● MPI Yes
    ● PROFIBUS DP master Yes
    ● PROFIBUS DP device Yes
    ● Point-to-point connection No
    MPI
    ● Transmission rate, max. 12 Mbit/s
    Services
    — PG/OP communication Yes
    — Routing Yes
    — Global data communication Yes
    — S7 basic communication Yes
    — S7 communication Yes
    — S7 communication, as client No; but via CP and loadable FB
    — S7 communication, as server Yes
    PROFIBUS DP master
    ● Transmission rate, max. 12 Mbit/s
    ● max. number of DP devices 124
    Services
    — PG/OP communication Yes
    — Routing Yes
    — Global data communication No
    — S7 basic communication Yes; I blocks only
    — S7 communication Yes
    — S7 communication, as client No
    — S7 communication, as server Yes
    — Equidistance Yes
    — Isochronous mode Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
    — SYNC/FREEZE Yes
    — activation/deactivation of DP devices Yes
    — max. number of DP devices that can be activated/deactivated at the same time 8
    — Direct data exchange (slave-to-slave communication) Yes; as subscriber
    — DPV1 Yes
    Address area
    — Inputs, max. 2 kbyte
    — Outputs, max. 2 kbyte
    User data per DP device
    — Inputs, max. 244 byte
    — Outputs, max. 244 byte
    PROFIBUS DP device
    ● Transmission rate, max. 12 Mbit/s
    ● automatic baud rate search Yes; only with passive interface
    ● Address area, max. 32
    ● User data per address area, max. 32 byte
    Services
    — PG/OP communication Yes
    — Routing Yes; Only with active interface
    — Global data communication No
    — S7 basic communication No
    — S7 communication Yes
    — S7 communication, as client No
    — S7 communication, as server Yes; Connection configured on one side only
    — Direct data exchange (slave-to-slave communication) Yes
    — DPV1 No
    Transfer memory
    — Inputs 244 byte
    — Outputs 244 byte
    2. Interface
    Interface type PROFINET
    Isolated Yes
    automatic detection of transmission rate Yes; 10/100 Mbit/s
    Autonegotiation Yes
    Autocrossing Yes
    Change of IP address at runtime, supported Yes
    Interface types
    ● RJ 45 (Ethernet) Yes
    ● Number of ports 2
    ● integrated switch Yes
    Protocols
    ● MPI No
    ● PROFINET IO Controller Yes; Also simultaneously with IO-Device functionality
    ● PROFINET IO Device Yes; Also simultaneously with IO Controller functionality
    ● PROFINET CBA Yes
    ● PROFIBUS DP master No
    ● PROFIBUS DP device No
    ● Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP
    ● Web server Yes
    ● Media redundancy Yes
    PROFINET IO Controller
    ● Transmission rate, max. 100 Mbit/s
    Services
    — PG/OP communication Yes
    — Routing Yes
    — S7 communication Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
    — Isochronous mode Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
    — IRT Yes
    — Shared device Yes
    — Prioritized startup Yes
    — Number of IO devices with prioritized startup, max. 32
    — Number of connectable IO Devices, max. 128
    — Of which IO devices with IRT, max. 64
    — of which in line, max. 64
    — Number of IO Devices with IRT and the option "high flexibility" 128
    — of which in line, max. 61
    — Number of connectable IO Devices for RT, max. 128
    — of which in line, max. 128
    — Activation/deactivation of IO Devices Yes
    — Number of IO Devices that can be simultaneously activated/deactivated, max. 8
    — IO Devices changing during operation (partner ports), supported Yes
    — Number of IO Devices per tool, max. 8
    — Device replacement without swap medium Yes
    — Send cycles 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
    — Updating time 250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, technical Data" for more details)
    Address area
    — Inputs, max. 2 kbyte
    — Outputs, max. 2 kbyte
    — User data consistency, max. 1 024 byte
    PROFINET IO Device
    Services
    — PG/OP communication Yes
    — Routing Yes
    — S7 communication Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
    — Isochronous mode No
    — IRT Yes
    — PROFIenergy Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
    — Shared device Yes
    — Number of IO Controllers with shared device, max. 2
    Transfer memory
    — Inputs, max. 1 440 byte; Per IO Controller with shared device
    — Outputs, max. 1 440 byte; Per IO Controller with shared device
    Submodules
    — Number, max. 64
    — User data per submodule, max. 1 024 byte
    PROFINET CBA
    ● acyclic transmission Yes
    ● cyclic transmission Yes
    Open IE communication
    ● Number of connections, max. 8
    ● Local port numbers used at the system end 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
    ● Keep-alive function, supported Yes
    Protocols
    PROFIsafe No
    Redundancy mode
    Media redundancy
    — Switchover time on line break, typ. 200 ms; PROFINET MRP
    — Number of stations in the ring, max. 50
    Open IE communication
    ● TCP/IP Yes; via integrated PROFINET interface and loadable FBs
    — Number of connections, max. 8
    — Data length for connection type 01H, max. 1 460 byte
    — Data length for connection type 11H, max. 32 768 byte
    — several passive connections per port, supported Yes
    ● ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface and loadable FBs
    — Number of connections, max. 8
    — Data length, max. 32 768 byte
    ● UDP Yes; via integrated PROFINET interface and loadable FBs
    — Number of connections, max. 8
    — Data length, max. 1 472 byte
    Web server
    ● supported Yes
    ● User-defined websites Yes
    ● Number of HTTP clients 5
    Communication functions
    PG/OP communication Yes
    Data record routing Yes
    Global data communication
    ● supported Yes
    ● Number of GD loops, max. 8
    ● Number of GD packets, max. 8
    ● Number of GD packets, transmitter, max. 8
    ● Number of GD packets, receiver, max. 8
    ● Size of GD packets, max. 22 byte
    ● Size of GD packet (of which consistent), max. 22 byte
    S7 basic communication
    ● supported Yes
    ● User data per job, max. 76 byte
    ● User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
    S7 communication
    ● supported Yes
    ● as server Yes
    ● as client Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
    ● User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
    S5 compatible communication
    ● supported Yes; via CP and loadable FC
    PROFINET CBA (at set setpoint communication load)
    ● Setpoint for the CPU communication load 50 %
    ● Number of remote interconnection partners 32
    ● number of master/device functions 30
    ● total of all master/device connections 1 000
    ● data length of all incoming master/device connections, max. 4 000 byte
    ● data length of all outgoing master/device connections, max. 4 000 byte
    ● Number of device-internal and PROFIBUS interconnections 500
    ● Data length of device-internal und PROFIBUS interconnections, max. 4 000 byte
    ● Data length per connection, max. 1 400 byte