| Power rating |
15 W |
| Output voltage |
5 VDC |
| Efficiency |
76 % typ. (at 100 VAC input) 76 % typ. (at 200 VAC input) |
| Input |
Rated input voltage |
100 to 240 VAC |
| Allowable input voltage variable range |
85 to 264 VAC (Single-phase) 90 to 350 VDC |
| Frequency |
50/60Hz (47 to 450 Hz) |
| Rated input current |
0.35 A typ. (at 100 VAC input) 0.25 A typ. (at 200 VAC input) |
| Leakage current |
0.5 mA max. (at 100 VAC input) 1.0 mA max. (at 200 VAC input) |
| Inrush current (cold start at 25 ℃) |
16 A typ. (at 100 VAC input) 32 A typ. (at 200 VAC input) |
| Output |
Rated output current |
3 A |
| Output voltage variable range |
-10 to +15 % With V.ADJ |
| Maximum peak current |
3.6 A |
| Ripple |
60 mV(p-p) max. at 20 MHz |
| Static input variation influence |
0.4 % max. |
| Static load variation influence |
0.8 % max. |
| Ambient temperature variation influence |
0.05 %/℃ max. |
| Start up time |
600 ms typ. (at 100 VAC input) 400 ms typ. (at 200 VAC input) |
| Hold time |
20 ms typ. (at 100 VAC input) 100 ms typ. (at 200 VAC input) |
| Additional functions |
Overload protection |
Yes, automatic reset |
| Overvoltage protection |
Yes, Shut off the input voltage and turn on the input again |
| Series operation |
Yes (Up to 2 Power Supplies with external diode) |
| Parallel operation |
Yes (Up to 2 Power Supplies) |
| Output indicator |
Yes (color: green, lighting from 80 to 90% or more of rated voltage) |
| Insulation |
Dielectric strength |
Between all input terminals and all output terminals: 3 kVAC for 1 min, Cut-off current: 20 mA Between all input terminals and PE terminals: 2 kVAC for 1 min, Cut-off current: 20 mA Between all output terminals and PE terminals: 1 kVAC for 1 min, Cut-off current: 20 mA |
| Insulation resistance |
Between all output terminals and all input terminals/ PE terminals: 100 MΩ min., at 500 VDC |
| Environment |
Vibration resistance |
10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours |
| Shock resistance |
150 m/s2, in each 6 directions 3 times |
| Ambient temperature (Operating) |
-40 to 70 ℃ (with no freezing or condensation) |
| Ambient temperature (Storage) |
-40 to 85 ℃ (with no freezing or condensation) |
| Ambient humidity (Operating) |
95 %RH max. |
| Ambient humidity (Storage) |
95 %RH max. |
| Reliability |
MTBF |
135,000 hours min. |
| Life expectancy |
10 years (at rated input, a load rate of 50% load, under the temperature of 40 ℃, standard mounting) |
| Construction |
Construction |
Covered type |
| Connection |
Terminal blocks |
| Terminal type |
Rod terminal |
| Mounting |
DIN track mounting |
| Cooling fan |
Cooling fan No |
| Degree of protection |
IP20, EN/IEC 60529 |
| Weight (Main) |
150 g max. |