| Contact resistance |
30 mΩ max. (Voltage drop method with 5 VDC 1 A) |
| Operating time |
15 ms max. (With rated operating power applied, not including contact bounce) |
| Reset time |
5 ms max. (With rated operating power applied, not including contact bounce) |
| Maximum operating frequency |
Mechanical: 18000 time/hour Rated load: 1800 time/hour |
| Insulation resistance |
Between coil and contacts: 1000 MΩ min. (at 500 VDC) Between contacts of same polarity: 1000 MΩ min. (at 500 VDC) |
| Dielectric strength |
Between coil and contacts: 5000 VAC 50/60 Hz 1 min Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min |
| Vibration resistance (destruction) |
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
| Vibration resistance (Malfunction) |
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
| Shock resistance (destruction) |
1000 m/s2
|
| Shock resistance (Malfunction) |
Energized: 200 m/s2 No energized: 100 m/s2
|
| Endurance (Mechanical) |
20 million operations min. (switching frequency 18,000 operations/h) |
| Endurance (Electrical) |
100,000 operations min. (Rated load, switching frequency 1,800 operations/h) |
| Failure rate |
100 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute) |
| Ambient temperature (Operating) |
-40 to 70 ℃ (with no freezing or condensation) |
| Ambient humidity (Operating) |
5 to 85 % |
| Weight |
Approx. 20 g |
| Mounting method |
Socket |
| Applicable socket |
P2RFZ-05/ P2RFZ-05-E/ P2RF-05-PU/ P2R-057P/ P2R-05A/ P2R-05P |