Power rating |
120 W |
Output voltage |
24 VDC |
Efficiency |
84 % typ. (at 100 VAC input) 87 % typ. (at 200 VAC input) |
Input |
Rated input voltage |
100 to 240 VAC |
Allowable input voltage variable range |
85 to 264 VAC 80 to 370 VDC |
Frequency |
50/60Hz (47 to 63 Hz) |
Rated input current |
1.9 A max., 1.5 A typ. (at 100 VAC input) 1.1 A max., 0.71 A typ. (at 200 VAC input) |
Power factor |
0.9 min. |
Leakage current |
0.5 mA max. (at 100 VAC input) 1.0 mA max. (at 200 VAC input) |
Inrush current (cold start at 25 ℃) |
17.5 A max., 14 A typ. (at 100 VAC input) 35 A max., 28 A typ. (at 200 VAC input) |
Output |
Rated output current |
5 A |
Output voltage variable range |
-10 to +15 % With V.ADJ |
Ripple |
60 mV max. |
Static input variation influence |
0.5 % max. (at 100% load) |
Static load variation influence |
1.5 % max. (at rated input, 0 to 100% load) |
Ambient temperature variation influence |
0.05 %/℃ max. |
Start up time |
550 ms typ. (at 100 VAC input) 430 ms typ. (at 200 VAC input) |
Hold time |
52 ms typ. (at 100 VAC input) 54 ms typ. (at 200 VAC input) |
Additional functions |
Overload protection |
Yes, automatic reset |
Overvoltage protection |
Yes, Shut off the input voltage and turn on the input again |
Series operation |
Yes (Up to 2 Power Supplies with external diode) |
Parallel operation |
No (However, backup operation is possible, external diodes required.) |
Output indicator |
Yes (color: green) |
Insulation |
Dielectric strength |
Between all input terminals and PE terminals: 2 kVAC for 1 min, Detection current: 20 mA Between all input terminals and all output terminals/alarm outputs: 3 kVAC for 1 min, Detection current: 20 mA Between all output terminals/alarm outputs and all PE terminals: 1 kVAC for 1 min, Detection current: 30 mA Between all output terminals and all alarm outputs: 500 VAC for 1 min, Detection current: 20 mA |
Insulation resistance |
Between all output terminals/alarm outputs and all input terminals/PE terminals: 100 MΩ min., at 500 VDC |
Environment |
Vibration resistance |
10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours |
Shock resistance |
150 m/s2, in each 6 directions 3 times |
Ambient temperature (Operating) |
-10 to 60 ℃ |
Ambient temperature (Storage) |
-25 to 65 ℃ |
Ambient humidity (Operating) |
25 to 85 % |
Ambient humidity (Storage) |
25 to 90 % |
Reliability |
Life expectancy |
10 years (at rated input, a load rate of 50% load, under the temperature of 40 ℃, standard mounting) |
Construction |
Construction |
Covered type |
Connection |
Terminal blocks |
Terminal type |
Screw terminal |
Mounting |
DIN track mounting |
Attachment |
Terminal block cover |
Weight (Main) |
550 g max. |