| Size |
M12 |
| Mounting type |
Shielded |
| Sensing Distance |
4 mm |
| Setting distance |
0 to 3.2 mm |
| Output type |
PNP |
| Operation mode |
NO |
| Power supply |
12 to 24 VDC |
| Connection method |
M12 connector |
| Body Length |
Short body |
| Body material |
Brass |
| Thread Length |
34 mm |
| Overall Length |
48 mm |
| Differential travel |
10% max. of sensing distance |
| Detectable object |
Ferrous metal (The sensing distance decreases with non-ferrous metal.) |
| Standard target |
12×12×1 mm |
| Response frequency |
1,000 Hz |
| Current consumption |
10 mA max |
| Indicator |
Operation indicator (Yellow LED) |
| Protection circuit |
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection |
| Ambient temperature range |
Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation) |
| Ambient humidity |
Operating: 35% to 95%, Storage: 35% to 95% |
| Temperature influence |
±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C ±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C |
| Voltage influence |
±1% max. of sensing distance in rated voltage range ±15% |
| Insulation resistance |
50 MΩ min. (at 500 VDC) between current carry parts and case |
| Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case |
| Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
| Shock resistance |
1,000 m/s2, 10 times each in X, Y and Z directions |
| Degree of protection |
IP67 |
| Weight |
Approx. 35 g |