quint-ups /24dc/24dc/5 1.3A 2320254 phoenix contact

Description

QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - Uninterruptible power supply

Uninterruptible power supply with IQ Technology and integrated battery for DIN rail mounting, input: 24 V DC, output: 24 V DC/5 A, battery: lead AGM 1.2 Ah, including mounted universal DIN rail adapter UTA 107/30

  • Easy handling thanks to automatic battery detection, tool-free battery replacement during operation, and communication via the IFS interface
  • Reliable starting of difficult loads with the static POWER BOOST power reserve with up to 1.5 times the nominal current permanently
  • Fast tripping of standard circuit breakers with SFB (selective fuse breaking) technology
  • Device suitable for universal use thanks to comprehensive license package and extensive parameterization and diagnostics options

QUINT-UPS


The Phoenix Contact QUINT-UPS Series comprises uninterruptible power supplies (UPS) designed to ensure maximum system availability in industrial applications. These UPS modules feature IQ Technology for intelligent battery management, ensuring reliable power backup during mains failures. Key Features: IQ Technology: Provides real-time monitoring of the energy storage status, including parameters like voltage, current, and temperature, enabling predictive maintenance and optimal battery usage. DIN Rail Mounting: Designed for easy integration into control cabinets with standard DIN rail mounting, facilitating straightforward installation and maintenance. Wide Range of Models: Available in various configurations to meet different power requirements, with input and output voltages typically at 24 V DC and output currents ranging from 5 A to 20 A.
Technical Specifications

General

Note on the battery This product contains a battery with a limited shelf life that must be charged every few months. The product packaging indicates when the battery must be started up or recharged. The general shelf life can be found in the technical data area under “Latest startup”.

DC operation

Input Voltage 24 V DC
Input voltage range 18 V DC ... 30 V DC
Input voltage range DC 18 V DC ... 30 V DC
Voltage type of supply voltage DC
Buffer period 50 min. (1 A)
Buffer period 5 min. (5 A)
Current consumption 9.3 A (24 V DC)
Current consumption 9.7 mA
Current consumption 1.7 A
Current consumption 7 A
Fixed backup threshold ≤ 22.6 V DC

Output data

Efficiency > 97.1 % (Mains operation, with charged energy storage)
Efficiency 97.31 %
Nominal Output Voltage 24 V DC
Output voltage range 18 V DC ... 30 V DC
Nominal output current (IN) 5 A (0 °C ... 40 °C)
Output current limit > 7.5 A (Battery operation)
Bridging time 360 s
Derating 60 °C ... 70 °C (2.5 %/K)
Output Power 120 W
Power dissipation 2.5 W (Mains operation)
Power dissipation 2.7 W (Mains operation)
Power dissipation 1.9 W (Mains operation)
Power dissipation 3.3 W (Battery operation)
Power dissipation 3.3 W (Battery operation)
Power dissipation 4.1 W (Battery operation)
Output fuse 1x 15 A
Connection in parallel 2
Connection in series No

Mains operation

Nominal Output Voltage 24 V DC
Output voltage range 18 V DC ... 30 V DC (UOUT = UIN - 0,1 V DC)
Nominal output current (IN) 5 A (0 °C ... 40 °C)
POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB) 30 A (0 °C ... 40 °C)
Duration 12 ms (SFB technology)

Battery operation

Nominal Output Voltage 24 V DC
Output voltage range 19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
Nominal output current (IN) 5 A (0 °C ... 40 °C)
POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB) 32.5 A (0 °C ... 40 °C)
Duration 15 ms (SFB technology)

Signal: Alarm

Output description Relay
Output Voltage ≤ 30 V AC/DC
Continuous load current ≤ 100 mA

Signal: Battery charge

Output description Relay
Output Voltage ≤ 30 V AC/DC
Continuous load current ≤ 100 mA

Signal: Battery mode

Output description Relay
Output Voltage ≤ 30 V AC/DC
Continuous load current ≤ 100 mA

Signal

Continuous load current ≤ 200 mA

Energy storage

Nominal voltage UN 24 V DC
End-of-charge voltage 24 V DC ... 29 V DC (temperature compensated)
Charging current 0.36 A
Nominal capacity 1.2 Ah
Buffer period 50 min. (1 A)
Buffer period 5 min. (5 A)
Latest startup date (battery only) 3 Months (0 °C ... 20 °C)
Latest startup date (battery only) 1 Months (30 °C ... 40 °C)
Latest startup (battery only) - range 1 Months ... 3 Months (20 °C ... 30 °C)
Battery technology VRLA-AGM
Memory medium VRLA-AGM Battery 1.2 Ah
Accumulator type 2x BB Battery BP1.2-12FR (from UPS V/C-level 05)
IQ Technology Yes
Temperature sensor yes
Network management Yes

Input

Connection Method Screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 20
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M4
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm

Output

Connection Method Screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 20
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M4
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm

Signal

Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M4
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm

Interfaces

Interface IFS (Interface system data port)

Signaling

Types of signaling LED
Types of signaling Relay contact
Types of signaling Interface/software

Signal output

Signalization designation Power In OK
Status display LED
Note on status display static on
Note on status display static on

Signal output: Switching output

Signalization designation Alarm
Status display LED
Note on status display static on
Color red
Note on status display static on
Signalization designation Battery charge
Status display LED bar graph
Note on status display dynamic
Color red/green
Note on status display dynamic
Signalization designation Battery mode
Status display LED
Note on status display static on
Color yellow
Note on status display static on

Product properties

Product family QUINT UPS ‒ UPS with integrated battery
Disposal Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations.
IQ Technology Yes
MTBF (IEC 61709, SN 29500) > 806000 h (40 °C)

Insulation characteristics

Protection class III
Degree of pollution 2

Life expectancy (electrolytic capacitors)

Time 316800 h

Dimensions

Width 88 mm
Height 138 mm
Depth 125 mm

Installation dimensions

Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm

Mounting

Mounting Type DIN rail mounting
Assembly instructions alignable: horizontal 5 mm, vertical 50 mm
Mounting Position horizontal DIN rail NS 35, EN 60715

Material specifications

Housing Material Metal
Housing Material Steel sheet, zinc-plated
Type of housing Steel sheet, zinc-plated
Side element version Galvanized sheet steel, closed

Ambient conditions

Degree of Protection IP20
Ambient temperature (storage/transport) -20 °C ... 40 °C
Ambient temperature (charge) 0 °C ... 40 °C
Ambient temperature (discharge) -20 °C ... 50 °C
Climatic class 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation) ≤ 95 % (25 °C, non-condensing)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (Operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Vibration (Operation) 15 Hz ... 150 Hz, 2.3g tv = 90 min.

Standards and Regulations

Rail applications EN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard - Electrical safety EN 61558-2-17

Approvals

UL approvals UL/C-UL Recognized UL 60950-1
UL approvals UL Listed UL 508

EMC data

Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission EN 61000-6-3
EMC requirements for noise emission EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EMC requirements for noise immunity EN 61000-6-2
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU

Electrostatic discharge

Standards/regulations EN 61000-4-2
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Comments Criterion A

Electromagnetic HF field

Standards/regulations EN 61000-4-3
Frequency Range 80 MHz ... 1 GHz
Test field strength 20 V/m
Frequency Range 1 GHz ... 2 GHz
Test field strength 10 V/m
Frequency Range 2 GHz ... 3 GHz
Test field strength 3 V/m
Comments Criterion A

Fast transients (burst)

Standards/regulations EN 61000-4-4
Input 2 kV (Test Level 3 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Comments Criterion A

Surge voltage load (surge)

Standards/regulations EN 61000-4-5
Input 0.5 kV (Test Level 1 - symmetrical)
Input 0.5 kV (Test Level 1 - asymmetrical)
Output 0.5 kV (Test Level 1 - symmetrical)
Output 0.5 kV (Test Level 1 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion B

Conducted interference

Standards/regulations EN 61000-4-6
I/O/S asymmetrical
Frequency Range 0.15 MHz ... 80 MHz
Comments Criterion A
Voltage 10 V (Test Level 3)

Emitted interference

Standards/regulations EN 61000-6-3
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential

Criteria

Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.

quint-ups /24dc/24dc/5 1.3A 2320254 phoenix contact

Product form

QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - Uninterruptible power supply Uninterruptible power supply with IQ Technology and integrated battery for DIN rail... Read more

Rs. 31,417.00 Excl. VAT

  • Shipped today? Order within: Jul 01, 2026 17:00:00 -0400

    Description

    QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - Uninterruptible power supply

    Uninterruptible power supply with IQ Technology and integrated battery for DIN rail mounting, input: 24 V DC, output: 24 V DC/5 A, battery: lead AGM 1.2 Ah, including mounted universal DIN rail adapter UTA 107/30

    • Easy handling thanks to automatic battery detection, tool-free battery replacement during operation, and communication via the IFS interface
    • Reliable starting of difficult loads with the static POWER BOOST power reserve with up to 1.5 times the nominal current permanently
    • Fast tripping of standard circuit breakers with SFB (selective fuse breaking) technology
    • Device suitable for universal use thanks to comprehensive license package and extensive parameterization and diagnostics options

    QUINT-UPS


    The Phoenix Contact QUINT-UPS Series comprises uninterruptible power supplies (UPS) designed to ensure maximum system availability in industrial applications. These UPS modules feature IQ Technology for intelligent battery management, ensuring reliable power backup during mains failures. Key Features: IQ Technology: Provides real-time monitoring of the energy storage status, including parameters like voltage, current, and temperature, enabling predictive maintenance and optimal battery usage. DIN Rail Mounting: Designed for easy integration into control cabinets with standard DIN rail mounting, facilitating straightforward installation and maintenance. Wide Range of Models: Available in various configurations to meet different power requirements, with input and output voltages typically at 24 V DC and output currents ranging from 5 A to 20 A.
    Technical Specifications

    General

    Note on the battery This product contains a battery with a limited shelf life that must be charged every few months. The product packaging indicates when the battery must be started up or recharged. The general shelf life can be found in the technical data area under “Latest startup”.

    DC operation

    Input Voltage 24 V DC
    Input voltage range 18 V DC ... 30 V DC
    Input voltage range DC 18 V DC ... 30 V DC
    Voltage type of supply voltage DC
    Buffer period 50 min. (1 A)
    Buffer period 5 min. (5 A)
    Current consumption 9.3 A (24 V DC)
    Current consumption 9.7 mA
    Current consumption 1.7 A
    Current consumption 7 A
    Fixed backup threshold ≤ 22.6 V DC

    Output data

    Efficiency > 97.1 % (Mains operation, with charged energy storage)
    Efficiency 97.31 %
    Nominal Output Voltage 24 V DC
    Output voltage range 18 V DC ... 30 V DC
    Nominal output current (IN) 5 A (0 °C ... 40 °C)
    Output current limit > 7.5 A (Battery operation)
    Bridging time 360 s
    Derating 60 °C ... 70 °C (2.5 %/K)
    Output Power 120 W
    Power dissipation 2.5 W (Mains operation)
    Power dissipation 2.7 W (Mains operation)
    Power dissipation 1.9 W (Mains operation)
    Power dissipation 3.3 W (Battery operation)
    Power dissipation 3.3 W (Battery operation)
    Power dissipation 4.1 W (Battery operation)
    Output fuse 1x 15 A
    Connection in parallel 2
    Connection in series No

    Mains operation

    Nominal Output Voltage 24 V DC
    Output voltage range 18 V DC ... 30 V DC (UOUT = UIN - 0,1 V DC)
    Nominal output current (IN) 5 A (0 °C ... 40 °C)
    POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
    Selective Fuse Breaking (ISFB) 30 A (0 °C ... 40 °C)
    Duration 12 ms (SFB technology)

    Battery operation

    Nominal Output Voltage 24 V DC
    Output voltage range 19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
    Nominal output current (IN) 5 A (0 °C ... 40 °C)
    POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
    Selective Fuse Breaking (ISFB) 32.5 A (0 °C ... 40 °C)
    Duration 15 ms (SFB technology)

    Signal: Alarm

    Output description Relay
    Output Voltage ≤ 30 V AC/DC
    Continuous load current ≤ 100 mA

    Signal: Battery charge

    Output description Relay
    Output Voltage ≤ 30 V AC/DC
    Continuous load current ≤ 100 mA

    Signal: Battery mode

    Output description Relay
    Output Voltage ≤ 30 V AC/DC
    Continuous load current ≤ 100 mA

    Signal

    Continuous load current ≤ 200 mA

    Energy storage

    Nominal voltage UN 24 V DC
    End-of-charge voltage 24 V DC ... 29 V DC (temperature compensated)
    Charging current 0.36 A
    Nominal capacity 1.2 Ah
    Buffer period 50 min. (1 A)
    Buffer period 5 min. (5 A)
    Latest startup date (battery only) 3 Months (0 °C ... 20 °C)
    Latest startup date (battery only) 1 Months (30 °C ... 40 °C)
    Latest startup (battery only) - range 1 Months ... 3 Months (20 °C ... 30 °C)
    Battery technology VRLA-AGM
    Memory medium VRLA-AGM Battery 1.2 Ah
    Accumulator type 2x BB Battery BP1.2-12FR (from UPS V/C-level 05)
    IQ Technology Yes
    Temperature sensor yes
    Network management Yes

    Input

    Connection Method Screw connection
    Conductor cross section, rigid min. 0.2 mm²
    Conductor cross section, rigid max. 2.5 mm²
    Conductor cross section flexible min. 0.2 mm²
    Conductor cross section flexible max. 2.5 mm²
    Conductor cross section AWG min. 20
    Conductor cross section AWG max. 12
    Stripping length 7 mm
    Screw thread M4
    Tightening torque, min 0.5 Nm
    Tightening torque max 0.6 Nm

    Output

    Connection Method Screw connection
    Conductor cross section, rigid min. 0.2 mm²
    Conductor cross section, rigid max. 2.5 mm²
    Conductor cross section flexible min. 0.2 mm²
    Conductor cross section flexible max. 2.5 mm²
    Conductor cross section AWG min. 20
    Conductor cross section AWG max. 12
    Stripping length 7 mm
    Screw thread M4
    Tightening torque, min 0.5 Nm
    Tightening torque max 0.6 Nm

    Signal

    Conductor cross section, rigid min. 0.2 mm²
    Conductor cross section, rigid max. 2.5 mm²
    Conductor cross section flexible min. 0.2 mm²
    Conductor cross section flexible max. 2.5 mm²
    Conductor cross section AWG min. 24
    Conductor cross section AWG max. 12
    Screw thread M4
    Tightening torque, min 0.5 Nm
    Tightening torque max 0.6 Nm

    Interfaces

    Interface IFS (Interface system data port)

    Signaling

    Types of signaling LED
    Types of signaling Relay contact
    Types of signaling Interface/software

    Signal output

    Signalization designation Power In OK
    Status display LED
    Note on status display static on
    Note on status display static on

    Signal output: Switching output

    Signalization designation Alarm
    Status display LED
    Note on status display static on
    Color red
    Note on status display static on
    Signalization designation Battery charge
    Status display LED bar graph
    Note on status display dynamic
    Color red/green
    Note on status display dynamic
    Signalization designation Battery mode
    Status display LED
    Note on status display static on
    Color yellow
    Note on status display static on

    Product properties

    Product family QUINT UPS ‒ UPS with integrated battery
    Disposal Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations.
    IQ Technology Yes
    MTBF (IEC 61709, SN 29500) > 806000 h (40 °C)

    Insulation characteristics

    Protection class III
    Degree of pollution 2

    Life expectancy (electrolytic capacitors)

    Time 316800 h

    Dimensions

    Width 88 mm
    Height 138 mm
    Depth 125 mm

    Installation dimensions

    Installation distance right/left 5 mm / 5 mm
    Installation distance top/bottom 50 mm / 50 mm

    Mounting

    Mounting Type DIN rail mounting
    Assembly instructions alignable: horizontal 5 mm, vertical 50 mm
    Mounting Position horizontal DIN rail NS 35, EN 60715

    Material specifications

    Housing Material Metal
    Housing Material Steel sheet, zinc-plated
    Type of housing Steel sheet, zinc-plated
    Side element version Galvanized sheet steel, closed

    Ambient conditions

    Degree of Protection IP20
    Ambient temperature (storage/transport) -20 °C ... 40 °C
    Ambient temperature (charge) 0 °C ... 40 °C
    Ambient temperature (discharge) -20 °C ... 50 °C
    Climatic class 3K3 (in acc. with EN 60721)
    Max. permissible relative humidity (operation) ≤ 95 % (25 °C, non-condensing)
    Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
    Vibration (Operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
    Vibration (Operation) 15 Hz ... 150 Hz, 2.3g tv = 90 min.

    Standards and Regulations

    Rail applications EN 50121-4
    Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
    Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
    Standard - Electrical safety EN 61558-2-17

    Approvals

    UL approvals UL/C-UL Recognized UL 60950-1
    UL approvals UL Listed UL 508

    EMC data

    Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
    EMC requirements for noise emission EN 61000-6-3
    EMC requirements for noise emission EN 61000-6-4
    EMC requirements for noise immunity EN 61000-6-1
    EMC requirements for noise immunity EN 61000-6-2
    Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU

    Electrostatic discharge

    Standards/regulations EN 61000-4-2
    Contact discharge 8 kV (Test Level 4)
    Discharge in air 15 kV (Test Level 4)
    Comments Criterion A

    Electromagnetic HF field

    Standards/regulations EN 61000-4-3
    Frequency Range 80 MHz ... 1 GHz
    Test field strength 20 V/m
    Frequency Range 1 GHz ... 2 GHz
    Test field strength 10 V/m
    Frequency Range 2 GHz ... 3 GHz
    Test field strength 3 V/m
    Comments Criterion A

    Fast transients (burst)

    Standards/regulations EN 61000-4-4
    Input 2 kV (Test Level 3 - asymmetrical)
    Output 2 kV (Test Level 3 - asymmetrical)
    Signal 2 kV (Test Level 4 - asymmetrical)
    Comments Criterion A

    Surge voltage load (surge)

    Standards/regulations EN 61000-4-5
    Input 0.5 kV (Test Level 1 - symmetrical)
    Input 0.5 kV (Test Level 1 - asymmetrical)
    Output 0.5 kV (Test Level 1 - symmetrical)
    Output 0.5 kV (Test Level 1 - asymmetrical)
    Signal 1 kV (Test Level 2 - asymmetrical)
    Comments Criterion B

    Conducted interference

    Standards/regulations EN 61000-4-6
    I/O/S asymmetrical
    Frequency Range 0.15 MHz ... 80 MHz
    Comments Criterion A
    Voltage 10 V (Test Level 3)

    Emitted interference

    Standards/regulations EN 61000-6-3
    Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
    Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential