Products
-
K3MA-J-A2 AC100-240 OMRON
Power supply voltage 100 to 240 VAC 50/60 Hz Allowable power supply voltage range 85 to 110% of the power supply voltage Power consumption 6 VA max. (at maximum load) Input type DC voltage/DC current Output type Judgment output: ContactComparative output: OUT1, OUT2 Current measurement input Measurement range 0-20: 0 to 20 mA4-20: 4 to 20 mA Indication range 0-20: -2.00 to 22.00 mA4-20: 2.00 to 22.00 mA Accuracy ±0.1% FS ±1 digit max. (23±3 ℃) Input impedance Approx. 45 Ω Voltage measurement input Measurement range 0-5: 0 to 5 V1-5: 1 to 5 V5: ±5 V10: ±10 V Indication range 0-5: -0.500 to 5.500 V1-5: 0.500 to 5.500 V5: ±5.500 V10: ±11.000 V Accuracy 0-5: ±0.1% FS ±1 digit max. (23±3 ℃)1-5: ±0.1% FS ±1 digit max. (23±3 ℃)5: ±0.1% FS ±1 digit max. (23±5 ℃)10: ±0.1% FS ±1 digit max. (23±5 ℃) Input impedance 1 MΩ min. Judgment output Contact output 2 output (SPST-NO)Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)Life expectancy: 100,000 operations min. (Electrical)/5,000,000 operations min. (Mechanical) Display Display method Negative LCD (backlit LED) 7-segment digital display Digits 5 digit (-19999 to 99999) Character height 14.2 mm (green/red) A/D conversion method Double integral method Sampling period 250 ms Comparative output response time 750 ms max. Insulation resistance Between the entire external terminal and case: 20 MΩ min. (at 500 VDC)Between inputs, outputs, and power supply: 20 MΩ min. (at 500 VDC) Dielectric strength Between the entire external terminal and case: 2,000 VAC 1 min Noise immunity ±1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 µs/100 ns) Vibration resistance Malfunction: 10 to 55 Hz, Single amplitude 0.35 mm, 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance Malfunction: 100 m/s2, 3 times each in 3 axes 6 directions Degree of protection Front: NEMA TYPE 4X for indoor use (equivalent to IP66)Case rear: IP20Terminals: IP00 + finger protection (VDE0106/100) with terminal Cover Memory protection Non-volatile memory (Number of rewrites: 100,000) Ambient temperature Operating: -10 to 55 ℃ (with no freezing or condensation)Storage: -25 to 65 ℃ (with no freezing or condensation) Ambient humidity Operating: 25 to 85 % (with no condensation) Accessories Waterproof packing, Terminal Cover, Unit label Weight Approx. 200 g
Rs. 14,562.00
-
KCD2-SLD-Ex1.1245
Key Benefits at a Glance 1-channel isolated barrier 24 V DC supply (bus or loop powered) Output 45 mA at 12 V DC Line fault transparency (LFT) Test pulse immunity Housing width 12.5 mm Up to SIL 3 acc. to IEC/EN 61508
Rs. 11,810.00
-
KCD2-SR-Ex2
Key Benefits at a Glance 2-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Housing width 12.5 mm Up to SIL 2 (SC 3) acc. to IEC/EN 61508
Rs. 3,612.00
-
KD-8108 KELTRONIC DYNA LIMIT SWITCH
Brand KELTRONIC DYNA Model No KD-8108 LIMIT SWITCH Stock Ready Stock Delivery All India Delivery Available Dealer Type KELTRONIC DYNA Availability In Stock
Rs. 450.00
-
KD-8108 KELTRONIC DYNA LIMIT SWITCH
Brand KELTRONIC DYNA Model No KD-8108 LIMIT SWITCH Stock Ready Stock Delivery All India Delivery Available Dealer Type KELTRONIC DYNA Availability In Stock
Rs. 450.00
-
Kenstar CHILL HC 40 Personal Air Cooler for Home - Inverter Compatible, Honeycomb Cooling Pads, Collapsible Louvers, (40L, 170 Watts)
Brand Kenstar Mounting Type Freestanding Special Feature Portable, Compact Colour BLACK & WHITE Air Flow Capacity 1300 Cubic Feet Per Minute Controls Type Knob Floor Area 43 Meter Model Name CHILL HC 40 Recommended Uses For Product Residential Included Components COOLER, WHEEL UGB MaterialPlastic Item Weight10700 Grams Form FactorPersonal Wattage150 Watts About this item POWER-PACKED PERFORMANCE: Stay cool with air in every corner covering up to 100 cubic meters (approx. 350 sq. ft.) and superior quality air delivery of 3000 m³/hr and air throw of 10.7 meters (35 ft.). DURABLE COOLING: The air cooler comes with honeycomb cooling pads, which are 3x more durable than conventional pads. They help maximize the airflow and are suitable for high performance water coolers. "GENEROUS COOLING: CHILL 40 is suitable for use in large spaces and outdoor areas. The Kenstar air cooler can effectively cool larger areas and provide comfortable temperatures in an open-air environment. " "SMOOTH EXPERIENCE: The ergonomic design of the control knobs not only makes the device easy to operate, but also enhances its modern and sophisticated aesthetic. Easily move the air cooler with durable castor wheels. Designed for smooth and effortless movement on any surface. " UNINTERRUPTED AIRFLOW: The air cooler is inverter compatible and can keep running even during power cuts or voltage fluctuations, ensuring that you stay cool and comfortable even during the harshest summer days. "SAFE LIVING: Collapsible louvers in this home cooler allow for customizable airflow with easy adjustment, and keep out dust and mosquitoes for a clean and comfortable environment. " SMART HUMIDITY CONTROL: Experience the perfect balance of moisture and create a comfortable environment with precise humidity control technology in the personal desert cooler. Product Description Product information Technical Details Brand Kenstar Mounting Type Freestanding Special Feature Portable, Compact Colour BLACK & WHITE Air Flow Capacity 1300 Cubic Feet Per Minute Controls Type Knob Floor Area 43 Meter Model Name CHILL HC 40 Recommended Uses For Product Residential Included Components COOLER, WHEEL UGB Standby power consumption 140 Watts Number of Speeds 3 Product Dimensions 37D x 46W x 86H Centimeters Voltage 230 Volts Manufacturer Ken Lifestyles Private Limited, Plot No. 254, Phase IV, Udyog Vihar, Gurgaon, Gurgaon, Haryana Manufacturer Ken Lifestyles Private Limited Item model number CHILL HC 40 ASIN B0BP2F6FXZ Additional Information Manufacturer Ken Lifestyles Private Limited, Plot No. 254, Phase IV, Udyog Vihar, Gurgaon, Gurgaon, Haryana Packer Plot No. 254, Phase IV, Udyog Vihar, Gurgaon, Gurgaon, Haryana Item Weight 10 kg 700 g Net Quantity 1 Count Included Components COOLER, WHEEL UGB Generic Name Coolers Best Sellers Rank #52,212 in Home & Kitchen#182 in Portable
Rs. 12,999.00 Rs. 6,400.00
-
Keyence Digital Laser Sensor LV-NH110 LV-NH100 LV-NH300 LV-N10
Specification Download A Munual Model LV-NH110 LV-NH100 LV-NH300 Type Area thrubeam, High power Area thrubeam, High performance FDA (CDRH) Part 1040.10 Class 1 Laser Product IEC 60825-1 Light source Visible red semiconductor laser, Wavelength: 660 nm MEGA 2000 mm 78.74″(Detecting area: 10 mm 0.39″) 2000 mm 78.74″(Detecting area: 30 mm 1.18″) ULTRA SUPER TURBO FINE HSP Ambient temperature -10 to +55 °C 14 to 131 °F (No freezing) Relative humidity 35 to 85 % RH (No condensation) Weight Approx. 75 g Approx. 95 g Model LV-N10 Type Zero line Cable/connector – Main/Expansion unit Expansion unit I/O Control outputs None External input Monitor output Response time 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 Output selection LIGHT-ON/DARK-ON (switch-selectable) Timer function Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,Timer duration selectable: 1 ms to 9,999 ms,Maximum error against the setting value: ±10% max. Control outputs NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less(Multiple connections) 1 output max: 20 mA or less Monitor output – External input Input time 2 ms (ON)/20 ms (OFF) or more*2 Multiple connections toexpansion units Up to 17 units can be connected in total (two-output type is treated as two units) Protection circuit Reverse polarity protection, Over-current protection, Surge absorber Number of interferenceprevention units Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3 Case size H 32.6 mm 1.28″ × W 9.8 mm 0.39″ × L 78.7 mm 3.1″ Rating Power voltage 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5 Powerconsumption Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*6Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*6Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)*7 Environmental resistance Ambient temperature -20 to +55 °C -4 to 131 °F (No freezing)*8 Relative humidity 35 to 85 % RH (No condensation) Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm 0.06″, 2 hours in each of the X, Y, and Z directions Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions Weight Approx. 20 g
Rs. 13,213.00
-
Keyence FU-20
Item specifics Condition New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. See all condition definitionsopens in a new window or tab Brand Keyence MPN Does not apply Manufacturer Part Number Does not apply Type Fiber Optic Sensor Model FU-20 UPC Does not apply
Rs. 1,261.00
-
KFD2-SR2-Ex2.W P&F
Key Benefits at a Glance 2-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL 2 (SC 3) acc. to IEC/EN 61508
Rs. 3,993.00
-
KFU8-DW-1.D P&F
Key Benefits at a Glance Speed monitoring up to 40 kHz 1 pre-select value with relay output and LED indicator 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable Start-up delay Menu driven operation via 4 front keys Period measurement Output signal can be inverted Display devices can be set between 0.1 ... 2.5 sec.
Rs. 24,308.00
-
KFU8-UFC-1.D
Key Benefits at a Glance 1-channel signal conditioner Universal usage at different power supplies Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts Input frequency 1 mHz ... 10 kHz Current output 0/4 mA ... 20 mA Relay contact and transistor output Start-up override Line fault detection (LFD) Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511
Rs. 19,328.00
-
KG5043 IFM
Sensor Type Capacitive Sensor Measurement Range 8 millimeter sensing range Measurement Sensor Type Capacitive Thread Size M18 x 1 Instrument Type Sensor Part Type Transducer Application Modern automation needs, Complex mechanical setups, Diverse machinery installations, Industrial environments Mounting Type Threaded type, Integrated through-holes and recessed grips (for flexible integration) Power Voltage 10-36 VDC Functionality Type Sensor Calibration Achieved through a simple, on-board potentiometer Output Signal PNP electrical design, Normally open output function Wired Connectivity Yes Display Indicator Type Status light Highlighted Features Reverse polarity protection, Clearly visible indication of the switching status via an integrated status light Dimensions M18 x 1 / L = 84 mm, 40 x 26 x 12 millimeters (rectangular housing) Material PVC, Durable PVC cable Weight 124.5 g Shape Rectangular Top Use Cases Monitoring levels, positioning, and flow across diverse machinery installations, Modern automation needs Sustainability Certifications IP67, Protection class II
Rs. 5,425.00