Products Under 5999
-
MODEL - G3R -OA202SZN-MAKE OMRON
• Reduces wiring work by 60% when combined with the P2RF-05-PU Push-In Plus Socket (according to actual OMRON measurements). • These I/O solid state relays can be mounted in OMRON G70A I/O Terminals. • Lineup includes Input Modules for microloads and Output Modules for standard loads. • Certified by UL, CSA, and EN (TÜV certification) (-UTU models) Input Side Model Rated voltage Operatingvoltage Input current Must-operatevoltage Must-releasevoltage G3R-IAZR1SN-UTU 100 to 240 VAC 60 to 264 VAC 15 mA max. 60 VAC max. 20 VAC min. G3R-IDZR1SN-UTU 5 VDC 4 to 6 VDC 8 mA max. 4 VDC max. 1 VDC min. G3R-IDZR1SN-UTU 12 to 24 VDC 6.6 to 32 VDC 6.6 VDC max. 3.6 VDC min. G3R-IDZR1SN-1-UTU 5 VDC 4 to 6 VDC 4 VDC max. 1 VDC min. G3R-IDZR1SN-1-UTU 12 to 24 VDC 6.6 to 32 VDC 6.6 VDC max. 3.6 VDC min. Output Side Model Load voltage Load current G3R-IAZR1SN-UTU 4 to 32 VDC 0.1 to 100 mA G3R-IDZR1SN-UTU G3R-IDZR1SN-UTU G3R-IDZR1SN-1-UTU G3R-IDZR1SN-1-UTU Output Modules for Standard Loads Input Side Model Rated voltage Operatingvoltage Inputcurrent Must-operatevoltage Must-releasevoltage G3R-OA202SZN-UTU 5 to 24 VDC 4 to 32 VDC 15 mA max.(at 25°C) 4 VDC max. 1 VDC min. G3R-OA202SLN-UTU G3R-ODX02SN-UTU 8mA max. G3R-OD201SN-UTU Output Side Model Load voltage Load current *1 Surge withstand current G3R-OA202SZN-UTU 75 to 264 VAC 0.05 to 2 A *2 30 A (60 Hz, 1 cycle) G3R-OA202SLN-UTU G3R-ODX02SN-UTU 4 to 60 VDC 0.01 to 2 A *2 8 A (10 ms) G3R-OD201SN-UTU 40 to 200 VDC 0.01 to 1.5 A *2 8 A (10 ms) *1. Depends on the ambient temperature. Refer to the reference data Load Current vs. Ambient Temperature Rating on Data Sheet for details.*2. The minimum current value is for a temperature of 10°C or higher. I/O External Display Lineup includes Input Modules and Output Modules.The I/O Module classification and AC/DC classification are also indicated in the markings on top of the Relay. Marking Specifications AC IN Input Modules for Microloads, AC input DC IN Input Modules for Microloads, DC input AC OUT Output Modules for Standard Loads, AC output DC OUT Output Modules for Standard Loads, DC output Characteristics Input Modules for Microloads Model G3R-IAZR1SN-UTU G3R-IDZR1SN-UTU G3R-IDZR1SN-1-UTU Operation time 20 ms max. 0.1 ms max. 15 ms max. Release time Response frequency 10 Hz 1 kHz 10 Hz Output ON voltage drop 1.6 V max. Leakage current 5 μA max. Insulation resistance 100 MΩ min. between I/O Dielectric strength 4,000 VAC for 1 min. between I/O Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance 1,000 m/s2 Storage temperature -30 to 100°C (with no icing) Ambient operating temperature -30 to 80°C (with no icing) Ambient operating humidity 45% to 85% Weight Approx. 18 g MTTFd (Reference value) 1,000 years min. Output Modules for Standard Loads Model G3R-OA202SZN-UTU G3R-OA202SLN-UTU G3R-ODX02SN-UTU G3R-OD201SN-UTU Operation time 1/2 load power supplycycle + 1 ms max. 1 ms max. Release time 1/2 load power supply cycle + 1 ms max. 2 ms max. Response frequency 20 Hz 100 Hz Output ON voltage drop 1.6 V max. 2.5 V max. Leakage current 1.5 mA max. 1 mA max. Insulation resistance 100 MΩ min. between I/O Dielectric strength 4,000 VAC for 1 min. between I/O Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance 1,000 m/s2 Storage temperature -30 to 100°C (with no icing) Ambient operatingtemperature -30 to 80°C (with no icing) Ambient operatinghumidity 45% to 85% Weight Approx. 18 g MTTFd (Reference value) 1,000 years min. Accessories (Order Separately) Socket Characteristics Model Ratedcarrycurrent Dielectric strength nsulationresistance * Remarks P2RF-05-PU 10 A Between contact terminals of same polarity: 1,000 VAC for1 min 1,000 MΩ min. Between coil and contact terminals: 4,000 VAC for 1 min P2RFZ-05(-E) 10 A Between contact terminals of same polarity: 1,000 VAC for1 min 1,000 MΩ min. Between coil and contact terminals: 4,000 VAC for 1 min P2R-05P 10 A Between contact terminals of same polarity: 1,000 VAC for1 min 1,000 MΩ min. Between coil and contact terminals: 4,000 VAC for 1 min P2R-057P 10 A Between contact terminals of same polarity: 1,000 VAC for1 min 1,000 MΩ min. Between coil and contact terminals: 5,000 VAC for 1 min P2R-05A 10 A Between contact terminals of same polarity: 1,000 VAC for1 min 1,000 MΩ min. Between ground terminals: 1,500 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min
Rs. 1,059.00
-
SMPS 50W,DC12V,4.2A,AC100-240V, Model S8FS-C05012J
DELIVERY PERIOD : 1-2 WEEKS Usage/Application Industrial Automation Brand OMRON Output Voltage 12V Input Voltage 115V Design Smps Switch mode power supply - OMRON (S8FS-C) - Output 12V / (Output) 4.2A / 50W - with Overload protection + Automatic reset - input (input 115Vac) 0.97A / (input 230Vac) 0.59A
Rs. 3,683.00 Rs. 2,140.52
-
SMPS 50W,DC5V,10A,AC100-240V, Model S8FS-C05005J
DELIVERY PERIOD : 1-2 WEEKS Omron S8FS-C05005J Power Supply,Covered type,100 to 240 VAC, Power rating 50W, Output: 5VDC, 10A Terminal block facing forward (Screw terminal), Harmonic current emissions,Omron Smps,Industrial use for switch mode Power Supply Omron,Din Rail Power Suply Omron, Power rating Item Output voltage 50 W 5 V 12 V 15 V 24 V 48 V Efficiency * 115 VAC input 79% typ. 83% typ. 84% typ. 86% typ. 87% typ. 230 VAC input 80% typ. 84% typ. 85% typ. 86% typ. 87% typ. Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 0.97 A typ. 230 VAC input 0.59 A typ. Power factor --- Leakage current 115 VAC input 0.25 mA 0.25 mA 0.25 mA 0.25 mA 0.25 mA 230 VAC input 0.60 mA 0.55 mA 0.55 mA 0.55 mA 0.55 mA Inrush current * (for a cold start at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 10 A 4.2 A 3.4 A 2.2 A 1.1 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 240 VAC input 80 mVp-p max. 110 mVp-p max. 100 mVp-p max. 100 mVp-p max. 120 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperature vari- ation influence 100 to 240 VAC input 0.03%/°C max. Startup time * 115 VAC input 730 ms typ. 730 ms typ. 710 ms typ. 710 ms typ. 770 ms typ. 230 VAC input 680 ms typ. 670 ms typ. 610 ms typ. 640 ms typ. 690 ms typ. Hold time * 115 VAC input 12 ms typ. 14 ms typ. 14 ms typ. 14 ms typ. 14 ms typ. 230 VAC input 71 ms typ. 77 ms typ. 78 ms typ. 77 ms typ. 80 ms typ. Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MÙ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature -20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W´H´D) Refer to Dimensions on pages 20 and 24. Weight 300 g max. Cooling fan No Degree of protection --- Stan- dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 60950-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No60950-1 CCC: GB4943 Conformed Standards EN: EN 60950-1 OVC II Pol2 Marine Standards No SEMI No
Rs. 3,832.00 Rs. 2,260.88
-
POWER SUPPLY S8FS-C05012J (SMPS 50W) MAKE:OMRON, O/P 12V DC, 4.2 A, I/P 100 to 240 VA
DELIVERY PERIOD : 1-2 WEEKS Brand Omron Output Voltage 12V dc Output Current 4.2A Power Rating 50W Number of Outputs 1 Input Voltage 100 → 240V ac Series S8FS-C
Rs. 3,683.00 Rs. 2,141.11
-
SMPS S8FS-C03524J, 1.5 AMP I/P- 220VAC, O/P 24VDC 35W MAKE-OMRON
DELIVERY PERIOD : 1-2 WEEKS Type Enclosed Mounting method Direct mounting Phase Single Power output 35 W Efficiency 87 % Output voltage 24 V Rated output current 1.5 A Temperature range -20-60 °C Features Terminal block facing forward Terminal type Screw Communication port(s) None Alarm function - Number of output branches 1 Rated supply voltage at AC 50 Hz 100-240 V Allowable supply voltage AC 85-264 V Allowable supply voltage DC 120-370 V Product Width (unpacked) 97 mm Product Height (unpacked) 36 mm Product Depth (unpacked) 99 mm
Rs. 3,036.00 Rs. 1,791.24
-
SMPS S8FS-C01524J, 0.7 AMP I/P- 220VAC, O/P 24VDC 15W MAKE-OMRON
DELIVERY PERIOD : 1-2 WEEKS Technical Specifications of Omron Power Supply 15 W 24V S8FS-C01524J: Type: Metal framePower: 15WOutput: 24V, 0.7AInput: 100-240V AC or 120-370V DCEfficiency: 87%Temperature range: -20 to 60℃Compact designUpward-facing terminal.
Rs. 2,439.00 Rs. 1,439.00
-
POWER SUPPLY S8VK-C06024, 2.5 AMP OMRON I/P- 220VAC, O/P 24VDC, 60W
DELIVERY PERIOD : 1-2 WEEKS Type Book type Mounting method DIN rail Phase Single Power output 60 W Efficiency 88 % Output voltage 24 V Rated output current 2.5 A Power boost ratio 120 % Temperature range -40-70 °C Terminal Screw Communication port(s) None Alarm function - Number of output branches 1 Rated supply voltage at AC 50 Hz 100-240 V Allowable supply voltage AC 85-264 V Allowable supply voltage DC 90-350 V Width 32 mm Height 90 mm Depth 110 mm
Rs. 4,798.00 Rs. 2,830.82
-
RELAY SLIM G2RV-1-S DC21 OMRON MAKE
DELIVERY PERIOD : 1-2 WEEKS Product Attribute Attribute Value Select Attribute Manufacturer: Omron Product Category: Industrial Relays Delivery Restrictions: Mouser does not sell this product in your region. RoHS: Details Mounting Style: Through Hole Product: Relays Type: Slim Contact Termination: Plug In Relay Contact Form: 1 Form C (SPDT-NO, NC) Contact Current Rating: 6 A Coil Termination: Plug In Coil Type: Non-Latching Coil Voltage: 24 VDC Coil Current: 13.5 mA Switching Voltage: 400 VAC, 125 VDC Contact Material: Silver (Ag) Series: G2RV Length: 30.5 mm Width: 5.2 mm Height: 33 mm Brand: Omron Automation and Safety Contact Form: SPDT (1 Form C) Power Consumption: 300 mW Product Type: Industrial Relays Factory Pack Quantity: 1 Subcategory: Relays Part # Aliases: 1278668 G2RV1SDC21 Unit Weight: 17 g
Rs. 318.01
-
RELAY BASE,MODEL-P2RFZ-05-E OMRON MAKE
DELIVERY PERIOD : 1-2 WEEKS Product Attribute Attribute Value Select Attribute Manufacturer: Omron Product Category: Relay Sockets & Fixings RoHS: Details Product: Relay Sockets Associated Relay Series: G2R-1-S (S) Termination Style: Screw Brand: Omron Automation and Safety Mounting Style: PCB Mount Product Type: Relay Sockets & Hardware Series: G2R Factory Pack Quantity: 1 Subcategory: Relays Part # Aliases: P2RFZ05E
Rs. 456.00 Rs. 269.04
-
RELAY G7SA-2A2B DC24 OMRON
DELIVERY PERIOD : 1-2 WEEKS Product Attribute Attribute Value Select Attribute Manufacturer: Omron Product Category: Safety Relays RoHS: Details Coil Voltage: 24 VDC Relay Contact Form: 2 Form A (DPST-NO) Contact Termination: Solder Pin Contact Rating: 6 A Brand: Omron Automation and Safety Coil Resistance: 1.6 kOhms Contact Form: DPST (2 Form A) Current Rating - Max: 6 A Product: Safety Relays Product Type: Safety Relays Factory Pack Quantity: 1 Subcategory: Relays Part # Aliases: 376123 G7SA2A2B24DC 1221753 G7SA2A2BDC24 Unit Weight: 22 g
Rs. 3,168.00 Rs. 1,869.12
-
MICRO SENSOR, EE-SPX403N, MAKE- OMRON LIGHT-ON, THROUGH BEAM TYPE, NPN, 24VDC
DELIVERY PERIOD : 1-2 WEEKS Technical Specifications Sensing Method Through Beam Supply Voltage Min 12VDC Supply Voltage Max 24VDC Sensor Case / Package Module Collector Current IC Max - IP Rating IP50 Operating Temperature Min -10°C Product Range - Sensing Distance / Slot Width 13mm Supply Voltage DC Min 12V Output Current 80mA Collector Emitter Voltage Max - Sensor Output Type NPN Open Collector Sensor Mounting Through Hole Operating Temperature Max 55°C Qualification
Rs. 3,994.00 Rs. 2,356.00
-
RELAY OMRON MY2N 24VAC MY2N 24VAC WITH INDICATOR MAKE-OMRON
DELIVERY PERIOD : 1-2 WEEKS Technical Details Connector Type Screw Contact Material Silver Tin Oxide Contact Type 2NO Mounting Type In Top Brand OMRON RELAY Operation Mode Mechanical Coil Voltage 24 Volts Contact Current Rating 5 Amps Maximum Switching Voltage 24 Volts Specification Met RoHS Manufacturer OMRON Model number MY2N-GS DC24 Item Weight 99.8 g Product Dimensions 10 x 10 x 10 cm; 99.79 g Item model number MY2N-GS DC24 Item Height 10 Centimeters Item Width 10 Centimeters Voltage 24 Volts (DC) Are batteries included? No
Rs. 334.00 Rs. 197.06