Products Under 5999
-
POWER SUPPLY S8FS-C10024 OMRON OMRON MAKE
DELIVERY PERIOD : 1-2 WEEKS Type Enclosed Mounting method Direct mounting Phase Single Power output 100 W Efficiency 87 % Output voltage 24 V Rated output current 4.5 A Temperature range -20-60 °C Features Terminal block facing upward Terminal type Screw Communication port(s) None Alarm function - Number of output branches 1 Rated supply voltage at AC 50 Hz 100-240 V Allowable supply voltage AC 85-264 V Allowable supply voltage DC 248-373 V Product Width (unpacked) 97 mm Product Height (unpacked) 38 mm Product Depth (unpacked) 159 mm
Rs. 3,933.00 Rs. 2,355.28
-
POWER SUPPLY S8FS-G15024CD 6.5 AMP OMRON I/P- 220VAC, O/P 24VDC,DIN MOUNTING
DELIVERY PERIOD : 1-2 WEEKS Power rating 150 W Output voltage 24 VDC Efficiency 87 % typ. (at 100 VAC input)89 % typ. (at 200 VAC input)90 % typ. (at 230 VAC input) Input Rated input voltage 100 to 240 VAC Allowable input voltage variable range 85 to 264 VAC (Single-phase)80 to 370 VDC Frequency 50/60Hz (47 to 450 Hz) Rated input current 3 A typ. (at 100 VAC input)1.8 A typ. (at 200 VAC input) Leakage current 0.5 mA max. (at 100 VAC input)1 mA max. (at 200 VAC input) Inrush current (cold start at 25 ℃) 14 A typ. (at 100 VAC input)28 A typ. (at 200 VAC input) Output Rated output current 6.5 A Output voltage variable range -10 to +15 % (With V.ADJ) Ripple 110 mV(p-p) max. Static input variation influence 0.5 % max. Static load variation influence 1.0 % max. Ambient temperature variation influence 0.05 %/℃ max. Start up time 1000 ms max. (at 100 VAC input)1000 ms max. (at 200 VAC input) Hold time 10 ms typ. (at 100 VAC input)55 ms typ. (at 200 VAC input) Additional functions Overload protection Yes, automatic reset Overvoltage protection Yes, Shut off the input voltage and turn on the input again Overheat protection No Series operation Yes (Up to 2 Power Supplies with external diode) Parallel operation No (However, backup operation is possible, external diodes required.) Output indicator Yes (color: green) Insulation Dielectric strength Between all input terminals and all output terminals: 3 kVAC for 1 min, Cut-off current: 20 mABetween all input terminals and PE terminals: 2 kVAC for 1 min, Cut-off current: 20 mABetween all output terminals and PE terminals: 1 kVAC for 1 min, Cut-off current: 20 mA Insulation resistance Between all output terminals and all input terminals/PE terminals: 100 MΩ min., at 500 VDC Environment Vibration resistance 10 to 55 Hz, 4.5 G max., 0.375 mm single amplitude in each 3 directions for 2 hours Shock resistance 150 m/s2, in each 6 directions 3 times Altitude 3000 m max. Ambient temperature (Operating) -20 to 70 ℃ (with no freezing or condensation) Ambient temperature (Storage) -25 to 75 ℃ (with no freezing or condensation) Ambient humidity (Operating) 90 %RH max. Ambient humidity (Storage) 90 %RH max. Reliability Life expectancy 10 years min. (at rated input, a load rate of 50% load, under the temperature of 40 ℃ max., standard mounting) Construction Construction Covered type Connection Terminal blocks Terminal type Screw terminal Mounting DIN track mounting Cooling fan Cooling fan No Weight (Main) 500 g max. Note Do not use the Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
Rs. 8,732.00 Rs. 5,151.88
-
POWER SUPPLY S8FS-C15024J, 6.5 AMP OMRON I/P- 220VAC, O/P 24VDC,DIN RAIL MOTD.
DELIVERY PERIOD : 1-2 WEEKS Type Enclosed Mounting method Direct mounting Phase Single Power output 150 W Efficiency 87 % Output voltage 24 V Rated output current 6.5 A Temperature range -20-60 °C Features Terminal block facing forward Terminal type Screw Communication port(s) None Alarm function - Number of output branches 1 Rated supply voltage at AC 50 Hz 100-240 V Allowable supply voltage AC 90-264 V Allowable supply voltage DC 254-373 V Product Width (unpacked) 97 mm Product Height (unpacked) 38 mm Product Depth (unpacked) 199 mm
Rs. 5,125.00 Rs. 3,023.75
-
SWITCH LIMIT-OMRON TYPE-WLCA2-7
DELIVERY PERIOD : 1-2 WEEKS Product Attribute Attribute Value Select Attribute Manufacturer: Omron Product Category: Limit Switches Brand: Omron Automation and Safety Product Type: Limit Switches Factory Pack Quantity: 1 Subcategory: Switches Part # Aliases: WLCA27N
Rs. 5,819.00 Rs. 3,433.21
-
PHOTO SENSOR E3FA-DP12 2M OMRON MAKE
DELIVERY PERIOD : 1-2 WEEKS Photoelectric Sensors Image Photoelectric Sensor, Diffuse-reflective, Sensing distance: 300 mm, PNP output, Pre-wired, 2 m Sensing method Diffuse-reflective Sensing distance White paper 300 x 300 mm: 300 mm Light source Red LED (624 nm) Connection method Pre-wired models
Rs. 4,912.00 Rs. 2,898.08
-
SMPS BRACKET S82Y-FSC015DIN OMRON OMRON
DELIVERY PERIOD : 1-2 WEEKS Brand APC Voltage 24 V Output Power 25W Current 25A Output Voltage 5 V DC Usage/Application Industrial Automation Output Type Triple, Dual, Single Din mounting Bracket for S8FS-SERIES 15W
Rs. 445.00 Rs. 262.55
-
SMPS S8FS-C01505J OMRON OMRON
DELIVERY PERIOD : 1-2 WEEKS Ratings, Characteristics, and Functions Power rating 15 W Output voltage (VDC) 5 V 12 V 15 V 24 V Efficiency * 115 VAC input 80% typ. 84% typ. 84% typ. 85% typ. 230 VAC input 82% typ. 85% typ. 86% typ. 87% typ. Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DCinput is the positive side and safety standards do not apply.) (Derating isrequired according to the input voltage. Refer to Derating Curves onData Sheet.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 0.3 A typ. 230 VAC input 0.19 A typ. Power factor -- Leakagecurrent 115 VAC input 0.05 mA 0.05 mA 0.05 mA 0.05 mA 230 VAC input 0.10 mA 0.10 mA 0.10 mA 0.10 mA Inrushcurrent *(for a coldstart at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 3 A 1.3 A 1 A 0.7 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noisevoltage * 100 to 240VAC input 30 mVp-p max. 30 mVp-p max. 40 mVp-p max. 30 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperaturevariationinfluence 100 to 240VAC input 0.03%/°C max. Startuptime * 115 VAC input 490 ms typ. 500 ms typ. 470 ms typ. 480 ms typ. 230 VAC input 470 ms typ. 480 ms typ. 450 ms typ. 460 ms typ. Hold time * 115 VAC input 14 ms typ. 16 ms typ. 18 ms typ. 15 ms typ. 230 VAC input 83 ms typ. 87 ms typ. 92 ms typ. 79 ms typ. Addi-tionalfunc-tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off theinput voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula-tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) currentcutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) currentcutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PEterminals) at 500 VDC Envi-ron-ment Ambient operating temperature -20 to 60°C (Derating is required according to the temperature. Referto Derating Curves on Data Sheet.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Zdirections10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Zdirections Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Relia-bility MTBF 135,000 hrs min. Life expectancy * 10 years min. Con-struc-tion Dimensions (W × H × D) Refer to Dimensions. Weight 150 g max. Cooling fan No Degree of protection -- Stan-dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI ConductedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 RadiatedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved StandardsUL: cURus UL 62368-1 (Recognition) OVC II Pol2CSA: cURus C22.2 No62368-1CCC: GB4943Conformed StandardsEN: EN 62368-1 OVC II Pol2RCM (EN61000-6-4)BIS: IS 13252 (Part1) (5 V, 24 V only) * Marine Standards No SEMI No * Refer to Conditions of below. Power rating 25 W Output voltage (VDC) 5 V 12 V 15 V 24 V Efficiency * 115 VAC input 80% typ. 84% typ. 85% typ. 86% typ. 230 VAC input 82% typ. 86% typ. 88% typ. 88% typ. Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DCinput is the positive side and safety standards do not apply.) (Derating isrequired according to the input voltage. Refer to Derating Curves onData Sheet.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 0.49 A typ. 230 VAC input 0.3 A typ. Power factor -- Leakagecurrent 115 VAC input 0.10 mA 0.10 mA 0.10 mA 0.10 mA 230 VAC input 0.20 mA 0.20 mA 0.20 mA 0.20 mA Inrushcurrent *(for a coldstart at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 5 A 2.1 A 1.7 A 1.1 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noisevoltage * 100 to 240VAC input 20 mVp-p max. 20 mVp-p max. 30 mVp-p max. 40 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperaturevariationinfluence 100 to 240VAC input 0.03%/°C max. Startuptime * 115 VAC input 390 ms typ. 340 ms typ. 400 ms typ. 360 ms typ. 230 VAC input 360 ms typ. 350 ms typ. 400 ms typ. 360 ms typ. Hold time * 115 VAC input 17 ms typ. 22 ms typ. 23 ms typ. 21 ms typ. 230 VAC input 103 ms typ. 113 ms typ. 117 ms typ. 112 ms typ. Addi-tionalfunc-tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off theinput voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula-tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) currentcutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) currentcutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PEterminals) at 500 VDC Envi-ron-ment Ambient operating temperature -20 to 60°C (Derating is required according to the temperature. Referto Derating Curves on Data Sheet.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Zdirections10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Zdirections Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Relia-bility MTBF 135,000 hrs min. Life expectancy * 10 years min. Con-struc-tion Dimensions (W × H × D) Refer to Dimensions. Weight 250 g max. Cooling fan No Degree of protection -- Stan-dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI ConductedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 RadiatedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved StandardsUL: cURus UL 62368-1 (Recognition) OVC II Pol2CSA: cURus C22.2 No62368-1CCC: GB4943Conformed StandardsEN: EN 62368-1 OVC II Pol2RCM (EN61000-6-4)BIS: IS 13252 (Part1) (5 V, 24 V only) * Marine Standards No SEMI No * Refer to Conditions of below. Power rating 35 W Output voltage (VDC) 5 V 12 V 15 V 24 V Efficiency * 115 VAC input 81% typ. 83% typ. 84% typ. 87% typ. 230 VAC input 81% typ. 84% typ. 84% typ. 87% typ. Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DCinput is the positive side and safety standards do not apply.) (Derating isrequired according to the input voltage. Refer to Derating Curves onData Sheet.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 0.66 A typ. 230 VAC input 0.41 A typ. Power factor -- Leakagecurrent 115 VAC input 0.15 mA 0.15 mA 0.15 mA 0.15 mA 230 VAC input 0.30 mA 0.25 mA 0.25 mA 0.25 mA Inrushcurrent *(for a coldstart at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 7 A 3 A 2.4 A 1.5 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noisevoltage * 100 to 240VAC input 80 mVp-p max. 90 mVp-p max. 90 mVp-p max. 80 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperaturevariationinfluence 100 to 240VAC input 0.03%/°C max. Startuptime * 115 VAC input 750 ms typ. 750 ms typ. 760 ms typ. 770 ms typ. 230 VAC input 700 ms typ. 690 ms typ. 710 ms typ. 720 ms typ. Hold time * 115 VAC input 13 ms typ. 14 ms typ. 14 ms typ. 15 ms typ. 230 VAC input 74 ms typ. 75 ms typ. 75 ms typ. 79 ms typ. Addi-tionalfunc-tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off theinput voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula-tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) currentcutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) currentcutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PEterminals) at 500 VDC Envi-ron-ment Ambient operating temperature -20 to 60°C (Derating is required according to the temperature. Referto Derating Curves on Data Sheet.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Zdirections10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Zdirections Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Relia-bility MTBF 135,000 hrs min. Life expectancy * 10 years min. Con-struc-tion Dimensions (W × H × D) Refer to Dimensions. Weight 250 g max. Cooling fan No Degree of protection -- Stan-dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI ConductedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 RadiatedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved StandardsUL: cURus UL 62368-1 (Recognition) OVC II Pol2CSA: cURus C22.2 No62368-1CCC: GB4943Conformed StandardsEN: EN 62368-1 OVC II Pol2RCM (EN61000-6-4)BIS: IS 13252 (Part1) (24 V only) * Marine Standards No SEMI No * Refer to Conditions of below. Power rating 50 W Output voltage (VDC) 5 V 12 V 15 V 24 V 48 V Efficiency * 115 VAC input 79% typ. 83% typ. 84% typ. 86% typ. 87% typ. 230 VAC input 80% typ. 84% typ. 85% typ. 86% typ. 87% typ. Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DCinput is the positive side and safety standards do not apply.) (Derating isrequired according to the input voltage. Refer to Derating Curves onData Sheet.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 0.97 A typ. 230 VAC input 0.59 A typ. Power factor -- Leakagecurrent 115 VAC input 0.25 mA 0.25 mA 0.25 mA 0.25 mA 0.25 mA 230 VAC input 0.60 mA 0.55 mA 0.55 mA 0.55 mA 0.55 mA Inrushcurrent *(for a coldstart at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 10 A 4.2 A 3.4 A 2.2 A 1.1 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noisevoltage * 100 to 240VAC input 80 mVp-pmax. 110 mVp-pmax. 100 mVp-pmax. 100 mVp-pmax. 120 mVp-pmax. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperaturevariationinfluence 100 to 240VAC input 0.03%/°C max. Startuptime * 115 VAC input 730 ms typ. 730 ms typ. 710 ms typ. 710 ms typ. 770 ms typ. 230 VAC input 680 ms typ. 670 ms typ. 610 ms typ. 640 ms typ. 690 ms typ. Hold time * 115 VAC input 12 ms typ. 14 ms typ. 14 ms typ. 14 ms typ. 14 ms typ. 230 VAC input 71 ms typ. 77 ms typ. 78 ms typ. 77 ms typ. 80 ms typ. Addi-tionalfunc-tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off theinput voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula-tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) currentcutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) currentcutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PEterminals) at 500 VDC Envi-ron-ment Ambient operating temperature -20 to 60°C (Derating is required according to the temperature. Referto Derating Curves on Data Sheet.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Zdirections10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Zdirections Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Relia-bility MTBF 135,000 hrs min. Life expectancy * 10 years min. Con-struc-tion Dimensions (W × H × D) Refer to Dimensions. Weight 300 g max. Cooling fan No Degree of protection -- Stan-dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI ConductedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 RadiatedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved StandardsUL: cURus UL 62368-1 (Recognition) OVC II Pol2CSA: cURus C22.2 No62368-1CCC: GB4943Conformed StandardsEN: EN 62368-1 OVC II Pol2RCM (EN61000-6-4)BIS: IS 13252 (Part1) (5 V, 12 V, 24 V only) * Marine Standards No SEMI No * Refer to Conditions of below. Power rating 75 W Output voltage (VDC) 5 V 12 V 15 V 24 V 48 V Efficiency * 115 VAC input 75% typ. 83% typ. 84% typ. 87% typ. 87% typ. 230 VAC input 77% typ. 83% typ. 84% typ. 87% typ. 87% typ. Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DCinput is the positive side and safety standards do not apply.) (Derating isrequired according to the input voltage. Refer to Derating Curves onData Sheet.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 1.4 A typ. 230 VAC input 0.83 A typ. Power factor -- Leakagecurrent 115 VAC input 0.25 mA 0.25 mA 0.25 mA 0.25 mA 0.25 mA 230 VAC input 0.60 mA 0.60 mA 0.60 mA 0.60 mA 0.60 mA Inrushcurrent *(for a coldstart at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 14 A 6.2 A 5 A 3.2 A 1.6 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noisevoltage * 100 to 240VAC input 80 mVp-pmax. 110 mVp-pmax. 90 mVp-pmax. 110 mVp-pmax. 140 mVp-pmax. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperaturevariationinfluence 100 to 240VAC input 0.03%/°C max. Startuptime * 115 VAC input 750 ms typ. 720 ms typ. 730 ms typ. 750 ms typ. 700 ms typ. 230 VAC input 710 ms typ. 680 ms typ. 690 ms typ. 690 ms typ. 730 ms typ. Hold time * 115 VAC input 12 ms typ. 13 ms typ. 13 ms typ. 14 ms typ. 15 ms typ. 230 VAC input 75 ms typ. 74 ms typ. 74 ms typ. 76 ms typ. 78 ms typ. Addi-tionalfunc-tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off theinput voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula-tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) currentcutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) currentcutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PEterminals) at 500 VDC Envi-ron-ment Ambient operating temperature -20 to 60°C (Derating is required according to the temperature. Referto Derating Curves on Data Sheet.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Zdirections10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Zdirections Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Relia-bility MTBF 135,000 hrs min. Life expectancy * 10 years min. Con-struc-tion Dimensions (W × H × D) Refer to Dimensions. Weight 350 g max. Cooling fan No Degree of protection -- Stan-dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI ConductedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 RadiatedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved StandardsUL: cURus UL 62368-1 (Recognition) OVC II Pol2CSA: cURus C22.2 No62368-1CCC: GB4943Conformed StandardsEN: EN 62368-1 OVC II Pol2RCM (EN61000-6-4)BIS: IS 13252 (Part1) (24 V, 48 V only) * Marine Standards No SEMI No * Refer to Conditions of below. Power rating 100 W Output voltage (VDC) 5 V 12 V 15 V 24 V 36 V 48 V Efficiency * 115 VAC input 80% typ. 82% typ. 83% typ. 85% typ. 86% typ. 87% typ. 230 VAC input 81% typ. 83% typ. 84% typ. 87% typ. 87% typ. 88% typ. Input Voltage range * Single phase 85 to 132 VAC, 176 to 264 VAC, 248 to 373 VDC Selectwith the switch. (The L terminal for the DC input is the positive side andsafety standards do not apply.) (Derating is required according to the inputvoltage. Refer to Derating Curves on Data Sheet.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 2 A typ. 230 VAC input 1.1 A typ. Power factor -- Leakagecurrent 115 VAC input 0.35 mA 0.35 mA 0.35 mA 0.35 mA 0.40 mA 0.40 mA 230 VAC input 0.60 mA 0.55 mA 0.60 mA 0.50 mA 0.60 mA 0.60 mA Inrushcurrent *(for a coldstart at 25°) 115 VAC input 32 A typ. 230 VAC input 32 A typ. Output Rated Output Current 20 A 8.5 A 7 A 4.5 A 2.8 A 2.3 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noisevoltage * 100 to 120VAC/200 to240 VAC input 70 mVp-pmax. 100 mVp-pmax. 70 mVp-pmax. 120 mVp-pmax. 90 mVp-pmax. 120 mVp-pmax. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperaturevariationinfluence 100 to 120VAC/200 to240 VAC input 0.03%/°C max. Startuptime * 115 VAC input 710 ms typ. 440 ms typ. 440 ms typ. 430 ms typ. 450 ms typ. 430 ms typ. 230 VAC input 720 ms typ. 700 ms typ. 720 ms typ. 660 ms typ. 690 ms typ. 660 ms typ. Hold time * 115 VAC input 23 ms typ. 37 ms typ. 36 ms typ. 34 ms typ. 36 ms typ. 34 ms typ. 230 VAC input 29 ms typ. 40 ms typ. 39 ms typ. 39 ms typ. 41 ms typ. 38 ms typ. Addi-tionalfunc-tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off theinput voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula-tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) currentcutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) currentcutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PEterminals) at 500 VDC Envi-ron-ment Ambient operating temperature -20 to 60°C (Derating is required according to the temperature. Referto Derating Curves on Data Sheet.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Zdirections10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Zdirections Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Relia-bility MTBF 135,000 hrs min. Life expectancy * 10 years min. Con-struc-tion Dimensions (W × H × D) Refer to Dimensions. Weight 400 g max. Cooling fan No Degree of protection -- Stan-dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI ConductedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 RadiatedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved StandardsUL: cURus UL 62368-1 (Recognition) OVC II Pol2CSA: cURus C22.2 No62368-1CCC: GB4943Conformed StandardsEN: EN 62368-1 OVC II Pol2RCM (EN61000-6-4)BIS: IS 13252 (Part1) (24 V, 48 V only) * Marine Standards No SEMI No * Refer to Conditions of below. Power rating 150 W Output voltage (VDC) 5 V 12 V 15 V 24 V 36 V 48 V Efficiency * 115 VAC input 81% typ. 84% typ. 85% typ. 86% typ. 86% typ. 87% typ. 230 VAC input 82% typ. 85% typ. 86% typ. 87% typ. 87% typ. 88% typ. Input Voltage range * Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373VDC Select with the switch. (The L terminal for the DC input is thepositive side and safety standards do not apply.) (Derating is requiredaccording to the input voltage. Refer to Derating Curves on Data Sheet.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 2.8 A typ. 230 VAC input 1.6 A typ. Power factor -- Leakagecurrent 115 VAC input 0.50 mA 0.50 mA 0.50 mA 0.50 mA 0.40 mA 0.50 mA 230 VAC input 0.75 mA 0.75 mA 0.75 mA 0.70 mA 0.60 mA 0.70 mA Inrushcurrent *(for a coldstart at 25°) 115 VAC input 32 A typ. 230 VAC input 32 A typ. Output Rated Output Current 26 A 12.5 A 10 A 6.5 A 4.3 A 3.3 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noisevoltage * 100 to 120VAC/200 to240 VAC input 50 mVp-pmax. 90 mVp-pmax. 110 mVp-pmax. 100 mVp-pmax. 200 mVp-pmax. 120 mVp-pmax. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperaturevariationinfluence 100 to 120VAC/200 to240 VAC input 0.03%/°C max. Startuptime * 115 VAC input 770 ms typ. 730 ms typ. 740 ms typ. 770 ms typ. 730 ms typ. 760 ms typ. 230 VAC input 750 ms typ. 720 ms typ. 730 ms typ. 760 ms typ. 720 ms typ. 750 ms typ. Hold time * 115 VAC input 29 ms typ. 24 ms typ. 27 ms typ. 23 ms typ. 23 ms typ. 21 ms typ. 230 VAC input 35 ms typ. 30 ms typ. 31 ms typ. 28 ms typ. 29 ms typ. 27 ms typ. Addi-tionalfunc-tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off theinput voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula-tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) currentcutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) currentcutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PEterminals) at 500 VDC Envi-ron-ment Ambient operating temperature -20 to 60°C (Derating is required according to the temperature. Referto Derating Curves on Data Sheet.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Zdirections10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Zdirections Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Relia-bility MTBF 135,000 hrs min. Life expectancy * 10 years min. Con-struc-tion Dimensions (W × H × D) Refer to Dimensions. Weight 500 g max. Cooling fan No Degree of protection -- Stan-dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI ConductedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 RadiatedEmissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved StandardsUL: cURus UL 62368-1 (Recognition) OVC II Pol2CSA: cURus C22.2 No62368-1CCC: GB4943Conformed StandardsEN: EN 62368-1 OVC II Pol2RCM (EN61000-6-4)BIS: IS 13252 (Part1) (12 V, 24 V only) * Marine Standards No SEMI No * Refer to Conditions of below. Power rating 200 W Output voltage (VDC) 5 V 12 V 24 V 36 V 48 V Efficiency * 115 VAC input 81% typ. 85% typ. 88% typ. 89% typ. 88% typ. 230 VAC input 81% typ. 87% typ. 88% typ. 90% typ. 90% typ. Input Voltage range * Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373VDC Select with the switch. (The L terminal for the DC input is thepositive side and safety standards do not apply.) (Derating is requiredaccording to the input voltage. Refer to Derating Curves on Data Sheet.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 4 A typ. 230 VAC input 2.3 A typ. Power factor -- Leakagecurrent 115 VAC input 0.35 mA 0.25 mA 0.40 mA 0.20 mA 0.40 mA 230 VAC input 0.60 mA 0.50 mA 0.75 mA 0.45 mA 0.80 mA Inrushcurrent *(for a coldstart at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 40 A 17 A 8.8 A 5.9 A 4.43 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noisevoltage * 100 to 120VAC/200 to240 VAC input 60 mVp-pmax. 60 mVp-pmax. 110 mVp-pmax. 130 mVp-pmax. 120 mVp-pmax. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperaturevariationinfluence 100 to 120VAC/200 to240 VAC input 0.03%/°C max. Startuptime * 115 VAC input 620 ms typ. 630 ms typ. 580 ms typ. 630 ms typ. 620 ms typ. 230 VAC input 600 ms typ. 610 ms typ. 550 ms typ. 600 ms typ. 600 ms typ. Hold time * 115 VAC input 32 ms typ. 30 ms typ. 38 ms typ. 30 ms typ. 31 ms typ. 230 VAC input 37 ms typ. 35 ms typ. 45 ms typ. 37 ms typ. 37 ms typ. Addi-tionalfunc-tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off theinput voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula-tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) currentcutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) currentcutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PEterminals) at 500 VDC Envi-ron-ment Ambient operating temperature -20 to 50°C (Derating is required according to the temperature. Referto Derating Curves on Data Sheet.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Zdirections10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Zdirections Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Relia-bility MTBF 135,000 hrs min. Life expectancy * 10 years min. Con-struc-tion Dimensions (W × H × D) Refer to Dimensions. Weight 700 g max. Cooling fan No Degree of protection -- Stan-dards Harmonic current emissions -- EMI ConductedEmissions Conforms to EN 61204-3 Class A, EN 55011 Class A RadiatedEmissions Conforms to EN 61204-3 Class A, EN 55011 Class A EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved StandardsUL: cURus UL 62368-1 (Recognition) OVC II Pol2CSA: cURus C22.2 No62368-1Conformed StandardsEN: EN 62368-1 OVC II Pol2RCM (EN61000-6-4)BIS: IS 13252 (Part1) (24 V only) * Marine Standards No SEMI No * Refer to Conditions of below. Power rating 350 W Output voltage (VDC) 5 V 12 V 24 V 36 V 48 V Efficiency * 115 VAC input 77% typ. 83% typ. 86% typ. 87% typ. 87% typ. 230 VAC input 78% typ. 85% typ. 88% typ. 88% typ. 88% typ. Input Voltage range * Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373VDC Select with the switch. (The L terminal for the DC input is thepositive side and safety standards do not apply.) (Derating is requiredaccording to the input voltage. Refer to Derating Curves on Data Sheet.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 6.4 A typ. 230 VAC input 3.5 A typ. Power factor -- Leakagecurrent 115 VAC input 0.40 mA 0.40 mA 0.40 mA 0.40 mA 0.40 mA 230 VAC input 0.75 mA 0.80 mA 0.75 mA 0.80 mA 0.80 mA Inrushcurrent *(for a coldstart at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 60 A 29 A 14.6 A 9.7 A 7.32 A Voltage adjustment range * -10% to 10% (with V. ADJ) Ripple & Noisevoltage * 100 to 120VAC/200 to240 VAC input 110 mVp-pmax. 130 mVp-pmax. 120 mVp-pmax. 180 mVp-pmax. 180 mVp-pmax. Input variation influence * 0.5% max. Load variation influence * 2.0% max. 1.0% max. Temperaturevariationinfluence 100 to 120VAC/200 to240 VAC input 0.03%/°C max. Startuptime * 115 VAC input 610 ms typ. 620 ms typ. 580 ms typ. 610 ms typ. 610 ms typ. 230 VAC input 570 ms typ. 590 ms typ. 560 ms typ. 590 ms typ. 590 ms typ. Hold time * 115 VAC input 25 ms typ. 18 ms typ. 17 ms typ. 19 ms typ. 19 ms typ. 230 VAC input 31 ms typ. 25 ms typ. 23 ms typ. 25 ms typ. 24 ms typ. Addi-tionalfunc-tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off theinput voltage and turn on the input again) Overheat protection Yes, power shut off (shut off the input voltage and turn on the input again)(Overheat protection when the cooling fan is in an abnormal condition) Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula-tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals)current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) currentcutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) currentcutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PEterminals) at 500 VDC Envi-ron-ment Ambient operating temperature -20 to 60°C (Derating is required according to the temperature. Referto Derating Curves on Data Sheet.) (with no condensation or icing) Storage temperature -40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Zdirections10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Zdirections Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Relia-bility MTBF 135,000 hrs min. Life expectancy * 10 years min. Con-struc-tion Dimensions (W × H × D) Refer to Dimensions. Weight 800 g max. Cooling fan Yes (ON/OFF control according to internal temperature) Degree of protection -- Stan-dards Harmonic current emissions -- EMI ConductedEmissions Conforms to EN 61204-3 Class A, EN 55011 Class A RadiatedEmissions Conforms to EN 61204-3 Class A, EN 55011 Class A EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved StandardsUL: cURus UL 62368-1 (Recognition) OVC II Pol2CSA: cURus C22.2 No62368-1Conformed StandardsEN: EN 62368-1 OVC II Pol2RCM (EN61000-6-4)BIS: IS 13252 (Part1) (5 V, 24 V only) * Marine Standards No SEMI No * Refer to Conditions of below. Conditions Efficiency The value is given for the rated output voltage and rated output current. Input Voltage range Although some inverters give 50/60 Hz as the output frequency, do not use aninverter output as the power source for the Power Supply. Doing so may result insmoking or burning due to internal temperature increases in the Power Supply. If youconnect a UPS to the input, do not connect one with a square wave output. Frequency Current The value is given for the rated output voltage and rated output current. Inrush current(for a cold startat 25°C) The value is given for a cold start at 25°C. Refer to following for details. Output Voltageadjustment range If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by 10% ormore over the voltage adjustment range.When adjusting the output voltage, confirm the actual output voltage from the PowerSupply and be sure that load is not damaged. Ripple & Noisevoltage The value is given for the rated output voltage and rated output current.The value is for an ambient operating temperature of 25°C. Input variationinfluence This is the maximum variation in the output voltage when the input voltage isgradually changed within the allowable input voltage range at the rated output voltageand rated output current. Load variationinfluence This is the value when the output current is changed from 0 A to the rated outputcurrent while the input voltage is within the allowable input voltage. Startup time The value is given for the rated output voltage and rated output current.The value is given for a cold start at 25°C. Refer to following for details. Hold time The value is given for the rated output voltage and rated output current.Refer to following for details. Additionalfunctions Overvoltageprotection Refer to Overvoltage Protection on Data Sheet for information on resetting theinput power. Reliability Life expectancy Refer to Recommended Replacement Periods and Periodic Replacement forPreventive Maintenance on Data Sheet for details. List of Models with Bureau of Indian Standards (BIS) Certification This BIS Standard is an Indian standard that has been in effect for this product since April 2021, and certification has been acquired for belowmentioned models to enable individual product export to India. Model with terminalblock facing upward Model with terminalblock facing forward Model with DIN rail --- S8FS-C01505J S8FS-C01505D --- S8FS-C01524J S8FS-C01524D S8FS-C02505 S8FS-C02505J S8FS-C02505D S8FS-C02524 S8FS-C02524J S8FS-C02524D S8FS-C03524 S8FS-C03524J S8FS-C03524D S8FS-C05005 S8FS-C05005J S8FS-C05005D S8FS-C05012 S8FS-C05012J S8FS-C05012D S8FS-C05024 S8FS-C05024J S8FS-C05024D S8FS-C07524 S8FS-C07524J S8FS-C07524D S8FS-C07548 S8FS-C07548J S8FS-C07548D S8FS-C10024 S8FS-C10024J S8FS-C10024D S8FS-C10048 S8FS-C10048J S8FS-C10048D S8FS-C15012 S8FS-C15012J S8FS-C15012D S8FS-C15024 S8FS-C15024J S8FS-C15024D S8FS-C20024 S8FS-C20024J S8FS-C20024D S8FS-C35005 S8FS-C35005J S8FS-C35005D S8FS-C35024 S8FS-C35024J S8FS-C35024D Inrush Current, Startup Time, and Output Hold Time Note: Twice the normal input current will flow for a redundant system. Sufficiently check the fusing characteristics of fuses and the operating characteristics of breakers and select fuses and breakers so that external fuses will not burn out or breakers will not operate due to inrush current. Ripple Noise Voltage The specified standard for the ripple voltage noise was measured with the following measurement circuit.
Rs. 2,717.00 Rs. 1,603.03
-
RELAY BASE PTF08A-E FOR LY2N RELAYS, OMRON
DELIVERY PERIOD : 1-2 WEEKS Product Attribute Attribute Value Select Attribute Manufacturer: Omron Product Category: Relay Sockets & Fixings Delivery Restrictions: Mouser does not sell this product in your region. RoHS: Details Product: Relay Sockets Associated Relay Series: LY, SP, DP Termination Style: Screw Brand: Omron Automation and Safety Product Type: Relay Sockets & Hardware Series: PTF08A Factory Pack Quantity: 1 Subcategory: Relays Part # Aliases: 1340941 PTF08AE Unit Weight: 70 g
Rs. 519.00 Rs. 306.21
-
RELAY G2RV-SR700 DC24 MAKE OMRON WITH BASE
DELIVERY PERIOD : 1-2 WEEKS Manufacturer OMRON Type of relay interface Contacts configuration SPDT Control voltage 24V DC Max. operating current 6A AC contacts rating @R(at resistive load) at resistive load 6A / 250V AC DC contacts rating @R(at resistive load) at resistive load 6A / 30V DC Switched voltage max. 125V DC, max. 440V AC Mounting for DIN rail mounting Manufacturer series G2RV-SR Leads screw terminals Relay variant Relay set Operate time 20ms Release time 40ms Operating temperature -40...55°C Contact material silver alloy Body dimensions 88.8x6.2x78mm Contact resistance 100m Mechanical durability 5000000 cycles Electrical life 50000 cycles Gross weight29.2 g
Rs. 1,112.00 Rs. 656.08
-
LIMIT SWITCH WLCA12
DELIVERY PERIOD : 1-2 WEEKS Product Attribute Attribute Value Select Attribute Manufacturer: Omron Product Category: Limit Switches RoHS: Details REACH - SVHC: Details Illuminated: Non-Illuminated Contact Form: DPDT Actuator: Roller Lever Current Rating: 100 mA Voltage Rating AC: 125 VAC Voltage Rating DC: 30 VDC Operating Force: 13.34 N Termination Style: Screw Mounting Style: Chassis Mount IP Rating: IP67 Actuator Style: Roller Lever Brand: Omron Automation and Safety Product Type: Limit Switches Series: WL Factory Pack Quantity: 1 Subcategory: Switches Type: Two-Circuit Limit Switch Part # Aliases: WLCA122N Unit Weight: 275 g
Rs. 6,274.00 Rs. 3,701.66
-
PROXIMITY SENSOR,MODEL : E2E-X7D1-M1G SN : 7 MM M18 SHIELDED DC 2 WIRE,OMRON MAKE
DELIVERY PERIOD : 1-2 WEEKS Attribute Value Select Attribute Brand: Omron Automation and Safety Description/Function: NO Height: 29 mm Length: 47 mm Maximum Operating Temperature: + 70 C Minimum Operating Temperature: - 25 C Product Type: Proximity Sensors Series: E2EQ Factory Pack Quantity: 1 Subcategory: Sensors Width: 29 mm Part # Aliases: E2EQX7D1 Unit Weight: 40 g
Rs. 6,442.00 Rs. 3,800.78
-
RELAY,G7SA-4A2B DC24 MAKE - OMRON
Degree of protection Flux tight Terminal structure PCB terminal Coil Coil ratings 24 VDC 20.8 mA Coil resistance 1152 Ω Operate voltage (Set voltage) 75 % max. Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 500 mW Contact Contact rated load 250 VAC 6 A (Resistive load)30 VDC 6 A (Resistive load) Max. contact voltage 250 VAC125 VDC Max. contact current AC: 6 ADC: 6 A Contact form 4PST-NO/DPST-NC Contact material Au plating+Ag alloy Performance Contact resistance 100 mΩ max. (Voltage drop method with 5 VDC 1 A) Operating time 20 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) Reset time 20 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) Maximum operating frequency Mechanical: 36000 time/hourRated load: 1800 time/hour Insulation resistance Between coil and contacts: 1000 MΩ min. (at 500 VDC)Between contacts of different polarity: 1000 MΩ min. (at 500 VDC)Between contacts of same polarity: 1000 MΩ min. (at 500 VDC) Dielectric strength Between coil and contacts: 4000 VAC 50/60 Hz 1 minBetween contacts of different polarity (Between pole 3 and pole 5_pole 4 and pole 6_pole 5 and pole 6): 2500 VAC 50/60 Hz 1 minBetween contacts of different polarity (Except for between pole 3 and pole 5_pole 4 and pole 6_pole 5 and pole 6): 4000 VAC 50/60 Hz 1 minBetween contacts of same polarity: 1500 VAC 50/60 Hz 1 min Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance (destruction) 1000 m/s2 Shock resistance (Malfunction) 100 m/s2 Endurance (Mechanical) 10,000,000 operations min. (switching frequency 36,000 operations/h) Endurance (Electrical) 100,000 operations min. (rated load) Failure rate 5 VDC 1 mA (failure level: Preference value, Switching frequency: 300 operations per minute) Ambient temperature (Operating) -40 to 85 ℃ (with no freezing or condensation) Ambient humidity (Operating) 5 to 85 % Weight Approx. 25 g Mounting method Socket, Soldering Applicable socket P7SA-14F/ P7SA-14F-ND/ P7SA-14P/ P7SA-14F-ND-PU
Rs. 3,465.00 Rs. 1,732.50