Automation Products
-
Rs. 3,776.00
-
MODEL-PLC HIGH SPEED INPUT MODULE QX80H MITSHUBISHI
Digital Input Module Series MELSEC-Q SERIES Type DC HIGH-SPEED INPUT Power Supply (V) 24 Current Type DC Occupied I/O Points on PLC 16 Integrated Digital Inputs 16 Rated Input Voltage (VDC) 24 Wiring SCREW Int. Current Consumption (A) 0,08 Product Dimensions & Weight Width (mm) 27,4 Height (mm) 98 Depth (mm) 90 Weight (kg) 0,16
Rs. 8,850.00
-
MODEL-PLC BLANK COVER MODULE QG60 MAKE MITSHUBISHI
Specifications Primary brand Mitsubishi Electric Main function Cover Product series / family name Industrial automation > PLCs (Programmable Logic Controllers) > Various accessories Functions Blanking module (fills unused slots) Order code / Manufacturer SKU QG60 Manufacturer product status Commercialized
Rs. 1,321.60
-
MODEL-ELCT00596- EMERGENCY PUSH BUTTON MAKE SCHNEIDER
About This Product Key Features Easy to Install & Compatible with Standard Control Panels for Seamless Integration. Durable & Highly Visible Red Mushroom Head for Quick & Easy Activation in Emergencies. Robust Construction with Ip65 Rating Ensures Reliable Operation in Harsh Industrial Environments. Product Specifications Brand Schneider Electric Standards UL 508,EN/IEC 60947-5-5,EN/IEC 60947-5-4,EN/IEC 60947-5-1,EN/ISO 13850 JIS C8201-1 Depth 82 mm Dimensions 4.5x5.4x9.6 cm
Rs. 242.20
-
MODEL- VFD DRIVE MODEL N0.FR-E840-0060-4-60 MITSUBISHI
Specifications Series Type Model name Inverter capacity (kW) Applicable motor capacity (kW)*1 LD ND Output Rated capacity (kVA)*2 LD ND Rated current (A)*7 LD ND Overload current rating*3 LD ND Voltage*4 Regenerative braking Brake transistor Maximum brake torque (ND reference)*5 Power supply Rated input AC voltage and frequency Permissible AC voltage fluctuation Permissible frequency fluctuation Rated input current (A) without DC reactor*8 LD ND Rated input current (A) with DC reactor*8 LD ND Power supply capacity (kVA) without DC reactor*6 LD ND Power supply capacity (kVA) with DC reactor*6 LD ND Protective structure IEC 60529 Cooling system Approx. mass (kg) Control Control method Common Induction motor PM motor Output frequency range Induction motor PM motor Frequency setting and resolution Analog input Digital input Frequency accuracy Analog input Digital input Voltage/frequency characteristics Starting torque*14 Induction motor PM motor Torque boost Acceleration/deceleration time setting DC injection brake Induction motor PM motor Stall prevention operation level Torque limit level Operation Frequency setting signal Number of analog input Specification of analog input Digital input Start signal Input signal Number of input signal (Contact input) Input terminal function selectable signal Operational function Output signal Number of output signal (Open collector output) Number of output signal (Relay output) Output terminal function selectable signal Pulse train output (FM type inverter) Analog output (AM type inverter) Protective/warning function Protective function Warning function Environment Surrounding air temperature Surrounding air humidity Storage temperature*12 Ambience Altitude/vibration Network FR-E800 Three-phase 400 V class Standard model FR-E840-0060-4-60 2.2 3.0 2.2 5.3 4.6 6.9 (5.9) 6.0 (5.4) 120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C 150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C Three-phase 380 to 480 V Built-in 20 % Three-phase 380 to 480 V, 50/60 Hz (537 to 679 VDC*9) 323 to 528 V, 50/60 Hz (457 to 740 VDC*9) ±5 % 10.7 9.5 6.9 6.0 8.2 7.2 5.3 4.6 IP20 Forced air 1.8 Soft-PWM control/High carrier frequency PWM control Selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, and Vector control*10 PM sensorless vector control 0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control, Real sensorless vector control, and Vector control*10.) 0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency) 0.015 Hz/60 Hz at 0 to 10 V/12 bits (terminals 2 and 4)0.03 Hz/60 Hz at 0 to 5 V/11 bits or 0 to 20 mA/11 bits (terminals 2 and 4) 0.01 Hz Within ±0.2 % of the maximum output frequency (25 °C ±10 °C) 0.01 % or less of the set output frequency Base frequency can be set from 0 to 590 Hz. Constant-torque/variable-torque pattern can be selected (with induction motor only). The following is the specifications for the ND rating.30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V/F control)150 % at 0.5 Hz (Advanced magnetic flux vector control)200 % at 0.3 Hz (0.1K to 3.7K), 150 % at 0.3 Hz (5.5K or higher) (Real sensorless vector control)200 % at 0 Hz (0.1K to 3.7K), 150 % at 0 Hz (5.5K or higher) (Vector control*10) The following is the specifications for the ND rating.50 % (with a motor other than MM-GKR or EM-A)200 % (with MM-GKR or EM-A) Manual torque boost (induction motor only) 0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration modes are available. Operation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable Operation time (0 to 10 s) variable. Operating voltage (operating current) fixed. Operation current : 0 to 200 % variable, with selectable availability of the function Torque limit value can be set (0 to 400 % variable). (Real sensorless vector control, Vector control*10, PM sensorless vector control) 2 Terminals 2 and 4 : 0 to 10 V/0 to 5 V/4 to 20 mA (0 to 20 mA) Input using the operation panel.Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX E kit is installed). Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected. 7 Low-speed operation command, Middle-speed operation command, High-speed operation command, Output stop, Forward rotation command, Reverse rotation command, Inverter resetThe signal to be input can be changed using Pr.178 to Pr.184 (Input terminal function selection). Maximum and minimum frequency settings, Multi-speed operation, Acceleration/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, Frequency jump, Rotation display, Automatic restart after instantaneous power failure, Remote setting, Automatic acceleration/deceleration, Retry function, Carrier frequency selection, Fast-response current limit, Forward/reverse rotation prevention, Operation mode selection, Slip compensation, Droop control, Speed smoothing control, Traverse, Auto tuning, Applied motor selection, RS-485 communication, PID control, Easy dancer control, Cooling fan operation selection, Stop selection, Power failure time deceleration-to-stop function, Stop-on-contact control, PLC function, Life diagnosis, Maintenance timer, Current average monitor, Multiple rating, Speed control, Torque control, etc 2 1 Inverter running, Up to frequency, FaultThe signal to be output can be changed using Pr.190 to Pr.192 (Output terminal function selection). Not used -10 to +10 V/12 bits Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay function), Heat sink overheat, Undervoltage, Input phase loss, Stall prevention stop, Loss of synchronism detection*11, Upper limit fault detection, Lower limit fault detection, Brake transistor alarm detection, Output side earth (ground) fault overcurrent, Output short circuit, Output phase loss, External thermal relay operation, PTC thermistor operation*11, Option fault, Communication option fault, Parameter storage device fault, PU disconnection, Retry count excess, CPU fault, Abnormal output current detection, Inrush current limit circuit fault, USB communication fault, etc Fan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Regenerative brake pre-alarm*11, Electronic thermal relay function pre-alarm, PU stop, Maintenance timer alarm, Parameter write error, Operation panel lock*11, Password locked*11, Speed limit indication*11, Stroke limit warning*11, Home position return setting error*11, Home position return uncompleted*11, Safety stop, Incorrect parameter setting -20 °C to +60 °C (The rated current must be reduced at a temperature above 50 °C.) 95 % RH or less (non-condensing) -40 °C to +70 °C Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) Maximum 3000 m*13, 5.9 m/s2 or less at 10 to 55 Hz in X, Y, and Z directions RS-485 : Mitsubishi inverter protocol, MODBUS RTU, BACnet MS/TPOption unit : CC-Link, DeviceNet, PROFIBUS-DPV0 (*1)The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric 4-pole standard motor.To drive a Mitsubishi Electric high-performance energy-saving motor, use the 2.2K inverter for a 3 kW motor. (*2)The rated output capacity is the value with respect to 440 V output voltage. (*3)The percentage of the overload current rating is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the inverter and motor to return to or below the temperatures under 100 % load. (*4)The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.The maximum point of the voltage waveform at the output side of the inverter is approximately the power supply voltage multiplied by √2. (*5)The amount of braking torque is the average short-term torque (which varies depending on motor loss) that is generated when a motor decelerates in the shortest time by itself from 60 Hz. It is not continuous regenerative torque. The average deceleration torque becomes lower when a motor decelerates from a frequency higher than the base frequency. The inverter is not equipped with a built-in brake resistor. Use an option brake resistor for an operation with large regenerative power. The brake unit (FR-BU2) can be also used. (*6)The power supply capacity varies with the value of the input power impedance (including those of the input reactor and cables). (*7)The value in parentheses is the rated output current when the low acoustic noise operation is performed with the surrounding air temperature exceeding 40 °C while 2 kHz or higher value is selected in Pr.72 PWM frequency selection. (*8)The rated input current is the value at a rated output voltage. The input power impedances (including those of the input reactor and cables) affect the value. (*9)· Connect the DC power supply to the inverter terminals P/+ and N/-. Connect the positive terminal of the power supply to terminal P/+ and the negative terminal to terminal N/-.· When the energy is regenerated from the motor, the voltage between terminals P/+ and N/- may temporarily rise to 830 V or more. Use a DC power supply resistant to the regenerative voltage/energy. When a power supply that cannot resist the regenerative voltage/energy is used, connect a reverse current prevention diode in series.· Powering ON produces up to four times as large current as the inverter rated current. Prepare a DC power supply resistant to the inrush current at power ON, although an inrush current limit circuit is provided in the FR-E800 series inverter.· The power capacity depends on the output impedance of the power supply. Select a power capacity around the AC power supply capacity. (*10)Available when a Vector control compatible option (FR-A8AP E kit) is installed. (*11)Not activated in the inverter in the initial state. (*12)Applicable to conditions for a short time, for example, in transit. (*13)For the installation at an altitude above 1000 m, consider a 3 % reduction in the rated current per 500 m increase in altitude. (*14)The value is the initial setting.
Rs. 31,860.00
-
MODEL- ACB COIL, MN/UVR 380-480 VAC
Model No 33673 Type of Product Voltage Release Frequency 50/60 Hz Range ComPacT
Rs. 12,046.00
-
MODEL- ACB COIL, MN/UVR 380-480 VAC
Model No 33673 Type of Product Voltage Release Frequency 50/60 Hz Range ComPacT
Rs. 14,691.00
-
MODEL- ACB COIL, MX-XF/SHT-SHC/COM, 200-250V, AC-DC SCHNIEDER
Item specifics Condition Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is ... Read moreabout the condition Brand Schneider Type VOLTAGE RELEASE Model MX-XF/SHT-SHC MPN MX-XF/SHT-SHC Controller Platform SHUNT TRIP/CLOSE Country of Origin France
Rs. 15,635.00
-
MODEL-MCCB 4P,100,CVS100B
Specifications
Rs. 5,322.15
-
MODEL-MCCB 3P,250A, LV525333 (CVS25 OF)
Brand Schneider Electric Current Rating 250 Amps Product Dimensions 5D x 5W x 10H Centimeters Circuit Breaker Type Standard Mounting Type Mounted About this item A moulded case circuit breaker (MCCB) is a type of electrical protection device that is used to protect the electrical circuit from excessive current, which can cause overload or short circuit LV525333 has a Thermal Magnetic Trip Unit and breaking capacity of 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 Dimensions H 161mm x W 105mm x D 86mm Green Premium Product - Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
Rs. 12,303.39
-
MODEL-CONTACTOR WITH COIL LC1G115, 3P, 115A (110VAC COIL)
MODEL-CONTACTOR WITH COIL LC1G115, 3P, 115A (110VAC COIL)
Rs. 13,215.88
-
MODEL-CONTACTOR WITH COIL LC1G185, 3P, 185A(110VAC COIL)
Designed to meet needs of demanding applications built-in with advanced features and functionalities Fewer references covering wider applications means simpler to select and less inventory to carry Coil designed for less energy consumption and wider voltage band-width Modular design and compact size for easy maintenance, short down times and less installation space consumption IEC 60335 certificates by authorized agency
Rs. 21,602.97