Automation Products
-
MODEL- PROXIMITY SWITCH CAT NO E2E-X7D2-N MAKE OMRON
Product Attribute Attribute Value Select Attribute Manufacturer: Omron Product Category: Proximity Sensors - Industrial RoHS: Technology: Inductive Measuring Range - Max: 7 mm Output Type: NPN-NC Mounting Style: Panel Mount Connection Method: Pre-Cable Cable Length: 2 m Coding: D Coded Supply Voltage - Min: 12 VDC Supply Voltage - Max: 24 VDC Series: E2E Brand: Omron Automation and Safety IP Rating: IP67 Maximum Frequency: 500 Hz Maximum Operating Temperature: + 70 C Minimum Operating Temperature: - 25 C Product Type: Proximity Sensor 1 Subcategory: Sensors Part # Aliases: E2EX7D2NQ E2EX7D2N Unit Weight: 192.780 g
Rs. 2,000.00
-
MODEL- PROXIMITY SENSOR E2B-S08KN04-WP-B1 MAKE OMRON
Specifications Size M8 Mounting type Non-flush Sensing distance 4 mm Output type PNP Operation mode NO Connection method Cable Material housing Stainless steel Cable specifications PVC Cable length 2 m Overall length of sensor 42 mm Thread length 21 mm Degree of protection (IP) IP67
Rs. 650.00
-
MODEL- PROXIMITY SENSOR 6-36VDC PNP NO SN 8MM
The M18 PNP No Inductive Proximity Sensor is a highly reliable and precise sensing device designed for detecting the presence of metal objects without physical contact. Operating with a 6-36 VDC power supply, it uses an inductive sensing mechanism to detect metallic objects within a 8mm sensing range, making it suitable for a variety of industrial, automation, and mechanical applications. The M18 refers to the size and shape of the sensor, with a cylindrical housing of 18mm in diameter, commonly used for proximity sensing in machines and equipment. This proximity sensor is of the PNP type, meaning it provides a positive switching output when a metal object is detected. The sensor is NO (Normally Open), which means the output is only triggered when an object enters the sensing range. The sensor is designed to offer high precision and durable operation in tough environments such as manufacturing plants, assembly lines, and automated systems. It comes with a 2-meter 3-core cable, making installation simple and flexible for different setups. The M18 PNP proximity sensor is widely used for object detection, position sensing, machine safety, and other industrial automation tasks where metal objects need to be sensed with high reliability. Applications Industrial machinery object detection Automated conveyor systems Robotic position sensing Limit switch replacement Metal target detection in harsh environments Features M18 threaded cylindrical design for easy installation PNP Normally Open output type 6 to 36V DC wide operating voltage 8mm non-contact sensing distance Durable construction with high resistance to wear Compatible with automation systems and PLCs Includes 2 meter long 3-core cable Specifications Parameter Details Sensor Type Inductive Proximity Sensor Threaded Size M18 Output Type PNP Normally Open Sensing Distance 8mm Operating Voltage 6 to 36V DC Output Current ≤ 200 mA Response Frequency 500 Hz (typical) Detection Target Ferrous metals Cable Length 2 meters Cable Type 3-core PVC insulated cable Indicator Built-in LED operation indicator Housing Material Nickel-plated brass or ABS (varies) Installation Type Flush mount or non-flush Operating Temperature -25°C to +70°C Protection Rating IP67
Rs. 320.00
-
MODEL- PROX. SENSOR M18 P.NO: NCB5-18GM40-Z0,P AND F
Inductive sensor Key Benefits at a Glance Comfort series 5 mm flush 2-wire DC
Rs. 1,360.00
-
MODEL- PROGRAMMABLE DIGITAL TIMER-MULTI FUNCTION ID V7DFTS3 SUPPLY 110-240VAC MAKE GIC
programmable digital timer 7-Segment display Supply Voltage range of 110-240 VAC Input Signal Sensing range of 85-265 VAC/100-265 VDC & 20-60 VAC/DC Inbuilt library of 35 functions covering majority applications multifunction digital timer Easy steps to program customized functions
Rs. 1,480.00
-
MODEL- PRESS SWITCH HED 8OA-2X/350K14AS REXROTH
Item specifics Condition New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. Brand Rexroth Model R901102710 MPN Does Not Apply Country of Origin China
Rs. 16,052.40
-
MODEL- POWERRELAY F3A012E 12VDC 5A FUJI
Specifications Brand Fujitsu Coil Voltage 12V dc Contact Configuration SPST Mounting Type PCB Mount Switching Current 5A Number of Poles 1 Latching No Terminal Type PCB Pin Maximum Switching Voltage AC 277V ac Maximum Switching Voltage DC 30V dc Length 20.3mm Coil Resistance 720Ω Coil Power 200mW Minimum Operating Temperature -40°C Maximum Operating Temperature +70°C Isolation Coil To Contact 10kV Depth 7mm Life 100 x 10³ Operations Height 15mm Contact Material Silver Alloy Maximum Switching Power DC 150 W Maximum Switching Power AC 1.25 kVA Application Power
Rs. 220.00
-
MODEL- POWER CARD , FL- TX4- DI04- PS- 24 V
Brand Name Selec Model Selec flexys tx4 FL-TX4-DI04-PS-24V-CE-RoHS Usage Application Industrial Model No FL-TX4-DI04-PS-24V-CE-RoHS Type 1 Selec flexys tx4 Availability In Stock
Rs. 1,890.00
-
MODEL- PLC MODEL A1SJ71UC24-R2 5VDC 0-10A MITSUBISHI MAKE
About this product Product Identifiers BrandMitsubishi MPNA1SJ71UC24-R2 eBay Product ID (ePID)141020112
Rs. 6,650.00
-
MODEL- PLC 6ES7315-2EH14-0AB0(LASER WELDING )
Product type designation CPU 315-2 PN/DP HW functional status 01 Firmware version V3.2 Product function ● Isochronous mode Yes; Via PROFIBUS DP or PROFINET interface Engineering with ● Programming package STEP 7 V5.5 or higher Supply voltage Rated value (DC) 24 V permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V external protection for power supply lines (recommendation) 2 A min. Mains buffering ● Mains/voltage failure stored energy time 5 ms ● Repeat rate, min. 1 s Input current Current consumption (rated value) 750 mA Current consumption (in no-load operation), typ. 150 mA Inrush current, typ. 4 A I²t 1 A²·s Power loss Power loss, typ. 4.65 W Memory Work memory ● integrated 384 kbyte ● expandable No Load memory ● Plug-in (MMC) Yes ● Plug-in (MMC), max. 8 Mbyte ● Data management on MMC (after last programming), min. 10 a Backup ● present Yes; Guaranteed by MMC (maintenance-free) ● without battery Yes; Program and data CPU processing times for bit operations, typ. 0.05 µs for word operations, typ. 0.09 µs for fixed point arithmetic, typ. 0.12 µs for floating point arithmetic, typ. 0.45 µs CPU-blocks Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. DB ● Number, max. 1 024; Number range: 1 to 16000 ● Size, max. 64 kbyte FB ● Number, max. 1 024; Number range: 0 to 7999 ● Size, max. 64 kbyte FC ● Number, max. 1 024; Number range: 0 to 7999 ● Size, max. 64 kbyte OB ● Size, max. 64 kbyte ● Number of free cycle OBs 1; OB 1 ● Number of time alarm OBs 1; OB 10 ● Number of delay alarm OBs 2; OB 20, 21 ● Number of cyclic interrupt OBs 4; OB 32, 33, 34, 35 ● Number of process alarm OBs 1; OB 40 ● Number of DPV1 alarm OBs 3; OB 55, 56, 57 ● Number of isochronous mode OBs 1; OB 61 ● Number of startup OBs 1; OB 100 ● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO) ● Number of synchronous error OBs 2; OB 121, 122 Nesting depth ● per priority class 16 ● additional within an error OB 4 Counters, timers and their retentivity S7 counter ● Number 256 Retentivity — adjustable Yes — preset Z 0 to Z 7 Counting range — adjustable Yes — lower limit 0 — upper limit 999 IEC counter ● present Yes ● Type SFB ● Number Unlimited (limited only by RAM capacity) S7 times ● Number 256 Retentivity — adjustable Yes — preset No retentivity Time range — lower limit 10 ms — upper limit 9 990 s IEC timer ● present Yes ● Type SFB ● Number Unlimited (limited only by RAM capacity) Data areas and their retentivity Retentive data area (incl. timers, counters, flags), max. 128 kbyte Flag ● Size, max. 2 048 byte ● Retentivity available Yes; MB 0 to MB 2 047 ● Retentivity preset MB 0 to MB 15 ● Number of clock memories 8; 1 memory byte Data blocks ● Retentivity adjustable Yes; via non-retain property on DB ● Retentivity preset Yes Local data ● per priority class, max. 32 768 byte; Max. 2048 bytes per block Address area I/O address area ● Inputs 2 048 byte ● Outputs 2 048 byte of which distributed — Inputs 2 048 byte — Outputs 2 048 byte Process image ● Inputs 2 048 byte ● Outputs 2 048 byte ● Inputs, adjustable 2 048 byte ● Outputs, adjustable 2 048 byte ● Inputs, default 128 byte ● Outputs, default 128 byte Subprocess images ● Number of subprocess images, max. 1; With PROFINET IO, the length of the user data is limited to 1600 bytes Digital channels ● Inputs 16 384 — of which central 1 024 ● Outputs 16 384 — of which central 1 024 Analog channels ● Inputs 1 024 — of which central 256 ● Outputs 1 024 — of which central 256 Hardware configuration Number of expansion units, max. 3 Number of DP masters ● integrated 1 ● via CP 4 Number of operable FMs and CPs (recommended) ● FM 8 ● CP, PtP 8 ● CP, LAN 10 Rack ● Racks, max. 4 ● Modules per rack, max. 8 Time of day Clock ● Hardware clock (real-time) Yes ● retentive and synchronizable Yes ● Backup time 6 wk; At 40 °C ambient temperature ● Deviation per day, max. 10 s; Typ.: 2 s ● Behavior of the clock following POWER-ON Clock continues running after POWER OFF ● Behavior of the clock following expiry of backup period the clock continues at the time of day it had when power was switched off Operating hours counter ● Number 1 ● Number/Number range 0 ● Range of values 0 to 2^31 hours (when using SFC 101) ● Granularity 1 h ● retentive Yes; Must be restarted at each restart Clock synchronization ● supported Yes ● to MPI, master Yes ● on MPI, device Yes ● to DP, master Yes; With DP slave only slave clock ● on DP, device Yes ● in AS, master Yes ● in AS, device Yes ● on Ethernet via NTP Yes; As client Digital inputs Number of digital inputs 0 Digital outputs Number of digital outputs 0 Analog inputs Number of analog inputs 0 Interfaces Number of PROFINET interfaces 1; 2 ports (switch) RJ45 Number of RS 485 interfaces 1; Combined MPI / PROFIBUS DP Number of RS 422 interfaces 0 1. Interface Interface type Integrated RS 485 interface Isolated Yes Interface types ● RS 485 Yes ● Output current of the interface, max. 200 mA Protocols ● MPI Yes ● PROFIBUS DP master Yes ● PROFIBUS DP device Yes ● Point-to-point connection No MPI ● Transmission rate, max. 12 Mbit/s Services — PG/OP communication Yes — Routing Yes — Global data communication Yes — S7 basic communication Yes — S7 communication Yes — S7 communication, as client No; but via CP and loadable FB — S7 communication, as server Yes PROFIBUS DP master ● Transmission rate, max. 12 Mbit/s ● max. number of DP devices 124 Services — PG/OP communication Yes — Routing Yes — Global data communication No — S7 basic communication Yes; I blocks only — S7 communication Yes — S7 communication, as client No — S7 communication, as server Yes — Equidistance Yes — Isochronous mode Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO — SYNC/FREEZE Yes — activation/deactivation of DP devices Yes — max. number of DP devices that can be activated/deactivated at the same time 8 — Direct data exchange (slave-to-slave communication) Yes; as subscriber — DPV1 Yes Address area — Inputs, max. 2 kbyte — Outputs, max. 2 kbyte User data per DP device — Inputs, max. 244 byte — Outputs, max. 244 byte PROFIBUS DP device ● Transmission rate, max. 12 Mbit/s ● automatic baud rate search Yes; only with passive interface ● Address area, max. 32 ● User data per address area, max. 32 byte Services — PG/OP communication Yes — Routing Yes; Only with active interface — Global data communication No — S7 basic communication No — S7 communication Yes — S7 communication, as client No — S7 communication, as server Yes; Connection configured on one side only — Direct data exchange (slave-to-slave communication) Yes — DPV1 No Transfer memory — Inputs 244 byte — Outputs 244 byte 2. Interface Interface type PROFINET Isolated Yes automatic detection of transmission rate Yes; 10/100 Mbit/s Autonegotiation Yes Autocrossing Yes Change of IP address at runtime, supported Yes Interface types ● RJ 45 (Ethernet) Yes ● Number of ports 2 ● integrated switch Yes Protocols ● MPI No ● PROFINET IO Controller Yes; Also simultaneously with IO-Device functionality ● PROFINET IO Device Yes; Also simultaneously with IO Controller functionality ● PROFINET CBA Yes ● PROFIBUS DP master No ● PROFIBUS DP device No ● Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP ● Web server Yes ● Media redundancy Yes PROFINET IO Controller ● Transmission rate, max. 100 Mbit/s Services — PG/OP communication Yes — Routing Yes — S7 communication Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32 — Isochronous mode Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO — IRT Yes — Shared device Yes — Prioritized startup Yes — Number of IO devices with prioritized startup, max. 32 — Number of connectable IO Devices, max. 128 — Of which IO devices with IRT, max. 64 — of which in line, max. 64 — Number of IO Devices with IRT and the option "high flexibility" 128 — of which in line, max. 61 — Number of connectable IO Devices for RT, max. 128 — of which in line, max. 128 — Activation/deactivation of IO Devices Yes — Number of IO Devices that can be simultaneously activated/deactivated, max. 8 — IO Devices changing during operation (partner ports), supported Yes — Number of IO Devices per tool, max. 8 — Device replacement without swap medium Yes — Send cycles 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option) — Updating time 250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, technical Data" for more details) Address area — Inputs, max. 2 kbyte — Outputs, max. 2 kbyte — User data consistency, max. 1 024 byte PROFINET IO Device Services — PG/OP communication Yes — Routing Yes — S7 communication Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32 — Isochronous mode No — IRT Yes — PROFIenergy Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device — Shared device Yes — Number of IO Controllers with shared device, max. 2 Transfer memory — Inputs, max. 1 440 byte; Per IO Controller with shared device — Outputs, max. 1 440 byte; Per IO Controller with shared device Submodules — Number, max. 64 — User data per submodule, max. 1 024 byte PROFINET CBA ● acyclic transmission Yes ● cyclic transmission Yes Open IE communication ● Number of connections, max. 8 ● Local port numbers used at the system end 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 ● Keep-alive function, supported Yes Protocols PROFIsafe No Redundancy mode Media redundancy — Switchover time on line break, typ. 200 ms; PROFINET MRP — Number of stations in the ring, max. 50 Open IE communication ● TCP/IP Yes; via integrated PROFINET interface and loadable FBs — Number of connections, max. 8 — Data length for connection type 01H, max. 1 460 byte — Data length for connection type 11H, max. 32 768 byte — several passive connections per port, supported Yes ● ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface and loadable FBs — Number of connections, max. 8 — Data length, max. 32 768 byte ● UDP Yes; via integrated PROFINET interface and loadable FBs — Number of connections, max. 8 — Data length, max. 1 472 byte Web server ● supported Yes ● User-defined websites Yes ● Number of HTTP clients 5 Communication functions PG/OP communication Yes Data record routing Yes Global data communication ● supported Yes ● Number of GD loops, max. 8 ● Number of GD packets, max. 8 ● Number of GD packets, transmitter, max. 8 ● Number of GD packets, receiver, max. 8 ● Size of GD packets, max. 22 byte ● Size of GD packet (of which consistent), max. 22 byte S7 basic communication ● supported Yes ● User data per job, max. 76 byte ● User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) S7 communication ● supported Yes ● as server Yes ● as client Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB ● User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) S5 compatible communication ● supported Yes; via CP and loadable FC PROFINET CBA (at set setpoint communication load) ● Setpoint for the CPU communication load 50 % ● Number of remote interconnection partners 32 ● number of master/device functions 30 ● total of all master/device connections 1 000 ● data length of all incoming master/device connections, max. 4 000 byte ● data length of all outgoing master/device connections, max. 4 000 byte ● Number of device-internal and PROFIBUS interconnections 500 ● Data length of device-internal und PROFIBUS interconnections, max. 4 000 byte ● Data length per connection, max. 1 400 byte
Rs. 185,000.00
-
MODEL- PILZ RELAY MODEL- 777301
Number Of Poles 4 Pole Brand PILZ Usage/Application Industrial Model Name/Number 777301 Type Voltage Relays Relay Modules Bench Warranty 1 YEAR I Deal In New Only Voltage Type DC Availability In Stock
Rs. 15,670.00
-
MODEL- PHOTO ELECTRIC SENSOR MAKE BANNER (QS18VP6LP)
Sensor Type Reflector Sensing Distance 3.5 meter Model Name/Number QS18VP6LP Voltage 10-30 VDC Size/Dimension M18 Dai Usage/Application Industrial Degree Of Protection IP65 Short Circuit Protection Yes Color Yellow Control Output NPN Sensing Method Retro Reflective Availability In Stock
Rs. 3,290.50