MODEL-LIMIT SWITCH OMRON D4B-2171N

Description

DELIVERY PERIOD : 1-2 WEEKS 

Operating mechanism Snap action
ctuator Top roller plunger 12.7 dia. x 4.8
Stainless steel roller
Frequency 50/60 Hz
Contact form 1NC/1NO
Load General load
Ratings (AC): Non-Inductive load Resistive load: 10 A at 125 VAC/10 A at 250 VAC/10 A at 400 VAC
Lamp load (NC): 3 A at 125 VAC/2 A at 250 VAC/1.5 A at 400 VAC
Lamp load (NO): 1.5 A at 125 VAC/1 A at 250 VAC/0.8 A at 400 VAC
Inductive load: 10 A at 125 VAC/10 A at 250 VAC/3 A at 400 VAC
Motor load (NC): 5 A at 125 VAC/3 A at 250 VAC/1.5 A at 400 VAC
Motor load (NO): 2.5 A at 125 VAC/1.5 A at 250 VAC/0.8 A at 400 VAC
Ratings (DC): Non-Inductive load Resistive load: 10 A at 8 VDC/10 A at 14 VDC/6 A at 30 VDC/0.8 A at 125 VDC/0.4 A at 250 VDC
Lamp load (NC): 6 A at 8 VDC/6 A at 14 VDC/4 A at 30 VDC/0.2 A at 125 VDC/0.1 A at 250 VDC
Lamp load (NO): 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/0.2 A at 125 VDC/0.1 A at 250 VDC
Inductive load: 10 A at 8 VDC/10 A at 14 VDC/6 A at 30 VDC/0.8 A at 125 VDC/0.4 A at 250 VDC
Motor load: 6 A at 8 VDC/6 A at 14 VDC/4 A at 30 VDC/0.2 A at 125 VDC/0.1 A at 250 VDC
Inrush current 30 A max.
Conduit G1/2 (PF1/2)
Earth terminal With ground terminal
Ambient temperature Operating: -40 to 80 ℃ (with no icing)
Ambient humidity 95 %RH max.
Permissible operating speed 1 mm/s to 0.5 m/s
Permissible operating frequency Electrical: 30 operations / 1 minute max.
Mechanical: 120 operations / 1 minute max.
Contact resistance (Initial value) 25 mΩ max.
Insulation resistance Between each terminal of the same polarities: 100 MΩ min.
Between each terminal and non-live-metallic part: 100 MΩ min.
at 500 VDC
Impulse withstand voltage Between each terminal of the same polarities: 2.5 kV
Between each terminaland ground: 4 kV
Durability Electrical: 500,000 operations min. (10 A at 250 VAC)
Mechanical: 30 million operations min.
Vibration resistance Malfunction: 10 to 55 Hz, 0.75 mm single amplitude
Shock resistance Destruction: 1000 m/s2 min.
Malfunction: 300 m/s2 min.
Degree of protection IP67
Classification of protection against electric shock Class I (with ground terminal)
Operating Force (OF) Standard value 18.63 N max.
Release Force (RF) Standard value 1.96 N min.
Pre-Travel (PT) Standard value 2 mm max.
Movement Differential (MD) Standard value 1 mm max.
Over-Travel (OT) Standard value 5 mm min.
Operating Position (OP) Standard value 48±1 mm
Total Travel (TT) Reference value 7 mm
Free Position (FP) Standard value 51 mm max.
Direct Opening Force Standard value 49.03 N min.
Direct Opening Travel Standard value 3.2 mm min.

MODEL-LIMIT SWITCH OMRON D4B-2171N

Product form

DELIVERY PERIOD : 1-2 WEEKS  Operating mechanism Snap action ctuator Top roller plunger 12.7 dia. x 4.8Stainless steel roller Frequency... Read more

Rs. 2,200.00 Incl. VAT

      Description

      DELIVERY PERIOD : 1-2 WEEKS 

      Operating mechanism Snap action
      ctuator Top roller plunger 12.7 dia. x 4.8
      Stainless steel roller
      Frequency 50/60 Hz
      Contact form 1NC/1NO
      Load General load
      Ratings (AC): Non-Inductive load Resistive load: 10 A at 125 VAC/10 A at 250 VAC/10 A at 400 VAC
      Lamp load (NC): 3 A at 125 VAC/2 A at 250 VAC/1.5 A at 400 VAC
      Lamp load (NO): 1.5 A at 125 VAC/1 A at 250 VAC/0.8 A at 400 VAC
      Inductive load: 10 A at 125 VAC/10 A at 250 VAC/3 A at 400 VAC
      Motor load (NC): 5 A at 125 VAC/3 A at 250 VAC/1.5 A at 400 VAC
      Motor load (NO): 2.5 A at 125 VAC/1.5 A at 250 VAC/0.8 A at 400 VAC
      Ratings (DC): Non-Inductive load Resistive load: 10 A at 8 VDC/10 A at 14 VDC/6 A at 30 VDC/0.8 A at 125 VDC/0.4 A at 250 VDC
      Lamp load (NC): 6 A at 8 VDC/6 A at 14 VDC/4 A at 30 VDC/0.2 A at 125 VDC/0.1 A at 250 VDC
      Lamp load (NO): 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/0.2 A at 125 VDC/0.1 A at 250 VDC
      Inductive load: 10 A at 8 VDC/10 A at 14 VDC/6 A at 30 VDC/0.8 A at 125 VDC/0.4 A at 250 VDC
      Motor load: 6 A at 8 VDC/6 A at 14 VDC/4 A at 30 VDC/0.2 A at 125 VDC/0.1 A at 250 VDC
      Inrush current 30 A max.
      Conduit G1/2 (PF1/2)
      Earth terminal With ground terminal
      Ambient temperature Operating: -40 to 80 ℃ (with no icing)
      Ambient humidity 95 %RH max.
      Permissible operating speed 1 mm/s to 0.5 m/s
      Permissible operating frequency Electrical: 30 operations / 1 minute max.
      Mechanical: 120 operations / 1 minute max.
      Contact resistance (Initial value) 25 mΩ max.
      Insulation resistance Between each terminal of the same polarities: 100 MΩ min.
      Between each terminal and non-live-metallic part: 100 MΩ min.
      at 500 VDC
      Impulse withstand voltage Between each terminal of the same polarities: 2.5 kV
      Between each terminaland ground: 4 kV
      Durability Electrical: 500,000 operations min. (10 A at 250 VAC)
      Mechanical: 30 million operations min.
      Vibration resistance Malfunction: 10 to 55 Hz, 0.75 mm single amplitude
      Shock resistance Destruction: 1000 m/s2 min.
      Malfunction: 300 m/s2 min.
      Degree of protection IP67
      Classification of protection against electric shock Class I (with ground terminal)
      Operating Force (OF) Standard value 18.63 N max.
      Release Force (RF) Standard value 1.96 N min.
      Pre-Travel (PT) Standard value 2 mm max.
      Movement Differential (MD) Standard value 1 mm max.
      Over-Travel (OT) Standard value 5 mm min.
      Operating Position (OP) Standard value 48±1 mm
      Total Travel (TT) Reference value 7 mm
      Free Position (FP) Standard value 51 mm max.
      Direct Opening Force Standard value 49.03 N min.
      Direct Opening Travel Standard value 3.2 mm min.