MODEL-OMRON E2E-X7D1-N-Z DC-NO TWO WIRE

Description

DELIVERY TIME : 1-2 WEEKS 

If you are looking for a proximity sensor, first form E2E. World-class performance/quality, wide variations allow you to choose the most suitable model according to your requirements.
Excellent environmental resistance is realized. The standard cable is oil resistant PVC. On sensing surface used strong material for cutting oil

  • Product Specification 
  • Part Numbers 
  • Catalog 

Proximity Sensors

Dimensional Drawing of OMRON Proximity Sensors

Pull-Out Cord Type OMRON Proximity Sensors (Shielded Type)

Pre-Wired Type OMRON Proximity Sensors (Non-Shielded Type)

Standard type proximity sensor E2E Pre-wired type (shielded type) outline drawing
Standard type proximity sensor E2E Pre-wired type (non-shielded type) outline drawing
*1.Vinyl insulated round cord φ4, 2-core (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.3mm) standard 2mVinyl
    insulated round cord φ4, 3-core (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.3mm) standard 2mBend-
    resistant cord type is
    vinyl insulated round cord φ4, 2-core (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.27mm) standard 2mVinyl
    insulated round cord φ4, 3-core (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.27mm) standard 2mOil-
    resistant reinforced cord type is
    polyurethane insulated round cord φ4, 2-core (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.3mm)
    standard 2mCord
    extension (single metal conduit) up to 200m
*2.D1 type: operation indicator (red), setting indicator (green), D2/E/F type: operation indicator (red)
* For information on model numbers other than those listed above, please refer to the digital catalog.
*1.Vinyl insulated round cord φ4, 2 cores (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.3mm) standard length
    2mVinyl insulated round cord φ4, 3 cores (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.3mm) standard length 2mFlexible
    cord type is
    vinyl insulated round cord φ4, 2 cores (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.27mm) standard length
    2mVinyl insulated round cord φ4, 3 cores (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.27mm) standard length 2mCord
    extension (single metal conduit) maximum 200m
*2.D1 type: operation indicator (red), setting indicator (green), D2/E/F types: operation indicator (red)
* For information on model numbers other than those mentioned above, please refer to the digital catalog.

Specification Table of OMRON Proximity Sensors

OMRON Proximity Sensors Ratings/Performance

Proximity Sensors DC 2-wire type (E2E-X□D□)

Proximity Sensors item size M8 M12 M18 M30
shield shield Unshielded shield Unshielded shield Unshielded shield Unshielded
Model number Model E2E-X2D□ Model E2E-X4MD□ Model E2E-X3D□ Model E2E-X8MD□ Model E2E-X7D□ Model E2E-X14MD□ Model E2E-X10D□ Model E2E-X20MD□
Proximity Sensors Detection distance 2mm±10% 4mm±10% 3mm±10% 8mm±10% 7mm±10% 14mm±10% 10mm±10% 20mm±10%
Set distance*1 0 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm
Hysteresis 15% or less of detection distance 10% or less of the detection distance
Detectable Objects Magnetic metal (non-magnetic metal reduces the detection distance.
Standard detection object Iron
8×8×1mm
Iron
20 x 20 x 1 mm
Iron
12 x 12 x 1 mm
Iron
30×30×1mm
Iron
18 x 18 x 1 mm
Iron
30×30×1mm
Iron
54×54×1mm
Response frequency*2 1.5kHz 1kHz 0.8kHz 0.5kHz 0.4kHz 0.1kHz
Power supply voltage
(operating voltage range)
Proximity Sensors Standard type: DC12 to 24V ripple (pp) 10% or less (DC10 to 30V)
When using US type or connector type as UL certified product: DC12 to 24V ripple (pp) 10% or less (usage voltage range is also the same)
Leakage current 0.8mA or less
Control
Output
Opening and closing capacity 3 to 100mA, diagnostic output 50mA [D1(5) S type only]
Residual voltage*3 3V or less (load current 100mA, cord length 2m, except M1J-T type only 5V or less)
Indicator Light D1 type: Operation indicator (red), setting indicator (green)
D2 type: Operation indicator (red)
Operation mode
(when detecting object approaching)
D1 type: NO
D2 type: NC
Diagnostic output delay time 0.3 to 1 s
Protection Circuit Surge absorption, load short circuit protection (both control output and diagnostic output)
Ambient Temperature Range Operating: -25 to +70°C Storage: -40 to +85°C (but do not freeze or condense)
Ambient Humidity Range During operation and storage: 35 to 95% RH (but no condensation)
Temperature effects Within ±15% of detection distance at +23°C within the temperature range of -25 to +70°C Within ±10% of detection distance at +23°C within the temperature range of -25 to +70°C
Voltage Effects Within ±1% of detection distance at rated power supply voltage within ±15% range
Insulation resistance 50MΩ or more (DC500V megger) between live parts and case
Withstand voltage AC1,000V 50/60Hz 1min Between live parts and case
Vibration (durability) 10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions
Impact (durability) 500m/s2 10 times each in X, Y, and Z directions 1,000m/s2 10 times each in X, Y, and Z directions
Protective structure Pre-wired type, connector relay type: IEC standard IP67
Connector type: IEC standard IP67
Connection method Pre-wired type (standard cord length 2m), connector type, relay connector type (standard cord length 300mm)
Weight
(packaged
)
Cord
pull-out type
Approx. 60g Approx. 70g Approx. 130g Approx. 175g
Connector
relay type
- Approx. 40g Approx. 70g Approx. 110g
Connector
Type
Approx. 15g Approx. 25g Approx. 40g Approx. 90g
Material case Stainless steel (SUS303) Brass, nickel plated
Detection surface PBT
Clamping Nut Brass, nickel plated
Toothed washer Iron Zinc plating
accessories operating instructions

*1. The Proximity Sensors Use within the range where the green indicator light is on. (Excluding D2 type)
*2. The response frequency of the Proximity Sensors is an average value.
   Measurement conditions are as follows: A standard detection object is used, the detection object interval is twice that of the standard detection object, and the set distance is 1/2 the detection distance.
*3. When using the M1J-T type, the residual voltage is 5V, so please check the interface conditions with the connected device before use.
* For information on model numbers other than those listed above, please refer to the digital catalog.

MODEL-OMRON E2E-X7D1-N-Z DC-NO TWO WIRE

Product form

DELIVERY TIME : 1-2 WEEKS  If you are looking for a proximity sensor, first form E2E. World-class performance/quality, wide variations... Read more

Rs. 6,136.00 Incl. VAT

      Description

      DELIVERY TIME : 1-2 WEEKS 

      If you are looking for a proximity sensor, first form E2E. World-class performance/quality, wide variations allow you to choose the most suitable model according to your requirements.
      Excellent environmental resistance is realized. The standard cable is oil resistant PVC. On sensing surface used strong material for cutting oil

      • Product Specification 
      • Part Numbers 
      • Catalog 

      Proximity Sensors

      Dimensional Drawing of OMRON Proximity Sensors

      Pull-Out Cord Type OMRON Proximity Sensors (Shielded Type)

      Pre-Wired Type OMRON Proximity Sensors (Non-Shielded Type)

      Standard type proximity sensor E2E Pre-wired type (shielded type) outline drawing
      Standard type proximity sensor E2E Pre-wired type (non-shielded type) outline drawing
      *1.Vinyl insulated round cord φ4, 2-core (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.3mm) standard 2mVinyl
          insulated round cord φ4, 3-core (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.3mm) standard 2mBend-
          resistant cord type is
          vinyl insulated round cord φ4, 2-core (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.27mm) standard 2mVinyl
          insulated round cord φ4, 3-core (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.27mm) standard 2mOil-
          resistant reinforced cord type is
          polyurethane insulated round cord φ4, 2-core (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.3mm)
          standard 2mCord
          extension (single metal conduit) up to 200m
      *2.D1 type: operation indicator (red), setting indicator (green), D2/E/F type: operation indicator (red)
      * For information on model numbers other than those listed above, please refer to the digital catalog.
      *1.Vinyl insulated round cord φ4, 2 cores (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.3mm) standard length
          2mVinyl insulated round cord φ4, 3 cores (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.3mm) standard length 2mFlexible
          cord type is
          vinyl insulated round cord φ4, 2 cores (conductor cross-sectional area: 0.3mm2, insulator diameter: φ1.27mm) standard length
          2mVinyl insulated round cord φ4, 3 cores (conductor cross-sectional area: 0.3mm2, Proximity Sensors insulator diameter: φ1.27mm) standard length 2mCord
          extension (single metal conduit) maximum 200m
      *2.D1 type: operation indicator (red), setting indicator (green), D2/E/F types: operation indicator (red)
      * For information on model numbers other than those mentioned above, please refer to the digital catalog.

      Specification Table of OMRON Proximity Sensors

      OMRON Proximity Sensors Ratings/Performance

      Proximity Sensors DC 2-wire type (E2E-X□D□)

      Proximity Sensors item size M8 M12 M18 M30
      shield shield Unshielded shield Unshielded shield Unshielded shield Unshielded
      Model number Model E2E-X2D□ Model E2E-X4MD□ Model E2E-X3D□ Model E2E-X8MD□ Model E2E-X7D□ Model E2E-X14MD□ Model E2E-X10D□ Model E2E-X20MD□
      Proximity Sensors Detection distance 2mm±10% 4mm±10% 3mm±10% 8mm±10% 7mm±10% 14mm±10% 10mm±10% 20mm±10%
      Set distance*1 0 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm
      Hysteresis 15% or less of detection distance 10% or less of the detection distance
      Detectable Objects Magnetic metal (non-magnetic metal reduces the detection distance.
      Standard detection object Iron
      8×8×1mm
      Iron
      20 x 20 x 1 mm
      Iron
      12 x 12 x 1 mm
      Iron
      30×30×1mm
      Iron
      18 x 18 x 1 mm
      Iron
      30×30×1mm
      Iron
      54×54×1mm
      Response frequency*2 1.5kHz 1kHz 0.8kHz 0.5kHz 0.4kHz 0.1kHz
      Power supply voltage
      (operating voltage range)
      Proximity Sensors Standard type: DC12 to 24V ripple (pp) 10% or less (DC10 to 30V)
      When using US type or connector type as UL certified product: DC12 to 24V ripple (pp) 10% or less (usage voltage range is also the same)
      Leakage current 0.8mA or less
      Control
      Output
      Opening and closing capacity 3 to 100mA, diagnostic output 50mA [D1(5) S type only]
      Residual voltage*3 3V or less (load current 100mA, cord length 2m, except M1J-T type only 5V or less)
      Indicator Light D1 type: Operation indicator (red), setting indicator (green)
      D2 type: Operation indicator (red)
      Operation mode
      (when detecting object approaching)
      D1 type: NO
      D2 type: NC
      Diagnostic output delay time 0.3 to 1 s
      Protection Circuit Surge absorption, load short circuit protection (both control output and diagnostic output)
      Ambient Temperature Range Operating: -25 to +70°C Storage: -40 to +85°C (but do not freeze or condense)
      Ambient Humidity Range During operation and storage: 35 to 95% RH (but no condensation)
      Temperature effects Within ±15% of detection distance at +23°C within the temperature range of -25 to +70°C Within ±10% of detection distance at +23°C within the temperature range of -25 to +70°C
      Voltage Effects Within ±1% of detection distance at rated power supply voltage within ±15% range
      Insulation resistance 50MΩ or more (DC500V megger) between live parts and case
      Withstand voltage AC1,000V 50/60Hz 1min Between live parts and case
      Vibration (durability) 10 to 55Hz, double amplitude 1.5mm, 2h each in X, Y, and Z directions
      Impact (durability) 500m/s2 10 times each in X, Y, and Z directions 1,000m/s2 10 times each in X, Y, and Z directions
      Protective structure Pre-wired type, connector relay type: IEC standard IP67
      Connector type: IEC standard IP67
      Connection method Pre-wired type (standard cord length 2m), connector type, relay connector type (standard cord length 300mm)
      Weight
      (packaged
      )
      Cord
      pull-out type
      Approx. 60g Approx. 70g Approx. 130g Approx. 175g
      Connector
      relay type
      - Approx. 40g Approx. 70g Approx. 110g
      Connector
      Type
      Approx. 15g Approx. 25g Approx. 40g Approx. 90g
      Material case Stainless steel (SUS303) Brass, nickel plated
      Detection surface PBT
      Clamping Nut Brass, nickel plated
      Toothed washer Iron Zinc plating
      accessories operating instructions

      *1. The Proximity Sensors Use within the range where the green indicator light is on. (Excluding D2 type)
      *2. The response frequency of the Proximity Sensors is an average value.
         Measurement conditions are as follows: A standard detection object is used, the detection object interval is twice that of the standard detection object, and the set distance is 1/2 the detection distance.
      *3. When using the M1J-T type, the residual voltage is 5V, so please check the interface conditions with the connected device before use.
      * For information on model numbers other than those listed above, please refer to the digital catalog.