MODEL-RELAY G7SA-5A-5A 18 MAKE OMRON 24VDC

Description

DELIVERY PERIOD : 1-2 WEEKS 

• Additional Push-In Plus terminal sockets are used to save wiring work in comparison with traditional screw terminals.
(Wiring time is reduced by 60%* in comparison with traditional screw terminals.)

• Relays with forcibly guided contacts (EN 61810-3, Certified by VDE).

• Supports the CE marking of machinery (Machinery Directive).

• Helps avoid hazardous machine status when used as part of an interlocking circuit.

• Four-pole and six-pole Relays are available.

• The Relay’s terminal arrangement simplifies PWB pattern design.

• Reinforced insulation between inputs and outputs. Reinforced insulation between some poles of different polarity.

* According to OMRON actual measurement data

Coil (4 poles)

 

Item Rated current (mA) Coil resistance (Ω) Max. voltage (V) Power consumption (mW)
Rated voltage
12 VDC 30 400 110% Approx. 360
18 VDC 20 900
21 VDC 17.1 1,225
24 VDC 15 1,600
48 VDC 7.5 6,400
110 VDC 3.8 28,810 Approx. 420

 

Coil (6 poles)

 

Item Rated current (mA) Coil resistance (Ω) Max. voltage (V) Power consumption (mW)
Rated voltage
12 VDC 41.7 288 110% Approx. 500
18 VDC 27.8 648
21 VDC 23.8 882
24 VDC 20.8 1,152
48 VDC 10.4 4,606
110 VDC 5.3 20,862 Approx. 580

 

Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
           2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.

Contacts

 

Load Resistive load
Rated load 6 A at 250 VAC, 6 A at 30 VDC
Rated carry current 6 A
Max. switching voltage 250 VAC, 125 VDC
Max. switching current 6 A
Contact materials Au plating + Ag alloy

 

Characteristics

Safety Relay Unit

 

Contact resistance *1 100 mΩ max.
Operating time *2 20 ms max.
Response time *3 10 ms max.
Release time *2 20 ms max.
Must operate voltage 75% max.
Must release voltage 10% min.
Maximum
operating
frequency
Mechanical 36,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *4 1,000 MΩ min.
Dielectric
Strength
*5 *6
Between coil
and contacts
4,000 VAC, 50/60 Hz for 1 min.
Between
contacts of
different olarity
4,000 VAC, 50/60 Hz for 1 min. (except for followings)
4 poles (for poles 3-4 in 4-pole Relays),
6 poles (for poles 3-5, 4-6, and 5-6 in 6-pole Relays): 2,500 VAC, 50/60 Hz for 1 min.
Between
contacts of the
same polarity
1,500 VAC, 50/60 Hz for 1 min.
Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 100 m/s2
Durability
*7
Mechanical 10,000,000 operations min. (at approx. 36,000 operations/h)
Electrical 100,000 operations min. (at the rated load)
Inductive load switching
capability *8
(IEC60947-5-1)
AC15 240 VAC, 2 A
DC13 24 VDC, 1 A/48 VDC, 0.5 A/110 VDC, 0.2 A
Failure rate (P level)
(reference value *9)
5 VDC, 1 mA
Ambient operating
temperature *10
12 to 48 VDC: -40 to 85°C (with no icing or condensation)
110 VDC: -40 to 60°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight 4 poles: Approx. 22 g
6 poles: Approx. 25 g

 

 

Note: 1. The above values are initial values.
           2. Performance characteristics are based on coil temparature of 23°C.
*1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
*2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not
       included.
*3. The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF.
       Contact bounce time is included. Measurement conditions: Rated voltage operation, Ambient temperature: 23°C
*4. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric
       strength was measured.
*5. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and
       pole 6 refers to terminals 63-64.
*6.When using a P7SA Socket, the dielectric strength between coil contacts/between contacts of different polarity is 2,500
  VAC, 50/60 Hz for 1 min. 
*7. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%. For the durability
       performance to the load, refer to the Durability Curve.
*8. AC15: cosφ = 0.3, DC13: L/R = 48-ms.
*9. The failure rate is based on an operating frequency of 300 operations/min.
*10. 12 to 48 VDC:
       When operating between 70 and 85°C, reduce the rated carry current of 6 A by 0.1 A for each degree above 70°C. 
  (See Fig. 1.)
       110 VDC:
       When operating between 40 and 60°C, reduce the rated carry current of 6 A by 0.27 A for each degree above 40°C. 
  (See Fig. 1.)

 

G7SA Specifications 10

Options (order separately)

Sockets

 

Model Push-In Plus terminals Screw terminals PCB terminals
4 poles 6 poles 4 poles 6 poles 4 poles 6 poles
P7SA-10F-ND-PU P7SA-14F-ND-PU P7SA-10F(-ND) P7SA-14F(-ND) P7SA-10P P7SA-14P
Ambient operating temperature P7SA-[]F-ND(-PU): -20 to +70°C
P7SA-[]F: -40 to +85°C
(with no icing or condensation)
-40 to +85°C
(with no icing or condensation)
Ambient operating humidity 25% to 85% 5% to 85%
Continuous carry current 6 A *1
Dielectric
strength
Between coil
and contact
terminals
4,000 VAC for 1 min. 2,500 VAC for 1 min.
Between contact
terminals of
different polarity
2,500 VAC for 1 min.
Between contact
terminals of
same polarity
1,500 VAC for 1 min.
Insulation resistance 1,000 MΩ min. *2
Weight Approx. 58 g Approx. 70 g Approx. 44 g Approx. 59 g Approx. 9 g Approx. 10 g

 

*1. When operating the P7SA-[]F-ND-PU at a temperature between 50 and 70°C, reduce the continuous current
       (6 A at 50°C or less) by 0.25 A for each degree above 50°C.
       When operating the P7SA-[]F-ND at a temperature between 50 and 70°C, reduce the continuous current
       (6 A at 50°C or less) by 0.3 A for each degree above 50°C.
       When operating the P7SA-[]F at a temperature between 50 and 85°C, reduce the continuous current
       (6 A at 50°C or less) by 0.1 A for each degree above 50°C.
*2. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.

Short Bars (for P7SA-[]F-ND-PU)

 

Application Applicable
sockets
Models Maximum
carry current
Ambient operating
temperature
Ambient operating
humidity
Crossover wiring of
contact terminals
(bottom)
P7SA-[]F-ND-PU XW5S-P2.5-2[] 24 A -40 to 55°C 5% to 95%
XW5S-P2.5-3[]
XW5S-P2.5-4[]
XW5S-P2.5-5[]

 

Certified Standards

Safety Relay Unit

EN Standards, VDE Certified

 

Models Ratings Standard number Certification No. Operating coil Contact ratings
G7SA-2A2B 12, 18, 21, 24, 48, 110 VDC EN/IEC 61810-1
Electromagnetic relay EN 61810-3
Relays with forcibly guided contacts
125547 12, 18, 21, 24, 48, 110 VDC 6 A, 240 VAC (Resistive)
6 A, 30 VDC (Resistive)
G7SA-3A1B
G7SA-3A3B
G7SA-4A2B
G7SA-5A1B

 

UL Standards Certification (File No. E41515) Industrial Control Devices

 

Models Category Listed/Recognized Contact ratings Operating Coil ratings
G7SA-2A2B E41515 Recognized 6 A, 250 VAC (Resistive)
6 A, 30 VDC (Resistive)
12, 18, 21, 24, 48, 110 VDC
G7SA-3A1B
G7SA-3A3B
G7SA-4A2B
G7SA-5A1B

 

CSA standard CSA C22.2 No.14 Industrial Control Devices

 

Models Class number File No. Contact ratings Operating Coil ratings
G7SA-2A2B 3211-07 LR35535 6 A, 250 VAC (Resistive)
6 A, 30 VDC (Resistive)
12, 18, 21, 24, 48, 110 VDC
G7SA-3A1B
G7SA-4A2B
G7SA-5A1B

 

South Korea S-mark certified (Rated voltage 24VDC only)

 

Models Applicable standard number
G7SA-2A2B DC24 KS C IEC 61810-1
G7SA-3A1B DC24
G7SA-3A3B DC24
G7SA-4A2B DC24
G7SA-5A1B DC24

 

CQC

 

Models Standard number Certification No.
G7SA GB/T, 21711.1 CQC14002119869

 

Sockets

CE Marking Compliance

 

Models EMC Directive Low Voltage Directive Machinery Directive
P7SA (Excluding -P type) Not applicable Applicable Not applicable
P7SA-PU Not applicable Applicable Not applicable

 

The CE compliance declaration was made in combination with the Safety Relay.

EN Standards, VDE Certified

 

Models Ratings Standard number Certification No.
P7SA --- EN61984 40007586

 

EN Standards, TÜV Certified

 

Models Ratings Standard number Certification No.
P7SA-PU --- EN61984 R50356981

 

UL Standards Certification (File No. E87929) Industrial Control Devices

 

Models Category Listed/Recognized
P7SA SWIV2 Recognized
P7SA-PU SWIV2, SWIV8 Recognized

 

CSA standard CSA C22.2 No.14 Industrial Control Devices

 

Models Class number File No.
P7SA 3211-07, 3211-87 LR35535
P7SA-PU 3211-07, 3211-87 LR35535

 

MODEL-RELAY G7SA-5A-5A 18 MAKE OMRON 24VDC

Product form

DELIVERY PERIOD : 1-2 WEEKS  • Additional Push-In Plus terminal sockets are used to save wiring work in comparison with... Read more

Rs. 1,416.00 Incl. VAT

      Description

      DELIVERY PERIOD : 1-2 WEEKS 

      • Additional Push-In Plus terminal sockets are used to save wiring work in comparison with traditional screw terminals.
      (Wiring time is reduced by 60%* in comparison with traditional screw terminals.)

      • Relays with forcibly guided contacts (EN 61810-3, Certified by VDE).

      • Supports the CE marking of machinery (Machinery Directive).

      • Helps avoid hazardous machine status when used as part of an interlocking circuit.

      • Four-pole and six-pole Relays are available.

      • The Relay’s terminal arrangement simplifies PWB pattern design.

      • Reinforced insulation between inputs and outputs. Reinforced insulation between some poles of different polarity.

      * According to OMRON actual measurement data

      Coil (4 poles)

       

      Item Rated current (mA) Coil resistance (Ω) Max. voltage (V) Power consumption (mW)
      Rated voltage
      12 VDC 30 400 110% Approx. 360
      18 VDC 20 900
      21 VDC 17.1 1,225
      24 VDC 15 1,600
      48 VDC 7.5 6,400
      110 VDC 3.8 28,810 Approx. 420

       

      Coil (6 poles)

       

      Item Rated current (mA) Coil resistance (Ω) Max. voltage (V) Power consumption (mW)
      Rated voltage
      12 VDC 41.7 288 110% Approx. 500
      18 VDC 27.8 648
      21 VDC 23.8 882
      24 VDC 20.8 1,152
      48 VDC 10.4 4,606
      110 VDC 5.3 20,862 Approx. 580

       

      Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
                 2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.

      Contacts

       

      Load Resistive load
      Rated load 6 A at 250 VAC, 6 A at 30 VDC
      Rated carry current 6 A
      Max. switching voltage 250 VAC, 125 VDC
      Max. switching current 6 A
      Contact materials Au plating + Ag alloy

       

      Characteristics

      Safety Relay Unit

       

      Contact resistance *1 100 mΩ max.
      Operating time *2 20 ms max.
      Response time *3 10 ms max.
      Release time *2 20 ms max.
      Must operate voltage 75% max.
      Must release voltage 10% min.
      Maximum
      operating
      frequency
      Mechanical 36,000 operations/h
      Rated load 1,800 operations/h
      Insulation resistance *4 1,000 MΩ min.
      Dielectric
      Strength
      *5 *6
      Between coil
      and contacts
      4,000 VAC, 50/60 Hz for 1 min.
      Between
      contacts of
      different olarity
      4,000 VAC, 50/60 Hz for 1 min. (except for followings)
      4 poles (for poles 3-4 in 4-pole Relays),
      6 poles (for poles 3-5, 4-6, and 5-6 in 6-pole Relays): 2,500 VAC, 50/60 Hz for 1 min.
      Between
      contacts of the
      same polarity
      1,500 VAC, 50/60 Hz for 1 min.
      Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
      Shock
      resistance
      Destruction 1,000 m/s2
      Malfunction 100 m/s2
      Durability
      *7
      Mechanical 10,000,000 operations min. (at approx. 36,000 operations/h)
      Electrical 100,000 operations min. (at the rated load)
      Inductive load switching
      capability *8
      (IEC60947-5-1)
      AC15 240 VAC, 2 A
      DC13 24 VDC, 1 A/48 VDC, 0.5 A/110 VDC, 0.2 A
      Failure rate (P level)
      (reference value *9)
      5 VDC, 1 mA
      Ambient operating
      temperature *10
      12 to 48 VDC: -40 to 85°C (with no icing or condensation)
      110 VDC: -40 to 60°C (with no icing or condensation)
      Ambient operating humidity 5% to 85%
      Weight 4 poles: Approx. 22 g
      6 poles: Approx. 25 g

       

       

      Note: 1. The above values are initial values.
                 2. Performance characteristics are based on coil temparature of 23°C.
      *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
      *2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not
             included.
      *3. The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF.
             Contact bounce time is included. Measurement conditions: Rated voltage operation, Ambient temperature: 23°C
      *4. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric
             strength was measured.
      *5. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and
             pole 6 refers to terminals 63-64.
      *6.When using a P7SA Socket, the dielectric strength between coil contacts/between contacts of different polarity is 2,500
        VAC, 50/60 Hz for 1 min. 
      *7. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%. For the durability
             performance to the load, refer to the Durability Curve.
      *8. AC15: cosφ = 0.3, DC13: L/R = 48-ms.
      *9. The failure rate is based on an operating frequency of 300 operations/min.
      *10. 12 to 48 VDC:
             When operating between 70 and 85°C, reduce the rated carry current of 6 A by 0.1 A for each degree above 70°C. 
        (See Fig. 1.)
             110 VDC:
             When operating between 40 and 60°C, reduce the rated carry current of 6 A by 0.27 A for each degree above 40°C. 
        (See Fig. 1.)

       

      G7SA Specifications 10

      Options (order separately)

      Sockets

       

      Model Push-In Plus terminals Screw terminals PCB terminals
      4 poles 6 poles 4 poles 6 poles 4 poles 6 poles
      P7SA-10F-ND-PU P7SA-14F-ND-PU P7SA-10F(-ND) P7SA-14F(-ND) P7SA-10P P7SA-14P
      Ambient operating temperature P7SA-[]F-ND(-PU): -20 to +70°C
      P7SA-[]F: -40 to +85°C
      (with no icing or condensation)
      -40 to +85°C
      (with no icing or condensation)
      Ambient operating humidity 25% to 85% 5% to 85%
      Continuous carry current 6 A *1
      Dielectric
      strength
      Between coil
      and contact
      terminals
      4,000 VAC for 1 min. 2,500 VAC for 1 min.
      Between contact
      terminals of
      different polarity
      2,500 VAC for 1 min.
      Between contact
      terminals of
      same polarity
      1,500 VAC for 1 min.
      Insulation resistance 1,000 MΩ min. *2
      Weight Approx. 58 g Approx. 70 g Approx. 44 g Approx. 59 g Approx. 9 g Approx. 10 g

       

      *1. When operating the P7SA-[]F-ND-PU at a temperature between 50 and 70°C, reduce the continuous current
             (6 A at 50°C or less) by 0.25 A for each degree above 50°C.
             When operating the P7SA-[]F-ND at a temperature between 50 and 70°C, reduce the continuous current
             (6 A at 50°C or less) by 0.3 A for each degree above 50°C.
             When operating the P7SA-[]F at a temperature between 50 and 85°C, reduce the continuous current
             (6 A at 50°C or less) by 0.1 A for each degree above 50°C.
      *2. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.

      Short Bars (for P7SA-[]F-ND-PU)

       

      Application Applicable
      sockets
      Models Maximum
      carry current
      Ambient operating
      temperature
      Ambient operating
      humidity
      Crossover wiring of
      contact terminals
      (bottom)
      P7SA-[]F-ND-PU XW5S-P2.5-2[] 24 A -40 to 55°C 5% to 95%
      XW5S-P2.5-3[]
      XW5S-P2.5-4[]
      XW5S-P2.5-5[]

       

      Certified Standards

      Safety Relay Unit

      EN Standards, VDE Certified

       

      Models Ratings Standard number Certification No. Operating coil Contact ratings
      G7SA-2A2B 12, 18, 21, 24, 48, 110 VDC EN/IEC 61810-1
      Electromagnetic relay EN 61810-3
      Relays with forcibly guided contacts
      125547 12, 18, 21, 24, 48, 110 VDC 6 A, 240 VAC (Resistive)
      6 A, 30 VDC (Resistive)
      G7SA-3A1B
      G7SA-3A3B
      G7SA-4A2B
      G7SA-5A1B

       

      UL Standards Certification (File No. E41515) Industrial Control Devices

       

      Models Category Listed/Recognized Contact ratings Operating Coil ratings
      G7SA-2A2B E41515 Recognized 6 A, 250 VAC (Resistive)
      6 A, 30 VDC (Resistive)
      12, 18, 21, 24, 48, 110 VDC
      G7SA-3A1B
      G7SA-3A3B
      G7SA-4A2B
      G7SA-5A1B

       

      CSA standard CSA C22.2 No.14 Industrial Control Devices

       

      Models Class number File No. Contact ratings Operating Coil ratings
      G7SA-2A2B 3211-07 LR35535 6 A, 250 VAC (Resistive)
      6 A, 30 VDC (Resistive)
      12, 18, 21, 24, 48, 110 VDC
      G7SA-3A1B
      G7SA-4A2B
      G7SA-5A1B

       

      South Korea S-mark certified (Rated voltage 24VDC only)

       

      Models Applicable standard number
      G7SA-2A2B DC24 KS C IEC 61810-1
      G7SA-3A1B DC24
      G7SA-3A3B DC24
      G7SA-4A2B DC24
      G7SA-5A1B DC24

       

      CQC

       

      Models Standard number Certification No.
      G7SA GB/T, 21711.1 CQC14002119869

       

      Sockets

      CE Marking Compliance

       

      Models EMC Directive Low Voltage Directive Machinery Directive
      P7SA (Excluding -P type) Not applicable Applicable Not applicable
      P7SA-PU Not applicable Applicable Not applicable

       

      The CE compliance declaration was made in combination with the Safety Relay.

      EN Standards, VDE Certified

       

      Models Ratings Standard number Certification No.
      P7SA --- EN61984 40007586

       

      EN Standards, TÜV Certified

       

      Models Ratings Standard number Certification No.
      P7SA-PU --- EN61984 R50356981

       

      UL Standards Certification (File No. E87929) Industrial Control Devices

       

      Models Category Listed/Recognized
      P7SA SWIV2 Recognized
      P7SA-PU SWIV2, SWIV8 Recognized

       

      CSA standard CSA C22.2 No.14 Industrial Control Devices

       

      Models Class number File No.
      P7SA 3211-07, 3211-87 LR35535
      P7SA-PU 3211-07, 3211-87 LR35535

       