MODEL-TENSION CONTROLLER , MAKE MITSUBISHI MODEL-LE -40MTB-E

Description

DELIVERY PERIOD : 1-2 WEEKS 

Mitsubishi Tension Controller LE-30CTA
The DC input Input channel number: 2CH DC5/12/24 v input Maximum counting speed: 200K Pulse /s Linear counter function Ring counter function Consistent output function The default function Invalid count function Latch counter function Sampling counter function Periodic pulse counter function Flexible application for various purposes, through the combination of functions, easy to achieve speed measurement, measurement function, single pulse output, ratio setting/distribution output, PWM control, CAM switch control and other extensive control LE-30CTA.

1. The switching quantity acquisition and switching control and the RS-485 bus are completely isolated from each other and isolated from the whole system. 2. The power cable has anti-reverse connection function. Once the wrong power cable is connected, the power will be automatically cut off to protect the entire module from damage. With overvoltage protection, when the voltage is too high, the automatic disconnection protects the entire module from damage. 3, RS-485 interface has 600W lightning protection and surge protection, with 3000V optical isolation. 4, using Modbus protocol, good versatility, can be easily connected with other systems, customers can also customize the relevant protocols according to their individual needs, convenient and flexible. 5. The communication line adopts RS-485 bus, which supports multiple modules to be used in parallel to expand the system, and has good scalability. Number of output points: 16 points. Output form: bidirectional thyristor output. Rated output voltage: AC100 ~ 240V. Maximum load current: 0.6A/1 point. Public mode: 16 points / public. Input and output occupied points: 16 points (I/O allocation: output 16 points). External wiring connection: 18-point terminal block. 1. The switch quantity acquisition and open day control are completely isolated from the RS-485 bus and isolated from the whole system. 2. The power cable has anti-reverse connection function. Once the wrong power cable is connected, the power will be automatically cut off to protect the entire module from damage.

MODEL-TENSION CONTROLLER , MAKE MITSUBISHI MODEL-LE -40MTB-E

Product form

DELIVERY PERIOD : 1-2 WEEKS  Mitsubishi Tension Controller LE-30CTA The DC input Input channel number: 2CH DC5/12/24 v input Maximum... Read more

Rs. 171,100.00 Excl. VAT

  • Shipped today? Order within: Jul 19, 2025 17:00:00 -0400

    Description

    DELIVERY PERIOD : 1-2 WEEKS 

    Mitsubishi Tension Controller LE-30CTA
    The DC input Input channel number: 2CH DC5/12/24 v input Maximum counting speed: 200K Pulse /s Linear counter function Ring counter function Consistent output function The default function Invalid count function Latch counter function Sampling counter function Periodic pulse counter function Flexible application for various purposes, through the combination of functions, easy to achieve speed measurement, measurement function, single pulse output, ratio setting/distribution output, PWM control, CAM switch control and other extensive control LE-30CTA.

    1. The switching quantity acquisition and switching control and the RS-485 bus are completely isolated from each other and isolated from the whole system. 2. The power cable has anti-reverse connection function. Once the wrong power cable is connected, the power will be automatically cut off to protect the entire module from damage. With overvoltage protection, when the voltage is too high, the automatic disconnection protects the entire module from damage. 3, RS-485 interface has 600W lightning protection and surge protection, with 3000V optical isolation. 4, using Modbus protocol, good versatility, can be easily connected with other systems, customers can also customize the relevant protocols according to their individual needs, convenient and flexible. 5. The communication line adopts RS-485 bus, which supports multiple modules to be used in parallel to expand the system, and has good scalability. Number of output points: 16 points. Output form: bidirectional thyristor output. Rated output voltage: AC100 ~ 240V. Maximum load current: 0.6A/1 point. Public mode: 16 points / public. Input and output occupied points: 16 points (I/O allocation: output 16 points). External wiring connection: 18-point terminal block. 1. The switch quantity acquisition and open day control are completely isolated from the RS-485 bus and isolated from the whole system. 2. The power cable has anti-reverse connection function. Once the wrong power cable is connected, the power will be automatically cut off to protect the entire module from damage.

    Recently viewed products

    Login

    Forgot your password?

    Don't have an account yet?
    Create account