Power rating
Item Output voltage
|
50 W
|
5 V
|
12 V
|
15 V
|
24 V
|
48 V
|
Efficiency *
|
115 VAC input
|
79% typ.
|
83% typ.
|
84% typ.
|
86% typ.
|
87% typ.
|
230 VAC input
|
80% typ.
|
84% typ.
|
85% typ.
|
86% typ.
|
87% typ.
|
Input
|
Voltage range *
|
Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.)
|
Frequency *
|
50 /60 Hz (47 to 450 Hz)
|
Current *
|
115 VAC input
|
0.97 A typ.
|
230 VAC input
|
0.59 A typ.
|
Power factor
|
---
|
Leakage current
|
115 VAC input
|
0.25 mA
|
0.25 mA
|
0.25 mA
|
0.25 mA
|
0.25 mA
|
230 VAC input
|
0.60 mA
|
0.55 mA
|
0.55 mA
|
0.55 mA
|
0.55 mA
|
Inrush current *
(for a cold start at 25°)
|
115 VAC input
|
16 A typ.
|
230 VAC input
|
32 A typ.
|
Output
|
Rated Output Current
|
10 A
|
4.2 A
|
3.4 A
|
2.2 A
|
1.1 A
|
Voltage adjustment range *
|
-10% to 10% (with V. ADJ)
|
Ripple & Noise voltage *
|
100 to 240 VAC
input
|
80 mVp-p max.
|
110 mVp-p max.
|
100 mVp-p max.
|
100 mVp-p max.
|
120 mVp-p max.
|
Input variation influence *
|
0.5% max.
|
Load variation influence *
|
1.0% max.
|
Temperature vari- ation influence
|
100 to 240 VAC
input
|
0.03%/°C max.
|
Startup time *
|
115 VAC input
|
730 ms typ.
|
730 ms typ.
|
710 ms typ.
|
710 ms typ.
|
770 ms typ.
|
230 VAC input
|
680 ms typ.
|
670 ms typ.
|
610 ms typ.
|
640 ms typ.
|
690 ms typ.
|
Hold time *
|
115 VAC input
|
12 ms typ.
|
14 ms typ.
|
14 ms typ.
|
14 ms typ.
|
14 ms typ.
|
230 VAC input
|
71 ms typ.
|
77 ms typ.
|
78 ms typ.
|
77 ms typ.
|
80 ms typ.
|
Addi- tional func- tions
|
Overload protection
|
Yes, automatic reset
|
Overvoltage protection *
|
Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)
|
Overheat protection
|
No
|
Series operation
|
Yes (For up to 2 Power Supplies, external diodes are required.)
|
Parallel operation
|
No (However, backup operation is possible, external diodes are required.)
|
Remote sensing
|
No
|
Remote control
|
No
|
Output indicator
|
Yes (LED: Green)
|
Insula- tion
|
Withstand voltage
|
3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA
|
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA
|
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA
|
Insulation resistance
|
100 MÙ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC
|
Envi- ronment
|
Ambient operating temperature
|
-20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing)
|
Storage temperature
|
-40 to 85°C (with no condensation or icing)
|
Ambient operating humidity
|
20% to 90% (Storage humidity: 10% to 95%)
|
Vibration resistance
|
10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions
|
Shock resistance
|
150 m/s2, 3 times each in ±X, ±Y, ±Z directions
|
Reliabil- ity
|
MTBF
|
135,000 hrs min.
|
Life expectancy *
|
10 years min.
|
Con- struc- tion
|
Dimensions (W´H´D)
|
Refer to Dimensions on pages 20 and 24.
|
Weight
|
300 g max.
|
Cooling fan
|
No
|
Degree of protection
|
---
|
Stan- dards
|
Harmonic current emissions
|
Conforms to EN 61000-3-2, GB17625.1
|
EMI
|
Conducted Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254
|
Radiated Emissions
|
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254
|
EMS
|
Conforms to EN 61204-3 high severity levels
|
Safety Standards
|
Approved Standards
UL : cURus UL 60950-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No60950-1
CCC: GB4943
Conformed Standards
EN: EN 60950-1 OVC II Pol2
|
Marine Standards
|
No
|
SEMI
|
No
|