Degree of protection |
IP67 |
Durability *1 |
Mechanical |
10,000,000 operations min. |
Electrical |
5,000,000 operations min. (at 30 mA 30 VDC resistive load) |
Operating speed |
5 to 500 mm/s |
Operating frequency |
Mechanical |
120 operations/min. |
Electrical |
60 operations/min. |
Insulation resistance |
100 MΩ min. at 250 VDC between each terminal and non-current-carrying metal parts |
Contact resistance |
With 1 m cable:700 mΩ max. (initial value) With 3 m cable:1.9 Ω max. (initial value) With 5 m cable:3.1 Ω max. (initial value) |
Dielectric strength (50/60 Hz 1 min) |
Between terminals of same polarity |
250 VAC (at TTP) |
Between each terminal and non-current- carrying metal parts |
1,000 VAC (600 VAC for M5 model) |
Vibration resistance |
Malfunction |
10 to 55 Hz, 1.5-mm double amplitude *2 |
Shock resistance |
Mechanical |
1,000 m/s2 max. |
Malfunction |
300 m/s2 max. *3 |
Ambient operating temperature |
-10°C to +70°C (with no icing) |
Ambient operating humidity |
35% to 95% RH |
Actuator strength |
14.7 N *4 |
Weight |
Switch |
M5: Approx. 14 g, M8: Approx. 20 g, M10: Approx. 21 g |
Cable |
Approx. 10 g/m |