Rated power supply voltage 24 VDC If power supply incorporates a single-phase full-wave rectifier.
Allowable voltage variable range 85 to 110% of the power supply voltage
Power consumption Relay ON: Approx. 1.1 W (at 24 VDC)/Relay OFF: Approx. 0.1 W (at 24 VDC)
Reset voltage 10% max. of rated supply voltage
Number of time ranges 4
Operation mode ON delay, Interval, Flicker OFF start, Flicker ON start
Control output (Type) Time-limit: 4PDT
Control output (Contact output) Resistive load: 3 A at 250 VAC (cosφ=1)
Minimum applicable load: 1 mA at 1 VDC (failure level: P)
Ambient temperature range Operating: -10 to 50 ℃ (with no icing)
Storage: -25 to 65 ℃ (with no icing)
Ambient humidity range Operating: 35 to 85 %
Accuracy of operating time ±1% FS max. (±1% ±10 ms in a range of 1 s)
Setting error ±10% FS ±50 ms max.
Reset time 0.1 s max. (including halfway reset)
Influence of voltage ±2% FS max.
Influence of temperature ±2% FS max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength Between current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min (Terminal screw sections are not excluded)
Between operating power circuit and control output: 2,000 VAC 50/60 Hz 1 min
Between contacts of different polarity: 1,500 VAC 50/60 Hz 1 min
Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Impulse withstand voltage Between power terminals: 1 kV
Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV
Noise immunity ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity Mulfunction: 4 kV, Destruction: 8 kV
Vibration resistance Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour
Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistance Destruction: 1,000 m/s2, 3 times each in 6 directions
Malfunction: 100 m/s2, 3 times each in 6 directions
Life expectancy (relay output) Electrical: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h, Room temperature)
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Degree of protection IP40
Connecting method 14-pin round socket
Case color Beige
Weight Approx. 50 g
Applicable socket PYFZ-14/ PYFZ-14-E/ PY14/ PY14-02

TIMER OMRON H3YN-4 MAKE OMRON

Product form

DELIVERY PERIOD : 1-2 WEEKS  Rated power supply voltage 24 VDC If power supply incorporates a single-phase full-wave rectifier. Allowable... Read more

Rs. 5,222.00 Rs. 3,080.98 Incl. VAT

  • Shipped today? Order within: Sep 29, 2025 17:00:00 -0400

    Description

    DELIVERY PERIOD : 1-2 WEEKS 

    Rated power supply voltage 24 VDC If power supply incorporates a single-phase full-wave rectifier.
    Allowable voltage variable range 85 to 110% of the power supply voltage
    Power consumption Relay ON: Approx. 1.1 W (at 24 VDC)/Relay OFF: Approx. 0.1 W (at 24 VDC)
    Reset voltage 10% max. of rated supply voltage
    Number of time ranges 4
    Operation mode ON delay, Interval, Flicker OFF start, Flicker ON start
    Control output (Type) Time-limit: 4PDT
    Control output (Contact output) Resistive load: 3 A at 250 VAC (cosφ=1)
    Minimum applicable load: 1 mA at 1 VDC (failure level: P)
    Ambient temperature range Operating: -10 to 50 ℃ (with no icing)
    Storage: -25 to 65 ℃ (with no icing)
    Ambient humidity range Operating: 35 to 85 %
    Accuracy of operating time ±1% FS max. (±1% ±10 ms in a range of 1 s)
    Setting error ±10% FS ±50 ms max.
    Reset time 0.1 s max. (including halfway reset)
    Influence of voltage ±2% FS max.
    Influence of temperature ±2% FS max.
    Insulation resistance 100 MΩ min. (at 500 VDC)
    Dielectric strength Between current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min (Terminal screw sections are not excluded)
    Between operating power circuit and control output: 2,000 VAC 50/60 Hz 1 min
    Between contacts of different polarity: 1,500 VAC 50/60 Hz 1 min
    Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
    Impulse withstand voltage Between power terminals: 1 kV
    Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV
    Noise immunity ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
    Static immunity Mulfunction: 4 kV, Destruction: 8 kV
    Vibration resistance Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour
    Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
    Shock resistance Destruction: 1,000 m/s2, 3 times each in 6 directions
    Malfunction: 100 m/s2, 3 times each in 6 directions
    Life expectancy (relay output) Electrical: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h, Room temperature)
    Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
    Degree of protection IP40
    Connecting method 14-pin round socket
    Case color Beige
    Weight Approx. 50 g
    Applicable socket PYFZ-14/ PYFZ-14-E/ PY14/ PY14-02