Omron

516 products

  • MODEL-EXPANSION MODULE CP1W-40EDT MAKE OMRON

    MODEL-EXPANSION MODULE CP1W-40EDT MAKE OMRON

    DELIVERY TIME : 1-2 WEEKS  ype of module Digital I/O Number of digital inputs 24 Digital input type PNP/NPN OFF/ON delay 0.1-1 ms Permitted voltage at input 20.4-26.4 V Number of digital outputs 16 Digital output type NPN Output current 0.3 A Permitted voltage at output 4.5-30 V Product Height (unpacked) 90 mm Product Width (unpacked) 150 mm Product Depth (unpacked) 50 mm Product Weight (unpacked) 320 g

    Rs. 12,200.00

  • MODEL-LOCK PIN D4DS-K2 OMRON

    MODEL-LOCK PIN D4DS-K2 OMRON

    DELIVERY TIME : 1-2 WEEKS  Type Description Select All Category Switches Accessories  Manufacturer Omron Automation and Safety Series D4NS Packaging Bulk Part Status Active Accessory Type Operation Key For Use With/Related Products D4NS Series Report Product Information Error View Similar

    Rs. 260.80

  • MODEL-LOCK PIN D4DS-K1 OMRON

    MODEL-LOCK PIN D4DS-K1 OMRON

    DELIVERY TIME : 1-2 WEEKS  Type Description Select All Category Switches Accessories Manufacturer Omron Automation and Safety Series D4NS Packaging Bulk Part Status Active Accessory Type Operation Key For Use With/Related Products D4NS Series

    Rs. 260.80

  • MODEL-SSR G3NE-205TL-US MAKE OMRON

    MODEL-SSR G3NE-205TL-US MAKE OMRON

    DELIVERY TIME : 1-2 WEEKS  Solid State Relay, Phototriac, Applied output load: 5 A at 100 to 240 VAC, Without Zero cross function, #110 input terminals, Certified by UL, CSA, and EN (TUV), Rated input voltage: 24 VDC Product classification For single-phase heater Zero cross function None Operating indicator None Rated voltage 24 VDC Rated load voltage 100 to 240 VAC Load current 0.1 to 5 A (With heat sink at 40 ℃)0.1 to 5 A (Without a heat sink at 40 ℃) Terminal structure Tab terminal (Input: #110, Output: #250)

    Rs. 1,500.00

  • MODEL-MY2N-GS-R RELAY 24VDC MAKE OMRON

    MODEL-MY2N-GS-R RELAY 24VDC MAKE OMRON

    DELIVERY TIME : 1-2 WEEKS  [Features]· Lead-use eliminated, safe for environment.·With different colors for AC and DC coil tapes, AC and DC specifications are easily identified.·Type MY(S) with a convenient latching lever for circuit check is now also available.·Wiring labor-hours can be shortened by 60% if combined with push-in plus socket Type PYF-□-PU (according to the manufacturer's measured data).·Terminal Shape: Socket / plug-in terminal, PCB terminal.[Applications]·Widely applicable to almost all types of electrical machines and devices.

    Rs. 124.72

  • MODEL-MY4N-GS RELAY 24VDC MAKE OMRON

    MODEL-MY4N-GS RELAY 24VDC MAKE OMRON

    DELIVERY TIME : 1-2 WEEKS  Operating indicator LED Degree of protection Closed type (cover) Terminal structure Plug-in terminal Coil Coil ratings 24 VDC 36.3 mA Coil resistance 662 Ω Operate voltage (Set voltage) 80 % max. Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % (23 ℃) Power consumption Approx. 0.9 W Contact Contact rated load 220 VAC 3 A (Resistive load)220 VAC 0.8 A (Inductive load (cosφ = 0.4))24 VDC 3 A (Resistive load)24 VDC 1.5 A (Inductive load (L/R = 7 ms)) Max. contact voltage 250 VAC125 VDC Max. contact current AC: 3 ADC: 3 A Maximum switching power 660 VA (Resistive load)176 VA (Inductive load (cosφ = 0.4))72 W (Resistive load)36 W (Inductive load (L/R = 7 ms)) Contact form 4PDT Contact method Single Contact material Au clad + Ag alloy Performance Contact resistance 50 mΩ max. (Voltage drop method with 5 VDC 1 A) Operating time 20 ms max. (With rated operating power applied, not including contact bounce) Reset time 20 ms max. (With rated operating power applied, not including contact bounce) Maximum operating frequency Mechanical: 18000 time/hourRated load: 1800 time/hour Insulation resistance Between coil and contacts: 100 MΩ min. (at 500 VDC)Between contacts of different polarity: 100 MΩ min. (at 500 VDC)Between contacts of same polarity: 100 MΩ min. (at 500 VDC) Dielectric strength Between coil and contacts: 2000 VAC 50/60 Hz 1 minBetween contacts of different polarity: 2000 VAC 50/60 Hz 1 minBetween contacts of same polarity: 1000 VAC 50/60 Hz 1 min Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude) Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude) Shock resistance (destruction) 1000 m/s2 Shock resistance (Malfunction) 200 m/s2 Endurance (Mechanical) 100 million operations min. (switching frequency 18,000 operations/h) Endurance (Electrical) 200,000 operations min. (23 ℃, Rated load, switching frequency 1,800 operations/h) Failure rate 1 VDC 1 mA (failure level: Preference value, Switching frequency: 120 operations per minute) Ambient temperature (Operating) -55 to 60 ℃ (with no freezing or condensation) Ambient humidity (Operating) 5 to 85 % Weight Approx. 35 g Mounting method Socket Applicable socket PYF14S/ PYF14T/ PYF-14-PU/ PYF-14-PU-L/ PYFZ-14/ PYFZ-14-E/ PY14/ PY14-Y1/ PY14QN/ PY14QN2/ PY14QN-Y1/ PY14QN2-Y1/ PY14-02

    Rs. 618.24

  • MODEL-PHOTO SENSOR E3JK-R4M1 OMRON FOR ST CONVEYOR

    MODEL-PHOTO SENSOR E3JK-R4M1 OMRON FOR ST CONVEYOR

    DELIVERY TIME : 1-2 WEEKS  Specification Value Sensing Method Retroreflective Sensing Distance 4 m Light Source Red LED Power Supply Voltage 50/60 Hz 12 to 240 VDC ±10%, 24 to 240 VAC ±10 Current Consumption 2 W max. Control Output Relay output: 3 A max. at 250 VAC (cosφ = 1), 10 mA min. at 5 VDC Operation Mode Light-ON mode Response Time 30 ms max. Sensitivity Adjustment Fixed Indicators Light (red) Ambient Temperature Range Operating: –25°C to 55°C (with no icing) Material Plastic The Omron E3JK-R4M1 is a reliable retroreflective photoelectric sensor built for long-distance object detection in general industrial environments. With a sensing range of up to 4 meters, this sensor uses a red LED light source and operates in conjunction with a reflector to detect the presence or absence of objects accurately. It is ideal for applications such as pallet detection, carton counting, and conveyor automation. This sensor supports dual power input: 12 to 240 VDC and 24 to 240 VAC (±10%), allowing flexible installation in both AC and DC systems. The E3JK-R4M1 provides a relay output capable of switching up to 3 A at 250 VAC (cosφ = 1), with a minimum switching capacity of 10 mA at 5 VDC. The sensor operates in Light-ON mode and features a fixed sensitivity setting with a fast 30 ms maximum response time, suitable for moderate-speed automation processes. Power consumption is limited to 2 W max., making it energy-efficient in continuous operation. The red LED status indicator offers clear visibility of sensor activity. Although sensitivity is fixed, the sensor provides reliable performance across a variety of materials and surface finishes when properly aligned with its retroreflective target. The housing is made of durable plastic, and the sensor functions reliably within an ambient temperature range of −25°C to 55°C. It includes essential protections such as insulation resistance, dielectric strength, and tolerance to vibration and shock, ensuring durability in active production environments. With a design focused on simplicity and ruggedness, the Omron E3JK-R4M1 is ideal for OEMs, maintenance engineers, and system integrators looking for dependable long-range sensing in space-efficient form factors.

    Rs. 1,350.00

  • MODEL-LIMIT SWITCH D4MC-2000 OMRON

    MODEL-LIMIT SWITCH D4MC-2000 OMRON

    DELIVERY TIME : 1-2 WEEKS  Shape/Structure Enclosed Limit switches ctuator Hinge roller lever 12.7 dia. x 7.5 Frequency 50/60 Hz Contact form SPDT Load General load Ratings (AC): Non-Inductive load Resistive load: 10 A at 125 VAC/10 A at 250 VAC/3 A at 480 VACLamp load (NC): 3 A at 125 VAC/2.5 A at 250 VAC/1.5 A at 480 VACLamp load (NO): 1.5 A at 125 VAC/1.25 A at 250 VAC/0.75 A at 480 VACInductive load: 10 A at 125 VAC/10 A at 250 VAC/2.5 A at 480 VACMotor load (NC): 5 A at 125 VAC/3 A at 250 VAC/1.5 A at 480 VACMotor load (NO): 2.5 A at 125 VAC/1.5 A at 250 VAC/0.75 A at 480 VAC Ratings (DC): Non-Inductive load Resistive load: 10 A at 8 VDC/10 A at 14 VDC/6 A at 30 VDC/0.5 A at 125 VDC/0.25 A at 250 VDCLamp load (NC): 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDCLamp load (NO): 1.5 A at 8 VDC/1.5 A at 14 VDC/1.5 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDCInductive load: 6 A at 8 VDC/6 A at 14 VDC/5 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDCMotor load (NC): 5 A at 8 VDC/5 A at 14 VDC/5 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDCMotor load (NO): 2.5 A at 8 VDC/2.5 A at 14 VDC/2.5 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC Inrush current NC: 30 A max.NO: 15 A max. Ambient temperature Operating: -10 to 80 ℃ (with no icing) Ambient humidity 35 to 95 % Permissible operating frequency Electrical: 20 operations / 1 minute max.Mechanical: 120 operations / 1 minute max. Contact resistance (Initial value) 15 mΩ max. (initial value for the built-in switch whentested alone) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength Between each terminal of the same polarities: 1,000 VAC 50/60 Hz 1 minBetween each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz 1 min Durability Electrical: 500,000 operations min.Mechanical: 10 million operations min. Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude, Contact opening: 1 ms max. at the free position and the total travel position. Shock resistance Destruction: 1,000 m/s2 max. Degree of protection IP67 Operating Force (OF) Standard value 1.96 N max. Release Force (RF) Standard value 0.39 N min. Movement Differential (MD) Standard value 3 mm max. Over-Travel (OT) Standard value 5 mm min. Operating Position (OP) Standard value 40±1 mm Free Position (FP) Standard value 51 mm max.

    Rs. 1,000.00

  • MODEL-LIMIT SWITCH ZCQ2255 MAKE OMRON

    MODEL-LIMIT SWITCH ZCQ2255 MAKE OMRON

    DELIVERY TIME : 1-2 WEEKS  Shape/Structure Enclosed Limit switches ctuator Panel mount roller plunger 11 dia. x 4.7Stainless sintered alloy roller Frequency 50/60 Hz Contact form SPDT Load General load Ratings (AC): Non-Inductive load Resistive load: 10 A at 125 VAC/10 A at 250 VACLamp load (NC): 3 A at 125 VAC/2.5 A at 250 VACLamp load (NO): 1.5 A at 125 VAC/1.25 A at 250 VACInductive load: 10 A at 125 VAC/10 A at 250 VACMotor load (NC): 5 A at 125 VAC/3 A at 250 VACMotor load (NO): 2.5 A at 125 VAC/1.5 A at 250 VAC Ratings (DC): Non-Inductive load Resistive load: 10 A at 8 VDC/10 A at 14 VDC/6 A at 30 VDC/0.5 A at 125 VDC/0.25 A at 250 VDCLamp load (NC): 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDCLamp load (NO): 1.5 A at 8 VDC/1.5 A at 14 VDC/1.5 A at 30 VDC/0.4 A at 125 VDC/0.2 A at 250 VDCInductive load: 6 A at 8 VDC/6 A at 14 VDC/5 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDCMotor load (NC): 5 A at 8 VDC/5 A at 14 VDC/5 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDCMotor load (NO): 2.5 A at 8 VDC/2.5 A at 14 VDC/2.5 A at 30 VDC/0.05 A at 125 VDC/0.03 A at 250 VDC Inrush current NC: 30 A max.NO: 15 A max. Ambient temperature Operating: -10 to 80 ℃ (with no icing) Ambient humidity 35 to 95 % Permissible operating frequency Electrical: 20 operations / 1 minute max.Mechanical: 120 operations / 1 minute max. Contact resistance (Initial value) 15 mΩ max. (initial value for the built-in switch whentested alone) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength Between each terminal of the same polarities: 1,000 VAC 50/60 Hz 1 minBetween each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz 1 min Durability Electrical: 500,000 operations min.Mechanical: 10 million operations min. Vibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude, Contact opening: 1 ms max. at the free position and the total travel position. Shock resistance Destruction: 1,000 m/s2 max. Degree of protection IP67 Classification of protection against electric shock Class II Operating Force (OF) Standard value 11.8 N max. Release Force (RF) Standard value 4.9 N min. Pre-Travel (PT) Standard value 1.5 mm max. Movement Differential (MD) Standard value 0.2 mm max. Over-Travel (OT) Standard value 3 mm min. Operating Position (OP) Standard value 47.4±0.8 mm

    Rs. 1,700.00

  • MODEL-SENSOR E2E-S05S12-WC-C12M MAKE OMRON

    MODEL-SENSOR E2E-S05S12-WC-C12M MAKE OMRON

    DELIVERY TIME : 1-2 WEEKS  Even though it is a small proximity sensor, the installation is surprisingly easy.[Features]· M4, ø5.4, ø6.5 size, non-shielded, connector relay type, connector type additions for all 108 variations· High-speed response frequency for stable detection of moving work Max. 5kHz· With four indicator lights, easy alignment of indicator lights· reduction of jig manufacturing man-hours with dedicated mounting brackets· for protection against breakage stainless steel spiral tube available (for M4, M5 use only)

    Rs. 2,400.00

  • MODEL-PLC CP2E-N60DT-D MAKE OMRON

    MODEL-PLC CP2E-N60DT-D MAKE OMRON

    DELIVERY TIME : 1-2 WEEKS  Supply voltage type DC Input type PNP/NPN Number of digital inputs 36 Output type NPN Number of digital outputs 24 Program capacity 20 K steps Data memory capacity 16 K words Logic execution time 0.23 µs Communication port(s) Ethernet TCP/IP Number of Ethernet ports 2 Number of USB ports 0 Number of RS-232 ports 0 Number of RS-485 ports 0 Communication option(s) Serial RS-232C, Serial RS-422, Serial RS-485 Number of encoder input channels 6 Max. encoder input frequency 100 kHz Max. number of PTP axes 4 Max. pulse output frequency 100 kHz Function Block programming Battery-free memory backup Real-time clock Analogue option boards Max. number of analogue I/O channels 32 Max. number of local I/O points 180 Max. number of expansion units 3 Built-in auxiliary 24 VDC output 0 mA Operating temperature range -20-60 °C Product Height (unpacked) 90 mm Product Width (unpacked) 195 mm Product Depth (unpacked) 80 mm Product Weight (unpacked) 745 g

    Rs. 22,000.00

  • MODEL-SENSOR E2E-X7D1-N-Z DC-NO TWO WIRE

    MODEL-SENSOR E2E-X7D1-N-Z DC-NO TWO WIRE

    DELIVERY TIME : 1-2 WEEKS  Proximity Sensor, Cylinder type (with screw), Sensing distance: 7 mm, Shielded, DC 2-wire, NO, Pre-wired model, Polarity, Polyurethane cable (oil resistant and reinforced), 2 m Sensing head size M18 Type Cylinder type (with screw), Shielded Power source DC 2-wire models Sensing distance 7 mm ±10% Setting distance 0 to 5.6 mm Operation mode NO

    Rs. 5,200.00

Omron

Login

Forgot your password?

Don't have an account yet?
Create account