Mitsubishi

246 products

  • MODEL-BATTERY MR-BAT 6V 1SET MITSUBISHI

    MODEL-BATTERY MR-BAT 6V 1SET MITSUBISHI

    DELIVERY PERIOD : 1-2 WEEKS  Voltage 6 V Battery Type Lithium Ion Brand Mitsubishi Model Name/Number MR-BAT6V1SET-A Battery Capacity 1650MAH MODEL: MR-BAT6V1SET-ABRAND: MITSUBISHIVOLTAGE: 6VAPPLICATION: MITSUBISHI MACHINESORIGIN: JAPAN

    Rs. 885.00

  • MODEL-PLC FX3U-48MT.ES MAKE MITSUBISHI

    MODEL-PLC FX3U-48MT.ES MAKE MITSUBISHI

    DELIVERY PERIOD : 1-2 WEEKS  Operation control system Input/output control system Programming language Program memory Max. memory capacity Built-in memory capacity/type Memory cassette (Option) Writing function during running Protection Real-time clock Clock function Kinds of instructions Basic instructions Applied instructions Processing speed Basic instructions Applied instructions No. of input/output points No. of input points No. of output points Remote I/O number of points CC-Link AnyWireASLINK AS-i Total number of points Device Input/output relay Input relay Output relay Auxiliary relay For general For keeping For keeping (battery backup fixed area) For special State Initial state For general For keeping 1 For annunciator For keeping 2 Timer (on delay) 100 ms 100 ms (for subroutine/interruption subroutine) 10 ms 1 ms accumulating type 100 ms accumulating type 1 ms Counter 16 bits up 16 bits up (keeping) 32 bits up or down 32 bits up or down (keeping) High-speed counter Data register (32 bits when paired) 16 bits for general 16 bits for keeping 16 bits for keeping (File register) 16 bits for special 16 bits for index Extension register Extension file register Pointer For branching of JUMP and CALL Input interruption and input delay interruption Timer interruption Counter interruption Nesting Constant Decimal number (K) Hexadecimal number (H) Real number (E) Character string (" ") Power supply specifications Rated voltage Allowable supply voltage range Frequency rating Allowable instantaneous power failure time Power fuse Rush current Power consumption 24 V DC service power supply 5 V DC built-in power supply Input specifications No. of input points Input connection type Input type Input signal voltage Input impedance X000 to X007 X010 or more Input signal current X000 to X007 X010 or more ON input sensitivity current X000 to X007 X010 or more OFF input sensitivity current Input response time Input signal form Input circuit insulation Indication of input operation Input circuit configuration Output specifications No. of output points Output connection type Output type External power supply Max. load Resistance load Inductive load Min. load Open circuit leakage current ON voltage Response time OFF→ON ON→OFF Insulation of circuit Indication of output operation Output circuit configuration Stored program repetitive operation system (dedicated LSI) with interruption function Batch processing system (when END instruction is executed), Input/output refresh instruction and pulse catch function are provided. Relay symbol system + step-ladder system (SFC notation possible) 64000 stepsUp to 64000 steps, including comment and file registers 64000-step (Symbolic information can be stored. Supported in Ver. 3.00 or later.)/RAM (backed up by built-in lithium battery)Battery life: Approx. 5 years [Ver. 3.00 or later]・FX3U-FLROM-1M (2000/4000/8000/16000/32000/64000 steps, loader function, symbolicinformation can be stored in the dedicated area (1300 kB).)[Ver. 2.20]・FX3U-FLROM-64L (2000/4000/8000/16000/32000/64000 steps, loader function)・FX3U-FLROM-64 (2000/4000/8000/16000/32000/64000 steps, no loader function)・FX3U-FLROM-16 (2000/4000/8000/16000 steps, no loader function) Provided (Program can be modified while the PLC is running.) Password protection provided (with entry code function) Built-in1980 to 2079 (with correction for leap year)2- or 4-digit year, accuracy within ±45 seconds/month at 25°C [Ver. 2.30 or later]・Sequence instructions: 29・Step-ladder instructions: 2[Former than Ver. 2.30]・Sequence instructions: 27・Step-ladder instructions: 2 219 kinds 498 instructions 0.065 μs/instruction 0.642 μs to several hundred μs/instruction (1) 248 points or less (Extension combined number) (1)+(2) total number of points is 256 or less. (2) 248 points or less (Extension combined number) (1)+(2) total number of points is 256 or less. (3) 256 points or less (224 points or less when the FX2N-16CCL-M is used.)*The total number of remote I/O points in CC-Link and AnyWireASLINK must be 256 points or less. (3) 128 points or less*The total number of remote I/O points in CC-Link and AnyWireASLINK must be 256 points or less. (3) 248 points or less (1)+(2)+(3) total number of points is 384 or less. (Extension combined number) X000 to X367: 248 points (octal) Extension combined number Y000 to Y367: 248 points (octal) Extension combined number M0 to M499: 500 pointsThe retentive status can be changed by parameter settings. M500 to M1023: 524 pointsThe retentive status can be changed by parameter settings. M1024 to M7679: 6656 pointsThis retentive status is a battery backup fixed area. The area characteristics cannot be changed. M8000 to M8511: 512 points S0 to S9: 10 pointsThe retentive status can be changed by parameter settings. S10 to S499: 490 pointsThe retentive status can be changed by parameter settings. S500 to S899: 400 pointsThe retentive status can be changed by parameter settings. S900 to S999: 100 pointsThe retentive status can be changed by parameter settings. S1000 to S4095: 3096 pointsThis retentive status is a battery backup fixed area. The area characteristics cannot be changed. T0 to T191: 192 points (0.1 to 3,276.7 sec) T192 to T199: 8 points (0.1 to 3,276.7 sec) T200 to T245: 46 points (0.01 to 327.67 sec) T246 to T249: 4 points (0.001 to 32.767 sec)This retentive status is a battery backup fixed area. The area characteristics cannot be changed. T250 to T255: 6 points (0.1 to 3,276.7 sec)This retentive status is a battery backup fixed area. The area characteristics cannot be changed. T256 to T511: 256 points (0.001 to 32.767 sec) C0 to C99: 100 points (Counting from 0 to 32,767)The retentive status can be changed by parameter settings. C100 to C199: 100 points (Counting from 0 to 32,767)The retentive status can be changed by parameter settings. C200 to C219: 20 points (Counting from -2,147,483,648 to +2,147,483,647)The retentive status can be changed by parameter settings. C220 to C234: 15 points (Counting from -2,147,483,648 to +2,147,483,647)The retentive status can be changed by parameter settings. [32 bits High speed up/down (keeping)]Up to 8 points can be used in range from C235 to C255.・Hardware counter1-phase: 100 kHz, 10 kHz2-phase: 50 kHz (1 edge count), 50 kHz (4 edge count)・Software counter1-phase: 40 kHz2-phase: 40 kHz (1 edge count), 10 kHz (4 edge count)There are restrictions on the points that can be used and input frequencies depending on the conditions used. D0 to D199: 200 pointsThe retentive status can be changed by parameter settings. D200 to D511: 312 pointsThe retentive status can be changed by parameter settings. D512 to D7999: 7488 points (D1000 and later can be set as file register points in 500-point units)This retentive status is a battery backup fixed area. The area characteristics cannot be changed. D8000 to D8511: 512 points V0 to V7, Z0 to Z7: 16 points [16 bits]R0 to R32767: 32768 pointsThis retentive status is a battery backup fixed area. The area characteristics cannot be changed. [16 bits]ER0 to ER32767: 32768 pointsUsable only when memory cassette is mounted P0 to P4095: 4096 points (For CJ instructions and CALL instructions, P63 jumps to END instruction) I00□ to I50□: 6 points I6□□ to I8□□: 3 points I010 to I060: 6 points (For HSCS instructions) [For master control]N0 to N7: 8 points (For MC instructions) 16 bits: -32,768 to +32,76732 bits: -2,147,483,648 to +2,147,483,647 16 bits: 0 to FFFF32 bits: 0 to FFFFFFFF 32 bits: -1.0 × 2128 to -1.0 × 2-126, 0, 1.0 × 2-126 to 1.0 × 2128Decimal-point and exponential notations are possible. Designation by characters enclosed with " "Up to 32 one-byte characters can be used for a constant in an instruction.   100 to 240 V AC 85 to 264 V AC 50/60 Hz Operation can be continued upon occurrence of instantaneous power failure for 10 ms or less.When the supply voltage is 200 V AC, the time can be change to 10 to 100 ms by editing the user program. 250 V 5 A 30 A max. 5 ms or less/100 V AC, 65 A max. 5 ms or less/200 V AC 40 WThese power consumption values are maximum values which apply to the main unit's 24 V DC service power supply when there are input/output extension blocks and special function units/blocks. 600 mA or less 500 mA or lessThe power supply is not for external use.The current capacity specified above is for the input/output extension blocks, special function blocks, special adapters and expansion boards.   24 points Removable terminal block (M3 screw) Sink/source 24 V DC ±10% X000 to X005: 3.9 kΩX006, X007: 3.3 kΩ 4.3 kΩ X000 to X005: 6 mA/24 V DCX006, X007: 7 mA/24 V DC 5 mA/24 V DC X000 to X005: 3.5 mA or moreX006, X007: 4.5 mA or more 3.5 mA or more 1.5 mA or less Approx. 10 msX000 to X017 (up to the main unit built-in number) have built-in digital filters, which can be changed to 0 to 60 ms in 1 ms increments using the application instructions or D8020.The following is applied when 0 is set.X000 to X005: 5μsX006, X007: 50μsX010 to X017: 200μs No-voltage contact inputSink: NPN open collector transistorSource: PNP open collector transistor Photocoupler insulation LED is lit when input is on   24 points Removable terminal block (M3 screw) Transistor/sink output 5-30 V DC 0.5 A or less/1 output pointThe total load current per common terminal should be the following value.1 output point/common terminal: 0.5 A or less4 output points/common terminal: 0.8 A or less8 output points/common terminal: 1.6 A or less 12 W/24 V DC - 0.1 mA or less/30 V DC 1.5 V or less Y000 to Y002: 5 μs or less/10 mA or more (5-24 V DC)Y003 or more: 0.2 ms or less/200 mA or more (at 24 V DC) Y000 to Y002: 5 μs or less/10 mA or more (5-24 V DC)Y003 or more: 0.2 ms or less/200 mA or more (at 24 V DC) Photocoupler insulation When photocoupler is driven, LED on panel is lit. Function specifications Built-in high-speed counter function 1-phase 1-count input 1-phase 2-count input 2-phase 2-count input   Built-in pulse output and positioning function Number of control axes Maximum frequency Programming language Compatible main units Pulse output instruction Positioning instruction   [C235 to C240]Up to 6 points: Up to 100 kHzWhen used High-speed comparison SET/RESET: 40 kHzWhen used High-speed zone compare HSZ: 40 - (number of instruction)[C244(OP), C245(OP)]Up to 2 points: Up to 10 kHzWhen used High-speed comparison SET/RESET: 10 kHzWhen used High-speed zone compare HSZ: 40 - (number of instruction)[C241 to C245]Up to 3 points: Up to 40 kHzWhen used High-speed comparison SET/RESET: 40 kHzWhen used High-speed zone compare HSZ: 40 - (number of instruction)When using the High-speed comparison SET/RESET, the maximum total frequency that the PLC can process (multiplied by 4 for 2-phase 4-edge counter) is 80 kHz.When using the High-speed zone compare HSZ, the total frequency processed by the PLC (multiplied by four times the input frequency for the two-phase 4-edge counter) is the maximum frequency obtained by "80 kHz - 1.5 x the number of times the HSZ instruction is used.” [C246, C248(OP)]Up to 2 points: Up to 100 kHzWhen used High-speed comparison SET/RESET: 40 kHzWhen used High-speed zone compare HSZ: 40 - (number of instruction)[C247 to C250]Up to 2 points: Up to 40 kHzWhen used High-speed comparison SET/RESET: 40 kHzWhen used High-speed zone compare HSZ: 40 - (number of instruction)When using High-speed comparison SET/RESET, the maximum total frequency that the PLC can process (multiplied by 4 for 2-phase 4-edge counter) is 80 kHz.When using High-speed zone compare HSZ, the total frequency processed by the PLC (multiplied by four times the input frequency for the two-phase 4-edge counter) is the maximum frequency obtained by "80 kHz - 1.5 x the number of times the HSZ instruction is used.” [C251, C253]Up to 2 points: Up to 100 kHzWhen used High-speed comparison SET/RESET: 40 kHzWhen used High-speed zone compare HSZ: 40 - (number of instruction) [C252, C253(OP), C254, C255]Up to 2 points: Up to 40 kHzWhenC used High-speed comparison SET/RESET: 40 kHzWhen used High-speed zone compare HSZ: 40 - (number of instruction)When using High-speed comparison SET/RESET, the maximum total frequency that the PLC can process (multiplied by 4 for 2-phase 4-edge counter) is 80 kHz.When using High-speed zone compare HSZ, the total frequency processed by the PLC (multiplied by four times the input frequency for the two-phase 4-edge counter) is the maximum frequency obtained by "80 kHz - 1.5 x the number of times the HSZ instruction is used.”   3 independent axes 100 kHz Sequence program Transistor output type main unit ・Pulse Y Output (PLSY)・Acceleration/Deceleration Setup (PLSR)Pulse output form: Pulse train (The direction is controlled with the sequence.) ・ABS Absolute current value read ([D]ABS)・DOG Search Zero Return [DSZR]・Zero Return [ZRN] (no DOG search function)Decelerates when near-point DOG is ON, Stops when near-point DOG is OFF. (This is different from the zero return operation by counting the zero point signal.)・Variable speed pulse output [PLSV]・Drive to increment [DRVI]・Drive to Absolute [DRVA]・Interrupt Positioning [DVIT]・Batch data positioning mode ([D]TBL)Pulse output form: Pulse train + direction General specifications Ambient temperature Ambient humidity Vibration resistance Installed on DIN rail Frequency: 10 to 57 Hz Frequency: 57 to 150 Hz Direct installing Frequency: 10 to 57 Hz Frequency: 57 to 150 Hz Shock resistance Noise resistance Dielectric withstand voltage Insulation resistance Grounding Working atmosphere Working altitude 0 to 55°C (32 to 131°F) when operating and -25 to 75°C (-13 to 167°F) when stored 5 to 95%RH (no condensation) when operating Half amplitude: 0.035mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)The criterion is shown in IEC61131-2. Acceleration: 4.9 m/s2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)The criterion is shown in IEC61131-2. Half amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)The criterion is shown in IEC61131-2. Acceleration: 9.8 m/s2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)The criterion is shown in IEC61131-2. 147 m/s2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and ZThe criterion is shown in IEC61131-2. By noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz Perform dielectric withstand voltage test at the following voltage between each terminals and the main unit ground terminal.Between power supply terminal (AC power supply) and ground terminal: 1.5 kV AC for 1 minBetween 24 V DC service power supply connected to input terminal (24 V DC) and ground terminal: 500 V AC for 1 minBetween output terminal (transistor) and ground terminal: 500 V AC for 1 min Perform insulation resistance test at the following voltage between each terminals and the main unit ground terminal.Between power supply terminal (AC power supply) and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance testerBetween 24 V DC service power supply connected to input terminal (24 V DC) and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance testerBetween output terminal (transistor) and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester Class D grounding (grounding resistance: 100 Ω or less)(Common grounding with a heavy electrical system is not allowed)Ground the PLC independently or jointly. Free from corrosive or flammable gas and excessive conductive dusts 2000 m or lessDo not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.

    Rs. 33,040.00

  • MODEL-ROTARY HANDLE PN F-03SV MITSUBISHI

    MODEL-ROTARY HANDLE PN F-03SV MITSUBISHI

    DELIVERY PERIOD : 1-2 WEEKS Operation handle for earth leakage breaker.[Features]· F and V type product lineup.· Meets market demand for ease of use while maintaining safety.· New product lineup with operation handle for no-fuse breaker and earth leakage breaker for less than 250 A frames.[Applications]· Optimal for breaker operation handle. Product Specifications  Part Numbers  Catalog  Features of Operation Handle for MITSUBISHI Earth Leakage Breakers F-Type Handle (MITSUBISHI Earth Leakage Breakers Mount Type) F-type handle for Earth Leakage Breakers Type mounted onto the Earth Leakage Breakers main body side. Breaker on/off operation is possible even while the door is open. It is equipped with an operation lock mechanism that enables using a padlock to lock the handle in the ON or OFF position. Specifications with breakers mounted horizontally can be made (*Excludes UL products). Protection rating (IEC60529): IP54 (*IP3X for 1,000 AF or higher, IP5X with dust-proof seal) V Type Handle (MITSUBISHI Earth Leakage Breakers Door Mount Type) V type handle for Earth Leakage Breakers Type mounting a handle on the panel door, and an operation unit on the Earth Leakage Breakers. It is equipped with an operation lock mechanism that enables using a padlock to lock the handle for Earth Leakage Breakers in the ON or OFF position. The panel depth can be adjusted using an extension shaft. Protection rating (IEC60529): IP65 S-Shaped Handle (MITSUBISHI Earth Leakage Breakers Door-Mounted Type) S-shaped handle for Earth Leakage Breakers

    Rs. 3,599.00

  • MODEL-I/O UNIT MELSEC AJ65SBTB1-32DT MITSUBISHI

    MODEL-I/O UNIT MELSEC AJ65SBTB1-32DT MITSUBISHI

    DELIVERY PERIOD : 1-2 WEEKS  Brand MITSUBISHI Model Number/Name AJ65SBTB1-32DT No. Of Channels 6 Power 100 to 120 V AC 50/60 Hz Connectors 8 Fire Load 20.4 to 26.4 V DC(ripple ratio within 5 %) Isolation 1 station 32 points assignment (use 16 points) AJ65SBTB1-32DTMITSUBISHI INPUT OUTPUT MODULECC-Link small type remote I / O unit (DC input .Remote I/O controlleMitsubishi Electric (MELSEC-A series) - 32I/O

    Rs. 16,107.00

  • MODEL-HMI-GT1675M-VTBA MAKE MITSUBISHI FOR KN-02 M/C

    MODEL-HMI-GT1675M-VTBA MAKE MITSUBISHI FOR KN-02 M/C

    DELIVERY PERIOD : 1-2 WEEKS  Series GOT1000 SERIES   Type GT16 MODEL   Power Supply (V) 100-240   Current Type AC   Display TFT   Display Colour 65536   Display Size (Inch) 10   Resolution (Pixels) 800X600   Internal Memory Capacity (MB) 15   Memory Card Slot CF   USB 2   RS-232 1   RS-422/485 1   Network Options MODBUS  PROFIBUS  MELSECNET  ETHERNET  CCLINK   Slot for Optional Cards YES   Protection Class IP67  

    Rs. 82,600.00

  • MODEL-BATTERY ER6VC119B MAKE MITSUBISHI

    MODEL-BATTERY ER6VC119B MAKE MITSUBISHI

    DELIVERY PERIOD : 1-2 WEEKS It meets or exceeds the Mitsubishi ER6V-C119B specifications defined by the Original Equipment Manufacturer but at a much lower price. Note this product can also replace: Mitsubishi ER6V C119B Mitsubishi ER6VC119B   (This is one Battery – Please verify quantity needed for your application before ordering)   BatteryGuy PLC and Industrial Computer Batteries are Manufactured to Meet or Exceed the Quality of the Original Equipment Manufacturer.  Only the Highest Grade of Materials are Used to Manufacture our Batteries, with Safety and Performance in Mind.  Please be Aware of Online Pirate Companies who Make Their Own Batteries with Insufficient Safety Circuits and Low Grade Materials.  Insufficient Circuits and Parts Can Result in a Possible Fire or Explosion in Some Cases. Chemistry: Lithium Dimensions: 0.58" Diameter x 1.98" High Connector Type: Wire Leads Connector Description: 1 Cell Lithium Battery Works With: Mistsubishi series industrial programmable logic controls Shelf Life: Approx. 10 Years Stable voltage and broad temperature range: (-60° to +85°C) Technical Specifications Voltage 3.6 Amperage 2600 mAh Dimensions L: 0.58" , H: 1.98" , W: 0.58" Product Code LS14500-MDS Availability In StockSame day shipping available Quantity in Stock 394 Weight 0.14 lbs UPC 842923102443

    Rs. 920.40

  • MODEL-BATTERY MR J3BAT AMPLIFIER MITSUBISHI

    MODEL-BATTERY MR J3BAT AMPLIFIER MITSUBISHI

    DELIVERY PERIOD : 1-2 WEEKS BRAND : MITSUBISHI   PART NO : MR-J3BAT PRODUCT TYPE : ELECTRIC LITHIUM BATTERY CONTRY OF ORIGEN : JAPAN 3.6V / 2100mAh Mitsubishi MelServo MR-J3, MR-J3-A, MR-J3-A4, MR-J3-B, MR-J3-B4, MR-J3-T and MR-J3-T4 servo amplifier absolute positioning backup battery.

    Rs. 751.66

  • MODEL-HMI MITSUBISHI GT2105-QTBDS

    MODEL-HMI MITSUBISHI GT2105-QTBDS

    DELIVERY PERIOD : 1-2 WEEKS  Mounting Type Panel Mount Control Type Touch Screen Type GT21 MODEL Display TFT Display Colour COLOR Display Size (Inch) 5.7" Resolution (Pixels) 320X240 pixels Power Supply 24V Current Type DC Protection Class IP67F Internal Memory Capacity 9MB Memory Card Slot SD USB 1 RS-232 1 RS-422/485 1 Network Options MODBUS, ETHERNET Width 164mm Height 135mm Depth 56mm Weight 0.7kg

    Rs. 44,228.76

  • MODEL-PG MITSUBISHI CARS FX2N-1PG FOR RC-01

    MODEL-PG MITSUBISHI CARS FX2N-1PG FOR RC-01

    DELIVERY PERIOD : 1-2 WEEKS Basic information Overview Pulse output: 1-axis (independent) Sales status Discontinued Discontinued date 2015/12 *Please check or inquire it in each overseas sales company site because the sale situation is different depending on each countries. Merit Pulse output block • Seven operation modes required for simple positioning control are provided.• One unit can control one axis. Up to 8 units can be connected to FX2N and FX3U PLC, up to 4 units to FX2NC PLC, and up to 7 or 8 units to FX3UC PLC to control multiple independent axes.• A max. 100 kHz pulse train can be output.• Positioning control is conducted with the sequence program. Applicable PLC Number of occupied I/O points Mass (weight) Programming language Pulse output system Pulse output form Number of control axes Maximum frequency Acceleration/deceleration process Control unit Detection of absolute position (Reads out the current value of ABS.) Positioning range Position data Power supply specifications Power supply voltage Input specifications Control input Input signal voltage STOP, DOG PG0 Input signal form Input signal current STOP, DOG PG0 Input ON sensitivity STOP, DOG PG0 Input OFF sensitivity STOP, DOG PG0 Input receiving speed DOG STOP PG0 Insulation of circuit Indication of input operation Output specifications No. of output points Output form Pulse output section (FP/RP) Rated load voltage Clear signal (CLR) Maximum load current Pulse output section (FP/RP) Clear signal (CLR) VIN current consumption Pulse output section (FP/RP) Output frequency Indication of output operation FX2N, FX3U, FX2NC, FX3UC[Connecting to the connector-type PLC]The FX2NC-CNV-IF is required to connect the FX2NC.The FX2NC-CNV-IF or FX3UC-1PS-5V is required to connect the FX3UC. Number of I/O occupied 8 points (taken from either the input or output points of the PLC) 0.3 kg Sequence program (BFM can be specified directly with the operand of the FROM/TO instruction or the applied instruction.) Open collector system Pulse train + Direction, Forward/reverse pulse train 1 independent axis 100 kHz Trapezoidal ac-/deceleration control pulse, μm, 10-4inch, mdeg Using the ABS instruction of the PLC -999,999 to +999,999 [× (Position data magnification) pulse]-999,999 to +999,999 [× (Position data magnification) μm]-999,999 to +999,999 [× (Position data magnification) × 10-4inch]-999,999 to +999,999 [× (Position data magnification) mdeg]The position data magnification sets the 1, 10,102 or 103 in parameters. 1 point (set in sequence program)   5 V DC 55 mA (internal power supply from PLC main unit)24 V DC ±10% 40 mA (External power supply)   3 points (STOP, DOG, PG0) 24 V DC 5 to 24 V DC Contact or open collector transistor 7 mA 20 mA or less 4.5 mA or more 4 mA or more 1.5 mA or less 0.5 mA or less 1 ms 4 ms 4 μs Photocoupler insulation LED is lit when input is on   3 points (FP, RP, CLR) 5 to 24 V DC (Power supplied from VIN terminal) 5 to 24 V DC 20 mA or less 20 mA or less 35 mA or less 100 kHz LED is lit when output is on General specifications Ambient temperature Ambient humidity Vibration resistance Installed on DIN rail Frequency: 10 to 57 Hz Frequency: 57 to 150 Hz Direct installing Frequency: 10 to 57 Hz Frequency: 57 to 150 Hz Shock resistance Noise resistance Dielectric withstand voltage Insulation resistance Working atmosphere Working altitude 0 to 55°C when operating and -25 to 75°C when stored 5 to 95%RH (no condensation) when operating Half amplitude: 0.035 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) Acceleration: 4.9 m/s2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) Half amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) Acceleration: 9.8 m/s2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) 147 m/s2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z By noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz Between all external terminals and ground terminal of PLC main unit: 500 V AC for 1 min Between all external terminals and ground terminal of PLC main unit: 5 MΩ or higher by 500 V DC insulation resistance tester Free from corrosive or flammable gas and excessive conductive dusts 2000 m or lessDo not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.

    Rs. 14,632.00

  • MODEL-MITSUBISHI AC SERVO MOTOR HF SP81MK-S12

    MODEL-MITSUBISHI AC SERVO MOTOR HF SP81MK-S12

    DELIVERY PERIOD : 1-2 WEEKS  Power 150 kW Type AC Voltage 109V Rated Output Capacity 750W Brand Mitsubishi Usage/Application INDUSTRIAL USE Model Name/Number HG-KR Input Phase 4.8AMP Torque 3000 RPM

    Rs. 52,510.00

  • MODEL-SERVO MOTOR HF-KP23 MAKE MITSUBISHI

    MODEL-SERVO MOTOR HF-KP23 MAKE MITSUBISHI

    DELIVERY PERIOD : 1-2 WEEKS  Motor Type AC Speed 3000rpm Voltage 111 V Power 200 W Brand Mitsubishi Usage/Application Commercial Model Name/Number Mitsubishi HF-KP23 Input Phase Three Phase Torque 1.9Nm Frequency 50 Hz IP Rating IP65 Current Rating 1.4 A

    Rs. 12,726.30

  • MODEL-SERVO MOTOR HG-SN202BJ-S100 MITSUBISHI

    MODEL-SERVO MOTOR HG-SN202BJ-S100 MITSUBISHI

    DELIVERY PERIOD : 1-2 WEEKS HG-SN152BJ $1003AC 112 V 94 A 1.5kWCONT9.3 kg CIF2000r/min 0-167Hz49 mV/min 40 CPF 92% IP67SER 090272402 209CE

    Rs. 59,554.60

Mitsubishi

Login

Forgot your password?

Don't have an account yet?
Create account