  • MODEL-E2B-SO8LS02-WP-C1 MAKE OMRON

    MODEL-E2B-SO8LS02-WP-C1 MAKE OMRON

    DELIVERY PERIOD : 1-2 WEEKS  Manufacturer OMRON  Type of sensor Inductive Output configuration NPN/NO Range 0...2mm Switch housing M8 Connection cables Lead length 2m IP rating IP67 Max. operating current 200mA Operating temperature -25...70°C Kind of forehead embedded Body material stainless steel Switching frequency max 1.5kHz Overall length 64mm

    Rs. 800.00

  • MODEL-RELAY G6A-274P 24VDC MAKE OMRON

    MODEL-RELAY G6A-274P 24VDC MAKE OMRON

    DELIVERY PERIOD : 1-2 WEEKS  Type Description Select All Category Relays , Signal Relays , up to 2Amps  Manufacturer Omron Electronics Inc-EMC Div Series G6A Packaging Tube Part Status Active Mounting Type Through Hole Coil Voltage 24VDC Contact Form DPDT (2 Form C) Contact Rating (Current) 2 A Switching Voltage 250VAC, 220VDC - Max Load - Max Switching 500VA, 440W Coil Current 8.3 mA Coil Type Non Latching Features - Termination Style PC Pin Seal Rating - Coil Insulation - Must Operate Voltage 16.8 VDC Must Release Voltage 2.4 VDC Operate Time 5 ms Release Time 3 ms Operating Temperature -40°C ~ 70°C Contact Material Silver (Ag), Gold (Au) Approval Agency - Relay Type General Purpose Grade - Qualification - Coil Resistance 2.88 kOhms Base Product Number G6A-274 Report Product Information Error View Similar

    Rs. 190.20

  • MODEL-RELAY G7SA-5A-5A 18 MAKE OMRON 24VDC

    MODEL-RELAY G7SA-5A-5A 18 MAKE OMRON 24VDC

    DELIVERY PERIOD : 1-2 WEEKS  • Additional Push-In Plus terminal sockets are used to save wiring work in comparison with traditional screw terminals.(Wiring time is reduced by 60%* in comparison with traditional screw terminals.) • Relays with forcibly guided contacts (EN 61810-3, Certified by VDE). • Supports the CE marking of machinery (Machinery Directive). • Helps avoid hazardous machine status when used as part of an interlocking circuit. • Four-pole and six-pole Relays are available. • The Relay’s terminal arrangement simplifies PWB pattern design. • Reinforced insulation between inputs and outputs. Reinforced insulation between some poles of different polarity. * According to OMRON actual measurement data Coil (4 poles)   Item Rated current (mA) Coil resistance (Ω) Max. voltage (V) Power consumption (mW) Rated voltage 12 VDC 30 400 110% Approx. 360 18 VDC 20 900 21 VDC 17.1 1,225 24 VDC 15 1,600 48 VDC 7.5 6,400 110 VDC 3.8 28,810 Approx. 420   Coil (6 poles)   Item Rated current (mA) Coil resistance (Ω) Max. voltage (V) Power consumption (mW) Rated voltage 12 VDC 41.7 288 110% Approx. 500 18 VDC 27.8 648 21 VDC 23.8 882 24 VDC 20.8 1,152 48 VDC 10.4 4,606 110 VDC 5.3 20,862 Approx. 580   Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.           2. The maximum voltage is based on an ambient operating temperature of 23°C maximum. Contacts   Load Resistive load Rated load 6 A at 250 VAC, 6 A at 30 VDC Rated carry current 6 A Max. switching voltage 250 VAC, 125 VDC Max. switching current 6 A Contact materials Au plating + Ag alloy   Characteristics Safety Relay Unit   Contact resistance *1 100 mΩ max. Operating time *2 20 ms max. Response time *3 10 ms max. Release time *2 20 ms max. Must operate voltage 75% max. Must release voltage 10% min. Maximumoperatingfrequency Mechanical 36,000 operations/h Rated load 1,800 operations/h Insulation resistance *4 1,000 MΩ min. DielectricStrength*5 *6 Between coiland contacts 4,000 VAC, 50/60 Hz for 1 min. Betweencontacts ofdifferent olarity 4,000 VAC, 50/60 Hz for 1 min. (except for followings)4 poles (for poles 3-4 in 4-pole Relays),6 poles (for poles 3-5, 4-6, and 5-6 in 6-pole Relays): 2,500 VAC, 50/60 Hz for 1 min. Betweencontacts of thesame polarity 1,500 VAC, 50/60 Hz for 1 min. Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shockresistance Destruction 1,000 m/s2 Malfunction 100 m/s2 Durability*7 Mechanical 10,000,000 operations min. (at approx. 36,000 operations/h) Electrical 100,000 operations min. (at the rated load) Inductive load switchingcapability *8(IEC60947-5-1) AC15 240 VAC, 2 ADC13 24 VDC, 1 A/48 VDC, 0.5 A/110 VDC, 0.2 A Failure rate (P level)(reference value *9) 5 VDC, 1 mA Ambient operatingtemperature *10 12 to 48 VDC: -40 to 85°C (with no icing or condensation)110 VDC: -40 to 60°C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight 4 poles: Approx. 22 g6 poles: Approx. 25 g     Note: 1. The above values are initial values.           2. Performance characteristics are based on coil temparature of 23°C.*1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.*2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not       included.*3. The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF.       Contact bounce time is included. Measurement conditions: Rated voltage operation, Ambient temperature: 23°C*4. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric       strength was measured.*5. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and       pole 6 refers to terminals 63-64.*6.When using a P7SA Socket, the dielectric strength between coil contacts/between contacts of different polarity is 2,500   VAC, 50/60 Hz for 1 min.  *7. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%. For the durability       performance to the load, refer to the Durability Curve.*8. AC15: cosφ = 0.3, DC13: L/R = 48-ms.*9. The failure rate is based on an operating frequency of 300 operations/min.*10. 12 to 48 VDC:       When operating between 70 and 85°C, reduce the rated carry current of 6 A by 0.1 A for each degree above 70°C.    (See Fig. 1.)        110 VDC:       When operating between 40 and 60°C, reduce the rated carry current of 6 A by 0.27 A for each degree above 40°C.    (See Fig. 1.)   Options (order separately) Sockets   Model Push-In Plus terminals Screw terminals PCB terminals 4 poles 6 poles 4 poles 6 poles 4 poles 6 poles P7SA-10F-ND-PU P7SA-14F-ND-PU P7SA-10F(-ND) P7SA-14F(-ND) P7SA-10P P7SA-14P Ambient operating temperature P7SA-[]F-ND(-PU): -20 to +70°CP7SA-[]F: -40 to +85°C(with no icing or condensation) -40 to +85°C(with no icing or condensation) Ambient operating humidity 25% to 85% 5% to 85% Continuous carry current 6 A *1 Dielectricstrength Between coiland contactterminals 4,000 VAC for 1 min. 2,500 VAC for 1 min. Between contactterminals ofdifferent polarity 2,500 VAC for 1 min. Between contactterminals ofsame polarity 1,500 VAC for 1 min. Insulation resistance 1,000 MΩ min. *2 Weight Approx. 58 g Approx. 70 g Approx. 44 g Approx. 59 g Approx. 9 g Approx. 10 g   *1. When operating the P7SA-[]F-ND-PU at a temperature between 50 and 70°C, reduce the continuous current       (6 A at 50°C or less) by 0.25 A for each degree above 50°C.       When operating the P7SA-[]F-ND at a temperature between 50 and 70°C, reduce the continuous current       (6 A at 50°C or less) by 0.3 A for each degree above 50°C.       When operating the P7SA-[]F at a temperature between 50 and 85°C, reduce the continuous current       (6 A at 50°C or less) by 0.1 A for each degree above 50°C.*2. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement. Short Bars (for P7SA-[]F-ND-PU)   Application Applicablesockets Models Maximumcarry current Ambient operatingtemperature Ambient operatinghumidity Crossover wiring ofcontact terminals(bottom) P7SA-[]F-ND-PU XW5S-P2.5-2[] 24 A -40 to 55°C 5% to 95% XW5S-P2.5-3[] XW5S-P2.5-4[] XW5S-P2.5-5[]   Certified Standards Safety Relay Unit EN Standards, VDE Certified   Models Ratings Standard number Certification No. Operating coil Contact ratings G7SA-2A2B 12, 18, 21, 24, 48, 110 VDC EN/IEC 61810-1Electromagnetic relay EN 61810-3Relays with forcibly guided contacts 125547 12, 18, 21, 24, 48, 110 VDC 6 A, 240 VAC (Resistive)6 A, 30 VDC (Resistive) G7SA-3A1B G7SA-3A3B G7SA-4A2B G7SA-5A1B   UL Standards Certification (File No. E41515) Industrial Control Devices   Models Category Listed/Recognized Contact ratings Operating Coil ratings G7SA-2A2B E41515 Recognized 6 A, 250 VAC (Resistive)6 A, 30 VDC (Resistive) 12, 18, 21, 24, 48, 110 VDC G7SA-3A1B G7SA-3A3B G7SA-4A2B G7SA-5A1B   CSA standard CSA C22.2 No.14 Industrial Control Devices   Models Class number File No. Contact ratings Operating Coil ratings G7SA-2A2B 3211-07 LR35535 6 A, 250 VAC (Resistive)6 A, 30 VDC (Resistive) 12, 18, 21, 24, 48, 110 VDC G7SA-3A1B G7SA-4A2B G7SA-5A1B   South Korea S-mark certified (Rated voltage 24VDC only)   Models Applicable standard number G7SA-2A2B DC24 KS C IEC 61810-1 G7SA-3A1B DC24 G7SA-3A3B DC24 G7SA-4A2B DC24 G7SA-5A1B DC24   CQC   Models Standard number Certification No. G7SA GB/T, 21711.1 CQC14002119869   Sockets CE Marking Compliance   Models EMC Directive Low Voltage Directive Machinery Directive P7SA (Excluding -P type) Not applicable Applicable Not applicable P7SA-PU Not applicable Applicable Not applicable   The CE compliance declaration was made in combination with the Safety Relay. EN Standards, VDE Certified   Models Ratings Standard number Certification No. P7SA --- EN61984 40007586   EN Standards, TÜV Certified   Models Ratings Standard number Certification No. P7SA-PU --- EN61984 R50356981   UL Standards Certification (File No. E87929) Industrial Control Devices   Models Category Listed/Recognized P7SA SWIV2 Recognized P7SA-PU SWIV2, SWIV8 Recognized   CSA standard CSA C22.2 No.14 Industrial Control Devices   Models Class number File No. P7SA 3211-07, 3211-87 LR35535 P7SA-PU 3211-07, 3211-87 LR35535  

    Rs. 1,200.00

  • MODEL-G2R-1 DC24 MAKE OMRON

    MODEL-G2R-1 DC24 MAKE OMRON

    DELIVERY PERIOD : 1-2 WEEKS  Product Attribute Attribute Value Select Attribute Manufacturer: Omron Product Category: General Purpose Relays RoHS:  Details Product: Power Relays Type: Standard Coil Voltage: 24 VDC Relay Contact Form: 1 Form C (SPDT-NO, NC) Contact Current Rating: 10 A Contact Termination: Solder Pin Mounting Style: Through Hole Switching Voltage: 380 VAC, 125 VDC Coil Termination: Solder Pin Coil Type: Non-Latching Coil Resistance: 1.1 kOhms Coil Current: 21.8 mA Contact Material: Silver Cadmium Oxide (AgCdO) Series: G2R  Length: 29 mm Width: 12.7 mm Height: 25.3 mm Brand: Omron Electronics Contact Form: SPDT (1 Form C) Power Consumption: 530 mW Product Type: General Purpose Relays Factory Pack Quantity: 100 Subcategory: Relays Part # Aliases: G2R1DC24 G2R-1-DC24-BY-OMI G2R1DC24BYOMI Unit Weight: 17 g

    Rs. 80.40

  • E2B-M18KS08-M1-B1 OMRON

    E2B-M18KS08-M1-B1 OMRON

    DELIVERY PERIOD : 1-2 WEEKS  Size M18 Mounting type Quasi-flush Sensing distance 8 mm Output type PNP Operation mode NO Connection method Connector M12 Material housing Brass, nickel plated Cable specifications - Overall length of sensor 59 mm Thread length 39 mm Degree of protection (IP) IP67

    Rs. 850.00

  • MODEL-LIMIT SWITCH OMRON D4B-2171N

    MODEL-LIMIT SWITCH OMRON D4B-2171N

    DELIVERY PERIOD : 1-2 WEEKS  Operating mechanism Snap action ctuator Top roller plunger 12.7 dia. x 4.8Stainless steel roller Frequency 50/60 Hz Contact form 1NC/1NO Load General load Ratings (AC): Non-Inductive load Resistive load: 10 A at 125 VAC/10 A at 250 VAC/10 A at 400 VACLamp load (NC): 3 A at 125 VAC/2 A at 250 VAC/1.5 A at 400 VACLamp load (NO): 1.5 A at 125 VAC/1 A at 250 VAC/0.8 A at 400 VACInductive load: 10 A at 125 VAC/10 A at 250 VAC/3 A at 400 VACMotor load (NC): 5 A at 125 VAC/3 A at 250 VAC/1.5 A at 400 VACMotor load (NO): 2.5 A at 125 VAC/1.5 A at 250 VAC/0.8 A at 400 VAC Ratings (DC): Non-Inductive load Resistive load: 10 A at 8 VDC/10 A at 14 VDC/6 A at 30 VDC/0.8 A at 125 VDC/0.4 A at 250 VDCLamp load (NC): 6 A at 8 VDC/6 A at 14 VDC/4 A at 30 VDC/0.2 A at 125 VDC/0.1 A at 250 VDCLamp load (NO): 3 A at 8 VDC/3 A at 14 VDC/3 A at 30 VDC/0.2 A at 125 VDC/0.1 A at 250 VDCInductive load: 10 A at 8 VDC/10 A at 14 VDC/6 A at 30 VDC/0.8 A at 125 VDC/0.4 A at 250 VDCMotor load: 6 A at 8 VDC/6 A at 14 VDC/4 A at 30 VDC/0.2 A at 125 VDC/0.1 A at 250 VDC Inrush current 30 A max. Conduit G1/2 (PF1/2) Earth terminal With ground terminal Ambient temperature Operating: -40 to 80 ℃ (with no icing) Ambient humidity 95 %RH max. Permissible operating speed 1 mm/s to 0.5 m/s Permissible operating frequency Electrical: 30 operations / 1 minute max.Mechanical: 120 operations / 1 minute max. Contact resistance (Initial value) 25 mΩ max. Insulation resistance Between each terminal of the same polarities: 100 MΩ min.Between each terminal and non-live-metallic part: 100 MΩ min.at 500 VDC Impulse withstand voltage Between each terminal of the same polarities: 2.5 kVBetween each terminaland ground: 4 kV Durability Electrical: 500,000 operations min. (10 A at 250 VAC)Mechanical: 30 million operations min. Vibration resistance Malfunction: 10 to 55 Hz, 0.75 mm single amplitude Shock resistance Destruction: 1000 m/s2 min.Malfunction: 300 m/s2 min. Degree of protection IP67 Classification of protection against electric shock Class I (with ground terminal) Operating Force (OF) Standard value 18.63 N max. Release Force (RF) Standard value 1.96 N min. Pre-Travel (PT) Standard value 2 mm max. Movement Differential (MD) Standard value 1 mm max. Over-Travel (OT) Standard value 5 mm min. Operating Position (OP) Standard value 48±1 mm Total Travel (TT) Reference value 7 mm Free Position (FP) Standard value 51 mm max. Direct Opening Force Standard value 49.03 N min. Direct Opening Travel Standard value 3.2 mm min.

    Rs. 2,200.00

  • MODEL- LIMIT SWITCH OMRON HL-5200

    MODEL- LIMIT SWITCH OMRON HL-5200

    DELIVERY PERIOD : 1-2 WEEKS  Product Attribute Attribute Value Select Attribute Manufacturer: Omron Product Category: Limit Switches RoHS:  Details Illuminated: Non-Illuminated Contact Form: DPST Actuator: Roller Plunger Current Rating: 5 A Voltage Rating AC: 250 VAC Voltage Rating DC: 250 VDC Operating Force: 8.83 N Termination Style: Crimp Mounting Style: Chassis Mount IP Rating: IP65 Actuator Style: Roller Plunger Brand: Omron Automation and Safety Maximum Operating Temperature: + 65 C Minimum Operating Temperature: - 5 C Product Type: Limit Switches Series: HL-5000 Factory Pack Quantity: 1 Subcategory: Switches Type: Limit Part # Aliases: HL5200 Unit Weight: 150 g

    Rs. 2,400.00

  • MODEL-GLASS RELAY DC(24V) (LY2N) OMRON

    MODEL-GLASS RELAY DC(24V) (LY2N) OMRON

    DELIVERY PERIOD : 1-2 WEEKS  Operating indicator LED Degree of protection Closed type (cover) Terminal structure Plug-in terminal Coil Coil ratings 24 VDC 36.9 mA Coil resistance 650 Ω Operate voltage (Set voltage) 80 % max. Release voltage (Reset voltage) 10 % min. Maximum voltage 110 % Power consumption Approx. 0.9 W Contact Contact rated load 10 A (Resistive load)110 VAC 7.5 A (Inductive load (cosφ = 0.4))24 VDC 10 A (Resistive load)24 VDC 5 A (Inductive load (L/R = 7 ms)) Max. contact voltage 250 VAC125 VDC Max. contact current AC: 10 ADC: 10 A Contact form DPDT Contact method Single Contact material Ag alloy Performance Contact resistance 50 mΩ max. (Voltage drop method with 5 VDC 1 A) Operating time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) Reset time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) Maximum operating frequency Mechanical: 18000 time/hourRated load: 1800 time/hour Insulation resistance Between coil and contacts: 100 MΩ min. (at 500 VDC)Between contacts of same polarity: 100 MΩ min. (at 500 VDC)Between contacts of different polarity: 100 MΩ min. (at 500 VDC) Dielectric strength Between coil and contacts: 2000 VAC 50/60 Hz 1 minBetween contacts of same polarity: 1000 VAC 50/60 Hz 1 minBetween contacts of different polarity: 2000 VAC 50/60 Hz 1 min Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude) Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude) Shock resistance (destruction) 1000 m/s2 Shock resistance (Malfunction) 200 m/s2 Endurance (Mechanical) 100 million operations min. (switching frequency 18,000 operations/h) Failure rate 100 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute) Ambient temperature (Operating) -25 to 40 ℃ (with no freezing or condensation) Ambient humidity (Operating) 5 to 85 % Weight Approx. 40 g Mounting method Socket Applicable socket PTF-08-PU/ PTF-08-PU-L/ PTF08A/ PTFZ-08-E/ PT08/ PT08QN/ PT08-0

    Rs. 270.60

  • MODEL-EE-SX670A PHOTO SENSOR MAKE OMRON

    MODEL-EE-SX670A PHOTO SENSOR MAKE OMRON

    DELIVERY PERIOD : 1-2 WEEKS  Photomicrosensor, Slot type, Through-beam, Standard, Sensing distance: 5 mm (slot width), Dark-ON/Light-ON (selectable), Indicator: No incident light, NPN output, Connector model Type Grooved Type (Standard) Luminous method Non-modulated Sensing method Through-beam type Sensing distance Slot width: 5 mm Control output (Output type) NPN open collector output Operation mode Dark-ON/Light-ON (selectable) Connection method Connector type

    Rs. 526.40

  • MODEL-PROX SWITCH E2B M12KSO4-WP-B1 OMRON

    MODEL-PROX SWITCH E2B M12KSO4-WP-B1 OMRON

    Size M12 Mounting type Quasi-flush Sensing distance 4 mm Output type PNP Operation mode NO Connection method Cable Material housing Brass, nickel plated Cable specifications PVC Cable length 2 m Overall length of sensor 47 mm Thread length 30 mm Degree of protection (IP) IP67

    Rs. 535.00

  • MODEL-LJ12A3-4-J/DZ M12 4MM AC 220V 2WIRE NC PROXIMITY SENSOR NC 220VAC RANGE 4MM DIA

    MODEL-LJ12A3-4-J/DZ M12 4MM AC 220V 2WIRE NC PROXIMITY SENSOR NC 220VAC RANGE 4MM DIA

    DELIVERY PERIOD : 1-2 WEEKS  The Inductive Proximity Sensor LJ12A3-4-Z/DX by Ouee is a robust and reliable switch designed for close proximity detection of metal objects. With a detection distance of 4mm, this sensor is crafted from durable materials such as iron, nickel, and metal, ensuring longevity and consistent performance. Ideal for various industrial applications, it provides precise and quick responses in detecting metal presence. Features: Close proximity detection of 4mm Durable construction with iron, nickel, and metal High reliability and precision Quick response time Ideal for industrial applications Compatible with metal objects Package Includes: 1 x Inductive Proximity Sensor LJ12A3-4-Z/DX Close Proximity Switch (4mm)

    Rs. 849.60

  • MODEL-EE-SX674-MAKE OMRON

    MODEL-EE-SX674-MAKE OMRON

    DELIVERY PERIOD : 1-2 WEEKS  Photomicrosensor, Slot type, Through-beam, Closemounting, Sensing distance: 5 mm (slot width), Dark-ON/Light-ON (selectable), Indicator: Incident light, NPN output, Connector model Type Grooved Type (Close-mounting) Luminous method Non-modulated Sensing method Through-beam type Sensing distance Slot width: 5 mm Control output (Output type) NPN open collector output Operation mode Dark-ON/Light-ON (selectable) Connection method Connector type